Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "system analysis" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
A thermo-hydraulic tool for automatic virtual hazop evaluation
Autorzy:
Pugi, L.
Conti, R.
Rindi, A.
Rossin, S.
Powiązania:
https://bibliotekanauki.pl/articles/220567.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
RT code prototyping
lube oil console
rotating machine HazOp analysis
transient behaviour analysis
Plant-Control System interaction
Opis:
Development of complex lubrication systems in the Oil&Gas industry has reached high levels of competitiveness in terms of requested performances and reliability. In particular, the use of HazOp (acronym of Hazard and Operability) analysis represents a decisive factor to evaluate safety and reliability of plants. The HazOp analysis is a structured and systematic examination of a planned or existing operation in order to identify and evaluate problems that may represent risks to personnel or equipment. In particular, P&ID schemes (acronym of Piping and Instrument Diagram according to regulation in force ISO 14617) are used to evaluate the design of the plant in order to increase its safety and reliability in different operating conditions. The use of a simulation tool can drastically increase speed, efficiency and reliability of the design process. In this work, a tool, called TTH lib (acronym of Transient Thermal Hydraulic Library) for the 1-D simulation of thermal hydraulic plants is presented. The proposed tool is applied to the analysis of safety relevant components of compressor and pumping units, such as lubrication circuits. Opposed to the known commercial products, TTH lib has been customized in order to ease simulation of complex interactions with digital logic components and plant controllers including their sensors and measurement systems. In particular, the proposed tool is optimized for fixed step execution and fast prototyping of Real Time code both for testing and production purposes. TTH lib can be used as a standard SimScape-Simulink library of components optimized and specifically designed in accordance with the P&ID definitions. Finally, an automatic code generation procedure has been developed, so TTH simulation models can be directly assembled from the P&ID schemes and technical documentation including detailed informations of sensor and measurement system.
Źródło:
Metrology and Measurement Systems; 2014, 21, 4; 631-648
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncertainty analysis of measuring system for instantaneous power research
Autorzy:
Dzwonkowski, A.
Swędrowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/221896.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
measuring system
metrological analysis
power measurements
measurement uncertainty
induction motor diagnostics
Opis:
The electrical power drawn by an induction motor is distorted in case of appearance of a certain type of failures. Under spectral analysis of the instantaneous power one obtains the components which are connected with definite types of damage. An analysis of the amplitudes and frequencies of the components allows to recognize the type of fault. The paper presents a metrological analysis of the measurement system used for diagnosis of induction motor bearings, based on the analysis of the instantaneous power. This system was implemented as a set of devices with dedicated software installed on a PC. A number of measurements for uncertainty estimation was carried out. The results of the measurements are presented in the paper. The results of the aforementioned analysis helped to determine the measurement uncertainty which can be expected during bearing diagnostic measurements, by the method relying on measurement and analysis of the instantaneous power of an induction machine.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 573-582
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decision Support System for Epileptogenic Zone Location During Brain Resection
Autorzy:
Kołodziej, M.
Majkowski, A.
Rak, R. J.
Rysz, A.
Marchel, A.
Powiązania:
https://bibliotekanauki.pl/articles/221787.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ECoG
iEEG
electrocorticography
epileptogenic zone
signal analysis
expert system
neural network
Opis:
This paper presents a system for locating the epileptogenic zone (EZ) using an automated analysis of electrocorticography (ECoG) signal recorded with 20 electrodes placed on the brain surface. The developed system enables automatic determination of places where anomalies connected with epilepsy are observed. The developed algorithm was tested on signals recorded for 33 patients who, after a prior neurological analysis, underwent the brain resection surgery. The results obtained with the algorithm were compared with those of medical analyses performed by the neurologist. The proposed system has a satisfactory accuracy – 87.8% – and can be used as a decision-supporting tool by the neurosurgeon during brain resection.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 15-32
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and evaluation of a needle tip measurement system based on binocular vision
Autorzy:
Lin, Yuyang
Shi, Yunlai
Zhang, Jun
Wang, Fugang
Sun, Haichao
Powiązania:
https://bibliotekanauki.pl/articles/220501.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
needle tip measurement
binocular vision system
measurement capability analysis
non-contact optical positioning
Opis:
The precise location of the needle tip is critical in robot-assisted needle-based percutaneous interventions. An automatic needle tip measuring system based on binocular vision technology with the advantages of non-contact, excellent accuracy and high stability is designed and evaluated. First the measurement requirements of the prostate intervention robot are introduced. A laser interferometer is used as the reference for measuring the position of the needle tip whose relative position variation is described as the needle tip distance in the time domain. The parameters of the binocular cameras are obtained by Zhang’s calibration method. Then a robust needle tip extraction algorithm is specially designed to detect the pixel coordinates of the needle tip without installing the marked points. Once the binocular cameras have completed the stereo matching, the 3D coordinates of the needle tip are estimated. The measurement capability analysis (MCA) is used to evaluate the performance of the proposed system. The accuracy of the system can be controlled within 0.3621 mm. The agreement analysis is conducted by the Bland-Altman analysis, and the Pearson correlation coefficient is 0.999847. The P/T ratio value is 16.42% in the repeatability analysis. The results indicate that the accuracy and stability of the binocular vision needle tip measuring system are adequate to meet the requirement for the needle tip measurement in percutaneous interventions.
Źródło:
Metrology and Measurement Systems; 2020, 27, 3; 495-512
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological Analysis of Precision of the System of Delivering a Water Capsule for Explosive Production of Water Aerosol
Autorzy:
Śmigielski, G.
Toczek, W.
Dygdała, R.
Stefański, K.
Powiązania:
https://bibliotekanauki.pl/articles/221553.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
water capsule airdrop control system
uncertainty analysis
GUM uncertainty framework
propagation of distributions
Opis:
In this paper precision of the system controlling delivery by a helicopter of a water capsule designed for extinguishing large scale fires is analysed. The analysis was performed using a numerical method of distribution propagation (the Monte Carlo method) supplemented with results of application of the uncertainty propagation method. In addition, the optimum conditions for the airdrop are determined to ensure achieving the maximum area covered by the water capsule with simultaneous preserving the precision level necessary for efficient fire extinguishing.
Źródło:
Metrology and Measurement Systems; 2016, 23, 1; 47-58
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The 8AE-PD computer measurement system for registration and analysis of acoustic emission signals generated by partial discharges in oil power transformers
Autorzy:
Witos, Franciszek
Opilski, Zbigniew
Szerszeń, Grzegorz
Setkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/220623.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
multichannel system
acoustic signal detection
acoustic signal processing
signal analysis
voltage preamplifier
Opis:
A computer measurement system, designed and built by authors, dedicated to location and description of partial discharges (PD) in oil power transformers examined by means of the acoustic emission (AE) method is presented. The measurement system is equipped with 8 measurement channels and ensures: monitoring of signals, registration of data in real time within a band of 25-1000 kHz in laboratory and real conditions, basic and advanced analysis of recorded signals. The basic analysis carried out in the time, frequency and time-frequency domains deals with general properties of the AE signals coming from PDs. The advanced analysis, performed in the discrimination threshold domain, results in identification of signals coming from different acoustic sources as well as location of these sources in the examined transformers in terms of defined by authors descriptors and maps of these descriptors on the side walls of the tested transformer tank. Examples of typical results of laboratory tests carried out with the use of the built-in measurement system are presented.
Źródło:
Metrology and Measurement Systems; 2019, 26, 2; 403-418
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies