Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "infrared" wg kryterium: Wszystkie pola


Wyświetlanie 1-14 z 14
Tytuł:
Detection of human faces in thermal infrared images
Autorzy:
Kowalski, Marcin Ł.
Grudzień, Artur
Ciurapiński, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/1849135.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal infrared
face detection
biometrics
human detection
Opis:
The presented study concerns development of a facial detection algorithm operating robustly in the thermal infrared spectrum. The paper presents a brief review of existing face detection algorithms, describes the experiment methodology and selected algorithms. For the comparative study of facial detection three methods presenting three different approaches were chosen, namely the Viola-Jones, YOLOv2 and Faster-RCNN. All these algorithms were investigated along with various configurations and parameters and evaluated using three publicly available thermal face datasets. The comparison of the original results of various experiments for the selected algorithms is presented.
Źródło:
Metrology and Measurement Systems; 2021, 28, 2; 307-321
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy of drying selected products using a moisture analyzer method based on infrared radiation
Autorzy:
Janas, Sławomir
Kowalska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/27311743.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
moisture analyser
infrared heating
food quality
mass measurements
Opis:
Trueness and precision of a method for determining the water content (%) of food and chemical products based on infrared radiation with a wavelength in the range (2.70÷7.21 μm) was evaluated. The most accurate measurements for food products were obtained when the heat source was a radiant heater with a radiation wavelength of 7.21 μm, a trueness deviation of 0.01%. When heated with radiation with wavelengths (from 3.32 μm to 7.21 μm), the trueness of the measurement ranged (0.03%÷0.13%) for chemical products. The shortest analysis time for food products was found when the analysis was carried out using an IR source with a wavelength of 7.21 μm, while for chemical products, a heat source with a wavelength of 2.70÷7.21 μm was optimal. According to the results of the analysis, the use of IR radiation with a wavelength range of 3.32÷7.21 μm is an alternative for accurate measurements.
Źródło:
Metrology and Measurement Systems; 2023, 30, 2; 305--321
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An On-Line Method for Thermal Diffusivity Detection of Thin Films Using Infrared Video
Autorzy:
Dong, H.
Zheng, B.
Chen, F.
Powiązania:
https://bibliotekanauki.pl/articles/220732.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal diffusivity
on-line detection
off-centre error
infrared video
thin films
Opis:
A novel method for thermal diffusivity evolution of thin-film materials with pulsed Gaussian beam and infrared video is reported. Compared with common pulse methods performed in specialized labs, the proposed method implements a rapid on-line measurement without producing the off-centre detection error. Through mathematical deduction of the original heat conduction model, it is discovered that the area s, which is encircled by the maximum temperature curve rTMAX(θ), increases linearly over elapsed time. The thermal diffusivity is acquired from the growth rate of the area s. In this study, the off-centre detection error is avoided by performing the distance regularized level set evolution formulation. The area s was extracted from the binary images of temperature variation rate, without inducing errors from determination of the heat source centre. Thermal diffusivities of three materials, 304 stainless steel, titanium, and zirconium have been measured with the established on-line detection system, and the measurement errors are: −2.26%, −1.07%, and 1.61% respectively.
Źródło:
Metrology and Measurement Systems; 2016, 23, 1; 59-70
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of infrared thermography to non-contact testing of varistors
Autorzy:
Galla, S.
Konczakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/220473.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermography
testing
varistors
Opis:
Testing of varistors using thermography was carried out in order to assess their protective properties against possible overvoltage phenomena in the form of high-level voltage surges. An advantage of the thermography technique is non-contact temperature measurement. It was proposed to assess the properties of varistors working in electronic devices as protective elements, on the basis of estimating temperature increments on varistor surfaces, registered by an infrared camera during surge resistance tests with standard voltage levels. To determine acceptable temperature increments on a tested varistor, preliminary testing was performed of P22Z1 (Littelfuse) and S07K14 (EPCOS) type varistors, working first at a constant load and presently during surge tests,. The thermographic test results were compared with measured varistor capacity values before and after tests. It was found that recording with thermography temperature increments greater than 6°C for both P22Z1 and S07K14 varistor types detects total or partial loss of varistor protective properties. The test results were confirmed by assessment of protective properties of varistors working in output circuits of low nominal voltage devices.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 677-688
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of low frequency noise of infrared photo-detectors with transimpedance detection system
Autorzy:
Ciura, Ł.
Kolek, A.
Gawron, W.
Kowalewski, A.
Stanaszek, D.
Powiązania:
https://bibliotekanauki.pl/articles/221094.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
1/f noise
infrared detectors
nBn structure
HgCdTe heterostructures
noise measurements
transimpedance detection system
type II InAs/GaSb superlattice
Opis:
The paper presents the method and results of low-frequency noise measurements of modern mid-wavelength infrared photodetectors. A type-II InAs/GaSb superlattice based detector with nBn barrier architecture is compared with a high operating temperature (HOT) heterojunction HgCdTe detector. All experiments were made in the range 1 Hz - 10 kHz at various temperatures by using a transimpedance detection system, which is examined in detail. The power spectral density of the nBn’s dark current noise includes Lorentzians with different time constants while the HgCdTe photodiode has more uniform 1/f - shaped spectra. For small bias, the low-frequency noise power spectra of both devices were found to scale linearly with bias voltage squared and were connected with the fluctuations of the leakage resistance. Leakage resistance noise defines the lower noise limit of a photodetector. Other dark current components give raise to the increase of low-frequency noise above this limit. For the same voltage biasing devices, the absolute noise power densities at 1 Hz in nBn are 1 to 2 orders of magnitude lower than in a MCT HgCdTe detector. In spite of this, low-frequency performance of the HgCdTe detector at ~ 230K is still better than that of InAs/GaSb superlattice nBn detector.
Źródło:
Metrology and Measurement Systems; 2014, 21, 3; 461-472
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reduction of optical noise in near-infrared range laser hygrometry
Autorzy:
Stacewicz, Tadeusz
Winkowski, Mateusz
Kuk, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/2204345.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hygrometer
laser
absorption spectroscopy
optical interference
Opis:
A contactless laser hygrometer based on light absorption by H2O molecules at 1392.5 nm is described. However, measurement results can be affected by optical noise when applied to an atmospheric tunnel or glass cuvette. The noises (occurring in the form of periodic fringes in the recorded spectrum) come from unexpected interference of the light beams reflected from surfaces of the windows or other optical elements. The method of their suppression is described in this article. It is based on wavelength modulation and signal averaging over the fringes period. Also, an experiment confirming the usefulness of this method is described here.
Źródło:
Metrology and Measurement Systems; 2023, 30, 1; 169--181
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High-resolution thermal face dataset for face and expression recognition
Autorzy:
Kowalski, M.
Grudzień, A.
Powiązania:
https://bibliotekanauki.pl/articles/221388.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
face database
biometrics
thermal face recognition
infrared
face re-identification
Opis:
Development of facial recognition or expression recognition algorithms requires input data to thoroughly test the performance of algorithms in various conditions. Researchers are developing various methods to face challenges like illumination, pose and expression changes, as well as facial disguises. In this paper, we propose and establish a dataset of thermal facial images, which contains a set of neutral images in various poses as well as a set of facial images with different posed expressions collected with a thermal infrared camera. Since the properties of face in the thermal domain strongly depend on time, in order to show the impact of aging, collection of the dataset has been repeated and a corresponding set of data is provided. The paper describes the measurement methodology and database structure. We present baseline results of processing using state-of-the-art facial descriptors combined with distance metrics for thermal face re-identification. Three selected local descriptors, a histogram of oriented gradients, local binary patterns and local derivative patterns are used for elementary assessment of the database. The dataset offers a wide range of capabilities - from thermal face recognition to thermal expression recognition.
Źródło:
Metrology and Measurement Systems; 2018, 25, 2; 403-415
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of ethane, methane, formaldehyde and water vapor in the 3.33 μm range
Autorzy:
Winkowski, Mateusz
Stacewicz, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/2106414.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
infrared spectroscopy
multipass
biomarkers
trace gas sensing
Opis:
We describe construction and investigation results of optical trace gas sensor working in the 3.334-3.337 μm spectral range. Laser spectroscopy was performed with a multipass cell. A setup was elaborated for detection of ethane at the 3.3368035 μm absorption line. Analysis of the gas spectra and the experiment have shown that, beside C2H6, the sensor is suitable for simultaneous detection of methane, formaldehyde and water vapor. Due to nonlinearity of the laser power characteristic we decided to detect the fourth harmonic of signal. Additional laser wavelength modulation was applied for optical interference suppression. In result, the precision of ethane detection of approximately 80 ppt has been achieved for the averaging time of 20 seconds. Long-term stability as well as the measurement linearity have also been positively tested. The system is suitable for detecting potential biomarkers directly in human breath.
Źródło:
Metrology and Measurement Systems; 2022, 29, 2; 271--282
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
HgCdTe energy gap determination from photoluminescence and spectral response measurements
Autorzy:
Murawski, Krzysztof
Kopytko, Małgorzata
Madejczyk, Paweł
Majkowycz, Kinga
Martyniuk, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2204344.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
infrared detectors
HgCdTe
photoluminescence
spectral responsivity
semiconductor energy gap
Opis:
The temperature dependence of photoluminescence spectra has been studied for the HgCdTe epilayer. At low temperatures, the signal has plenty of band-tail states and shallow/deep defects which makes it difficult to evaluate the material bandgap. In most of the published reports, the photoluminescence spectrum containing multiple peaks is analyzed using a Gaussian fit to a particular peak. However, the determination of the peak position deviates from the energy gap value. Consequently, it may seem that a blue shift with increasing temperature becomes apparent. In our approach, the main peak was fitted with the expression proportional to the product of the joint density of states and the Boltzmann distribution function. The energy gap determined on this basis coincides in the entire temperature range with the theoretical Hansen dependence for the assumed Cd molar composition of the active layer. In addition, the result coincides well with the bandgap energy determined on the basis of the cut-off wavelength at which the detector response drops to 50% of the peak value.
Źródło:
Metrology and Measurement Systems; 2023, 30, 1; 183--194
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infrared imaging fourier transform spectrometer as the stand-off gas detection system
Autorzy:
Kastek, M.
Piątkowski, T.
Trzaskawka, P.
Powiązania:
https://bibliotekanauki.pl/articles/220556.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas detection
hyperspectral detection
imaging Fourier-transform spectrometer
stand-off detection
Opis:
The article presents the detection of gases using an infrared imaging Fourier-transform spectrometer (IFTS). The Telops company has developed the IFTS instrument HyperCam, which is offered as a short- or long-wave infrared device. The principle of HyperCam operation and methodology of gas detection has been shown in the paper, as well as theoretical evaluation of gas detection possibility. Calculations of the optical path between the IFTS device, cloud of gases and background have been also discussed. The variation of a signal reaching the IFTS caused by the presence of a gas has been calculated and compared with the reference signal obtained without the presence of a gas in IFTS's field of view. Verification of the theoretical result has been made by laboratory measurements. Some results of the detection of various types of gases has been also included in the paper.
Źródło:
Metrology and Measurement Systems; 2011, 18, 4; 607-620
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Peak detection unit for Free-Space-Optics receiver
Autorzy:
Achtenberg, Krzysztof
Mikołajczyk, Janusz
Szabra, Dariusz
Prokopiuk, Artur
Bielecki, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/221334.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
peak detection
infrared receiver module for optical communications
open path laser communications
free space optics
quantum cascade laser
Opis:
The paper presents verification of a peak detection method cooperating with infrared radiation detector module applications. The work has been divided into parts including SPICE simulations and presentation of results obtained with the constructed prototype. The design of the peak detector dedicated to applications with very short pulses requires a different approach than that for standard solutions. It is mainly caused due to the ratio of pulse width and time period. In the described application this ratio is less than 10%. The paper shows testing of an analogue circuit which is capable to be inserted in these applications.
Źródło:
Metrology and Measurement Systems; 2019, 26, 2; 377-385
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infrared devices and techniques (revision)
Autorzy:
Rogalski, A.
Chrzanowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/221154.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
frequency analysis
time-frequency analysis
short-time Fourier transform
Gabor transform
Wigner-Ville transform
Cone-Shaped Transform
wavelet analysis
time-scale analysis
wavelet decomposition
filter banks
wavelet packets
Opis:
The main objective of this paper is to produce an applications-oriented review covering infrared techniques and devices. At the beginning infrared systems fundamentals are presented with emphasis on thermal emission, scene radiation and contrast, cooling techniques, and optics. Special attention is focused on night vision and thermal imaging concepts. Next section concentrates shortly on selected infrared systems and is arranged in order to increase complexity; from image intensifier systems, thermal imaging systems, to space-based systems. In this section are also described active and passive smart weapon seekers. Finally, other important infrared techniques and devices are shortly described, among them being: non-contact thermometers, radiometers, LIDAR, and infrared gas sensors.
Źródło:
Metrology and Measurement Systems; 2014, 21, 4; 565-618
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Picosecond mode-locked tm-doped fibre laser and amplifier system providing over 20 W of average output power at 1994 nm
Autorzy:
Grześ, P.
Michalska, M.
Świderski, J.
Powiązania:
https://bibliotekanauki.pl/articles/220559.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pulsed fibre lasers and amplifiers
mid-infrared
mode-locked lasers
thulium-doped fibres
Opis:
A mode-locked Tm3+-doped fibre laser and amplifier operating at a central wavelength of 1994.3 nm is demonstrated. A thulium oscillator is passively mode-locked by a semiconductor saturable absorber mirror to generate an average power of 17 mW at a fundamental repetition rate of 81 MHz in a short linear cavity. This 2-μm laser train is amplified to an average power to 20.26 W by two double-clad thulium-doped all-fibre amplifiers. The pulse energy, duration and peak power is 250 nJ, 23 ps and 9.57 kW, respectively. This represents one of the highest values of average power at ~2-μm-wavelength for picosecond thulium-doped fibre lasers and amplifiers. The performance of the laser system is described in details.
Źródło:
Metrology and Measurement Systems; 2018, 25, 4; 649-658
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Medical image measurement and characterization: extracting mechanical and thermal stresses for surgery
Autorzy:
Lay-Ekuakille, Aimé
Ugwiri, Moise Avoci
Liguori, Consolatina
Singh, Satya P.
Rahman, Md Zia Uhr
Veneziano, Domenico
Powiązania:
https://bibliotekanauki.pl/articles/1848960.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
infrared imaging
robotic surgery
imaging for cancer detection
bioinstrumentation
laparoscopy
biomedical measurements
biomechanical and stress
Opis:
Whatever the type of surgery related to inner organs, traditional or robotic, the contact with them during surgery is a key moment for pursuing the intervention. Contacts by means of surgery instruments namely scalpels, staples, clamps, graspers, etc. are decisive moments. False, and erroneous touching and manoeuvring of organs operated on can cause irreversible damage as regard morphological aspects (outer impact) and physiological aspects (inner impact). The topic is a great challenge in the effort to measure and characterize damages. In general, electrical instruments for surgery employ the following technologies: ultrasound, radiofrequency (monopolar, and bipolar), and laser. They all result in thermal damages difficult to evaluate. The article proposes a method for a pre-screening of organ features during robotic surgery sessions by pointing out mechanical and thermal stresses. A dedicated modelling has been developed based on experimental activities during surgery session. The idea is to model tissue behaviour from real images to help surgeons to be aware of handling during surgery. This is the first step for generalization by considering the type of organ. The measurement acquisitions have been performed by means of an advanced external camera located over the surgery quadrant. The modelling and testing have been carried out on kidneys. The modelling, carried out through Comsol Multiphysics, is based on the bioheat approach. A further comparative technique has been implemented. It is based on computer vision for robotics. The findings of human tissue behavior exhibit reliable results.
Źródło:
Metrology and Measurement Systems; 2021, 28, 1; 3-21
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies