Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sosnowski, T." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Thermal camera system integrated into firefighter helmet
Autorzy:
Sosnowski, T.
Madura, H.
Bieszczad, G.
Kastek, M.
Powiązania:
https://bibliotekanauki.pl/articles/114130.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermal camera
observation system for a firefighter
firefighter helmet
Opis:
The paper presents a firefighter helmet with integrated thermal camera system, OLED display, sensors for monitoring the vital signs of a firefighter-rescuer and communication system for transmitting such data as live thermal video streaming, body temperature, heart rate and ambient temperature. The developed helmet, apart from its typical function as personal protection device against threats associated with firefighter’s work, also provides enhanced capability of carrying out rescue missions in low-visibility scenarios, thus increasing the safety of a firefighter itself.
Źródło:
Measurement Automation Monitoring; 2017, 63, 2; 52-56
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-function analysis of hyperspectral data
Autorzy:
Rutkowski, R.
Kastek, M.
Madura, H.
Sosnowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/114464.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hyperspectral detection
infrared imaging
spectroradiometer
Opis:
Paper is about a new method of detection and identification of gases using an infrared imaging Fourier-transform spectrometer. It’s focused on using a multi-function toolbox to get the best results possible. New interface introduces a chain of operations that allows the user to set a sequence of functions for the data analysis. It’s focused on combining methods of detection like using a sequence of filters for gases detections. Also new functions can be added by any user.
Źródło:
Measurement Automation Monitoring; 2017, 63, 2; 57-59
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermovision system for aircraft landing
Autorzy:
Sosnowski, T.
Madura, H.
Bieszczad, G.
Kastek, M.
Powiązania:
https://bibliotekanauki.pl/articles/114520.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermal imaging
thermal camera
aircraft landing support system
airport security
aircraft assistance
airport equipment
airplane detection
Opis:
The paper presents the developed multispectral optoelectronic aircraft landing assistance and data transmission system for flight control. The purpose of the system is to provide information about the landing aircraft (in the day, at night and in the haze), such as the location of the aircraft in the runway axis, altitude, distance to touchdown and the condition of the plane components like landing gear etc. The system employs two infrared cameras working in spectral range of 3-5 µm and 8-12 µm and a video camera module. The system was tested in laboratory and in the field.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 180-183
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Output signal change analysis of an uncooled microbolometer focal plane array with respect to varying control voltages and operating point temperature
Autorzy:
Ligienza, A.
Bieszczad, G.
Sosnowski, T.
Gogler, S.
Krupiński, M.
Firmanty, K.
Powiązania:
https://bibliotekanauki.pl/articles/114040.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Focal Plane Array
microbolometer
Opis:
This paper presents results of output signal analysis of uncooled microbolometric focal plane array FPA. The analysis focuses on detectors manufactured by ULIS. The signal has been tested against varying control voltages, it is blind microbolometer biasing VSK and active microbolometer biasing VFID. The working point temperature of the environment was also altered in range from 5°C to 60°C. Such analysis can be used to check the results against current mathematical model of FPA’s behavior and verify validity of the measurement method in varying working conditions. Later it could allow explore possibility to design corrective algorithms.
Źródło:
Measurement Automation Monitoring; 2018, 64, 4; 95-98
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies