Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Biomechanika" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Assessment of breathing movements in subjects with and without depression
Ocena wzorca oddechowego u osób zdrowych i osób z depresją
Autorzy:
Szczygieł, Elżbieta
Strzelbicki, Paweł
Karbowski, Krzysztof
Mazur, Tadeusz
Mętel, Sylwia
Golec, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1965259.pdf
Data publikacji:
2012
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
Depression
chest biomechanics
breathing patterns
depresja
biomechanika klatki piersiowej
oddychanie
wzorzec oddechowy
Opis:
Background: Breathing is a complex process. Many factors, both external and internal and also including psychological factors, influence the course of respiration. Objective: The aim of this study was to analyze the chest respiratory movements of people diagnosed with depression and those without depression.Material and methods: The research material consisted of 33 persons diagnosed with depression, being in a state of partial remission and 23 healthy subjects. The average age of the person with depression examined was 53.1 years (±8.4) and without depression 55 years (±12.6). In the group of those examined obesity or postural defects, which might affect the outcome of the study, were not found. None of the evaluated subjects were treated for respiratory diseases. To examine the respiratory movements of the chest, Respiratory Belts were used. The assessment of chest movements included: the range of the respiratory motion of the upper and lower part of the chest, the number of breathes, the number of holded breathes during inspiration, the average time of the holded breathe during inspiration, the number of holded breathes during expiration, the average time of the holded breathe during expiration. An examination of chest mobility in a standing and sitting position was carried out. The recording time was 3 minutes.Results: In patients with depression the amplitudes of chest respiratory movements were smaller. The breathe frequency was higher.Conclusions: Depression affects the breathing pattern.
Założenia: Oddychanie jest procesem złożonym. Wiele czynników zarówno zewnętrznych jak i wewnętrznych ma wpływ na jego przebieg. Są to również czynniki psychiczne.Cel: Celem prezentowanych badań była analiza ruchów oddechowych klatki piersiowej osób ze stwierdzoną depresją oraz osób bez depresji.Materiał i metoda: Badano 33 osoby (22 kobiety, 11 mężczyzn) ze zdiagnozowaną depresją w okresie częściowej remisji (śr. wiek 53,1 ±8,4 lat) oraz 23 zdrowe osoby bez depresji (15 kobiet, 8 mężczyzn) (śr. wiek 55 ±12,6 lat). U badanych osób nie stwierdzono otyłości ani wad postawy mogących mieć wpływ na wynik badań. Żadna z badanych osób nie była leczona z powodu chorób układu oddechowego. Do badań ruchów oddechowych klatki piersiowej użyto urządzenie Respiratory Belts. W ocenie ruchów klatki piersiowej uwzględniono: zakres ruchów oddechowych górnej i dolnej części klatki piersiowej, ilość oddechów, ilość wstrzymywań oddechów na wdechu, średni czas wstrzymania oddechu na wdechu, ilość wstrzymań oddechu na wydechu, średni czas wstrzymania oddechu na wydechu. Badania ruchomości klatki piersiowej przeprowadzono w pozycji stojącej i siedzącej. Czas rejestracji wynosił 3 minuty.Wyniki: U osób z depresją amplitudy ruchów oddechowych klatki piersiowej były mniejsze. Większa była też częstotliwość oddechów. Wnioski: Depresja ma wpływ na wzorzec oddechowy.
Źródło:
Medical Rehabilitation; 2012, 16(4); 8-12
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Static and dynamic examination of a locking plate in various setups for the stabilization of bone shaft fractures, including periprosthetic
Badanie statyczne i dynamiczne płytki blokowanej w różnych konfiguracjach stabilizacji złamań trzonów kości, w tym okołoprotezowych
Autorzy:
Marczyński, Wojciech
Sobolewski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1790656.pdf
Data publikacji:
2021-03-28
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
złamania okołoprotezowe
płyty blokowane
biomechanika zespoleń złamań kości
periprosthetic fractures
locking plate
biomechanics of bone fracture fixations
Opis:
Wstęp: Protezoplastyki stawu biodrowego i kolanowego, zwane niegdyś „złotym standardem” w leczeniu zniszczeń chrząstki stawowej, po okresie ich upowszechnienia, z czasem zmieniają swoje oblicze ze względu na występujące powikłania. Liczba powikłań jest wprost proporcjonalna do liczby zakładanych protez. Sytuacja taka dotyczy licznych protezoplastyk również innych stawów. Ponieważ brak jest zgodności tkankowej między metalem protezy a tkanką kostną, stanowi to negatywny element biologiczny, utrudniający zrost złamania. Cel pracy: Stanowi odpowiedź na następujące pytania: 1. Jaka jest sprężystość zespolenia płytą blokowaną w zależności od liczby wkrętów w obu odłamach, przy diastazie międzyodłamowej? 2. Jaka jest sprężystość zespolenia płytą blokowaną w zależności od liczby wkrętów w obu odłamach, przy nacisku odłam na odłam? 3. Jaka jest różnica sprężystości zespolenia z zastosowaniem „cable system” na odłamie z protezą? 4. Określenie wpływu różnych konfiguracji stabilizacji wkrętami płytki blokowanej, na miejsce szpary złamania na modelu doświadczalnym statycznym i dynamicznym; 5. Czy można uzyskać sprężystość stabilizacji stymulującej zrost kostny w zespoleniu płytowym i kiedy? Materiał i metody: Badanie wykonano w laboratorium badawczym firmy ChM. Przedmiot badania stanowiła płytka prosta blokowana firmy ChM 5,0 ChLP płytka wąska kompresyjna z ograniczonym kontaktem 15otw.L-238. Do mocowania płytki użyto wkręty blokowane 3,5 firmy ChM: 5,0ChLP wkręt samogwintujący 3,5x18T oraz 5,0ChLP wkręt samogwintujący 3,5x36T. Badanie przeprowadzono w warunkach stycznych i dynamicznych. Wyniki i wnioski: 1.Sprężystość zespolenia płytą blokowaną przy diastazie międzyodłamowej jest odwrotnie proporcjonalna do liczby wkrętów (ugięcie płyty), 2. Sprężystość zespolenia płytą blokowaną przy nacisku odłam na odłam jest odwrotnie proporcjonalna do liczby wkrętów (nacisk odłam-odłam), 3. Zastosowanie „cable system” na odłamie z protezą oraz wkrętu derotacyjnego optymalizuje sprężystość zespolenia i wydaje się optymalnym (w złamaniach okołoprotezowych), 4. Badania na modelu doświadczalnym statycznym i dynamicznym wykazały, że zespoleniem przesztywniowym/nieprzydatnym klinicznie, jest zastosowanie wkrętów we wszystkich otworach płyty, 5. sprężystość stabilizacji stymulującej zrost kostny można uzyskać w zespoleniu płytowym wspomaganym przez „cable system”.
Introduction: Hip and knee arthroplasty, formerly known as the “gold standard” in the treatment of articular cartilage damage, after a period of being highly popular, are changing the way they are perceived over time due to their related complications. The number of complications is directly proportional to the number of prostheses placed. This is the case of numerus arthroplasty surgeries, also involving other joints. Since there is no tissue compatibility between the metal prosthesis and the bone tissue, the former represents a negative biological element that hinders the healing of the fracture. Objective of the study: The study aims at addressing the following questions: 1. What is the elasticity of the fixation with a locking plate depending on the number of screws in both fragments, in the case of interfractural diastasis?, 2. What is the elasticity of the fixation with a locking plate depending on the number of screws in both fragments, in the case of fracture-on-fracture compression?, 3. What is the difference in elasticity of the fixation using the cable system on a fracture with prosthesis?, 4. Determining the influence of different stabilization setups with the locking plate screws on the spacing of the fracture on the static and dynamic experimental model, 5. Is it possible to achieve elasticity of the stabilization stimulating bone union in a plate-based fixation, and when? Material and methods: The study was performed in the research laboratory of ChM. The subject of the study was the ChM 5.0 ChLP straight narrow compression locking plate with limited contact L-238, holes-15. The plate was mounted using ChM 3.5 locking screws: 5.0 ChLP 3.5 x 18T self-tapping screw and 5.0 ChLP 3.5 x 36T self-tapping screw. The test was carried out under static and dynamic conditions. Results and Conclusions: 1. The elasticity of the fixation with a locking plate at the interfractural diastasis is inversely proportional to the number of screws (plate deflection), 2. The elasticity of the fixation with a locking plate at the fracture-on-fracture compression is inversely proportional to the number of screws (fracture-on-fracture compression), 3. Application of the “cable system” on the fracture with prosthesis and the derotation screw optimizes the elasticity of the fixation and seems to be an optimal solution (in periprosthetic fractures), 4. Studies on the experimental static and dynamic model demonstrated that placing screws in all the openings of the plate is a restrained/clinically useless fixation. 5. The elasticity of the stabilization stimulating bone union can be obtained in the plate fixation supported by the “cable system”.
Źródło:
Medical Rehabilitation; 2020, 24(4); 25-37
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Static and dynamic examination of a locking plate in various setups for the stabilization of bone shaft fractures, including periprosthetic
Badanie statyczne i dynamiczne płytki blokowanej w różnych konfi guracjach stabilizacji złamań trzonów kości, w tym okołoprotezowych
Autorzy:
Marczyński, Wojciech
Sobolewski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1790696.pdf
Data publikacji:
2021-03-28
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
periprosthetic fractures
locking plate
biomechanics of bone fracture fixations
złamania okołoprotezowe
płyty blokowane
biomechanika zespoleń złamań kości
Opis:
Introduction: Hip and knee arthroplasty, formerly known as the “gold standard” in the treatment of articular cartilage damage, after a period of being highly popular, are changing the way they are perceived over time due to their related complications. The number of complications is directly proportional to the number of prostheses placed. This is the case of numerus arthroplasty surgeries, also involving other joints. Since there is no tissue compatibility between the metal prosthesis and the bone tissue, the former represents a negative biological element that hinders the healing of the fracture. Objective of the study: The study aims at addressing the following questions: 1. What is the elasticity of the fixation with a locking plate depending on the number of screws in both fragments, in the case of interfractural diastasis?, 2. What is the elasticity of the fixation with a locking plate depending on the number of screws in both fragments, in the case of fracture-on-fracture compression? 3. What is the difference in elasticity of the fixation using the cable system on a fracture with prosthesis?, 4. Determining the influence of different stabilization setups with the locking plate screws on the spacing of the fracture on the static and dynamic experimental model, 5. Is it possible to achieve elasticity of the stabilization stimulating bone union in a plate-based fixation, and when? Material and methods: The study was performed in the research laboratory of ChM. The subject of the study was the ChM 5.0 ChLP straight narrow compression locking plate with limited contact L-238, holes-15. The plate was mounted using ChM 3.5 locking screws: 5.0 ChLP 3.5 x 18T self-tapping screw and 5.0 ChLP 3.5 x 36T self-tapping screw. The test was carried out under static and dynamic conditions. Results and Conclusions: 1. The elasticity of the fixation with a locking plate at the interfractural diastasis is inversely proportional to the number of screws (plate deflection), 2. The elasticity of the fixation with a locking plate at the fracture-on-fracture compression is inversely proportional to the number of screws (fracture-on-fracture compression), 3. Application of the “cable system” on the fracture with prosthesis and the derotation screw optimizes the elasticity of the fixation and seems to be an optimal solution (in periprosthetic fractures), 4. Studies on the experimental static and dynamic model demonstrated that placing screws in all the openings of the plate is a restrained/clinically useless fixation. 5. The elasticity of the stabilization stimulating bone union can be obtained in the plate fixation supported by the "cable system".
Wstęp: Protezoplastyki stawu biodrowego i kolanowego, zwane niegdyś „złotym standardem” w leczeniu zniszczeń chrząstki stawowej, po okresie ich upowszechnienia, z czasem zmieniają swoje oblicze ze względu na występujące powikłania. Liczba powikłań jest wprost proporcjonalna do liczby zakładanych protez. Sytuacja taka dotyczy licznych protezoplastyk również innych stawów. Ponieważ brak jest zgodności tkankowej między metalem protezy a tkanką kostną, stanowi to negatywny element biologiczny, utrudniający zrost złamania. Cel pracy: Stanowi odpowiedź na następujące pytania: 1. Jaka jest sprężystość zespolenia płytą blokowaną w zależności od liczby wkrętów w obu odłamach, przy diastazie międzyodłamowej? 2. Jaka jest sprężystość zespolenia płytą blokowaną w zależności od liczby wkrętów w obu odłamach, przy nacisku odłam na odłam? 3. Jaka jest różnica sprężystości zespolenia z zastosowaniem „cable system” na odłamie z protezą? 4. Określenie wpływu różnych konfiguracji stabilizacji wkrętami płytki blokowanej, na miejsce szpary złamania na modelu doświadczalnym statycznym i dynamicznym; 5. Czy można uzyskać sprężystość stabilizacji stymulującej zrost kostny w zespoleniu płytowym i kiedy? Materiał i metody: Badanie wykonano w laboratorium badawczym firmy ChM. Przedmiot badania stanowiła płytka prosta blokowana firmy ChM 5,0 ChLP płytka wąska kompresyjna z ograniczonym kontaktem 15otw.L-238. Do mocowania płytki użyto wkręty blokowane 3,5 firmy ChM: 5,0ChLP wkręt samogwintujący 3,5x18T oraz 5,0ChLP wkręt samogwintujący 3,5x36T. Badanie przeprowadzono w warunkach stycznych i dynamicznych. Wyniki i wnioski: 1.Sprężystość zespolenia płytą blokowaną przy diastazie międzyodłamowej jest odwrotnie proporcjonalna do liczby wkrętów (ugięcie płyty), 2. Sprężystość zespolenia płytą blokowaną przy nacisku odłam na odłam jest odwrotnie proporcjonalna do liczby wkrętów (nacisk odłam-odłam), 3. Zastosowanie „cable system” na odłamie z protezą oraz wkrętu derotacyjnego optymalizuje sprężystość zespolenia i wydaje się optymalnym (w złamaniach okołoprotezowych), 4. Badania na modelu doświadczalnym statycznym i dynamicznym wykazały, że zespoleniem przesztywniowym/nieprzydatnym klinicznie, jest zastosowanie wkrętów we wszystkich otworach płyty, 5. sprężystość stabilizacji stymulującej zrost kostny można uzyskać w zespoleniu płytowym wspomaganym przez „cable system”.
Źródło:
Medical Rehabilitation; 2020, 24(4); 25-37
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies