Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Huang, H. H." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
A new method of line feature generalization based on shape characteristic analysis
Autorzy:
Huang, Z.
Nie, H.
Powiązania:
https://bibliotekanauki.pl/articles/220575.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
line generalization
key point detection
shape characteristic analysis
Opis:
This paper presents a piecewise line generalization algorithm (PG) based on shape characteristic analysis. An adaptive threshold algorithm is used to detect all corners, from which key points are selected. The line is divided into some segments by the key points and generalized piecewise with the Li-Openshaw algorithm. To analyze the performance, line features with different complexity are used. The experimental results compared with the DP algorithm and the Li-Openshaw algorithm show that the PG has better performance in keeping the shape characteristic with higher position accuracy.
Źródło:
Metrology and Measurement Systems; 2011, 18, 4; 597-605
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Laser Interferometer And Vision Measurement System For Stripe Rod Calibration
Autorzy:
Zhao, M.
Huang, Q.-H.
Zhu, L.-J.
Qiu, Z.-M.
Powiązania:
https://bibliotekanauki.pl/articles/221047.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stripe edge
automatic control
laser interferometer
vision measurement
Opis:
In order to calibrate the stripe precision of a leveling rod, an automatic laser interferometer and a vision measurement system were designed by Xi’an University of Technology in China. The rod was driven by a closed-loop control and the data were collected at the stop state to ensure precision. The laser interferometer provided not only the long distance data but also a position feedback signal in the automatic control loop. CCD camera and a vision measurement method were used to inspect the stripe edge position and defect. Apixel-equivalent self-calibration method was designed to improve precision. ROI (regions of interest) method and an outline tracing method were designed to quickly extract multiple stripe edges. A combination of the image data with the interferometer data reduces control difficulty and ensures the measurement accuracy. The vision measurement method reached sub-pixel precision and the defective edges were reported. The system can automatically calibrate a stripe leveling rod with a high degree of efficiency and precision.
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 491-502
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System for Calibrating Analogue Merging Units in Absence of Synchronization Signals
Autorzy:
Cheng, H.-M.
Huang, Q.-F.
Ji, F.
Xu, Q.
Liu, J.
Tian, Z.
Powiązania:
https://bibliotekanauki.pl/articles/221084.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
intelligent substation
analogue merging unit
peer-to-peer communication
calibration system
synchronization signal
Opis:
Synchronization signals are requisite for calibrating electrical measurement devices with digital output when using conventional calibration methods. However, since the signal sampling process of the analogue merging units (MUs) operating in an intelligent substation does not rely on external synchronization signals, accuracy calibration without the use of synchronization signals is of particular importance in order to guarantee the measurement accuracy in practical situations. So far, very little research on calibration systems independent of synchronization signals has been performed. This paper presents a design of the calibration system without dependence on synchronization signals. To verify the feasibility of the proposed design, the designed system and a conventional calibration system have been employed in testing the accuracy of the same analogue MU of a 0.2 accuracy class. The comparison of the test results shows that the differences of ratio errors are below 0.02%, and the maximum difference of phase errors is about 4′. This paper also provides a new efficient and significant calibration method which does not require any external synchronization signals.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 129-138
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies