Tytuł:
Characterization of surface type partial discharges using electrical, acoustic emission and UHF methods
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/114691.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
partial discharges
PD measurements
UHF method
AE method
IEC60270
transformer fault diagnosis
Opis:
This paper presents research results related to measurements of partial discharges (PD), which may occur in oil insulation systems of electric power transformers. Three measuring methods were considered: electrical (apparent charge - IEC60270), acoustic emission (AE) and ultra-high frequency (UHF) method. Research works have been proceeded under laboratory condition. PD were generated using special apparatus and spark gap configuration for surface PD modeling. Measurements were performed simultaneously for each of the regarded methods and were repeated for selected supply voltage levels. The electrical and UHF methods measurements were made using MPD measuring system from Omicron. The AE method measurements were made using a piezoelectric transducer, which was installed on the outer transformer tank wall. Comparative analysis of signals gathered during research works was made. Possibilities of application of the three considered PD detection methods for electric power systems with oil insulation were proposed in the paper.
Źródło:
Measurement Automation Monitoring; 2015, 61, 1; 12-15
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time and frequency domain analysis of partial discharges using electrical method
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/973070.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
partial discharges
electrical method
IEC 60270
frequency domain
time domain
Opis:
Partial discharge (PD) measurement results with particular consideration of time domain and frequency domain analysis of pulses generated by PD model sources are presented in the paper. Three different PD generation model sources are selected for the research: surface type, point to point and multi-point to plate. All measurements are proceeded under laboratory conditions using electrical method of a PD detection, according to the IEC60270 standard. Various amplitude and power density spectrum descriptors are proposed, as well as PD source type identification abilities on grounds of the selected descriptors are considerated. Electrical power transformers on-line PD detection and evaluation systems improvement and development are the main purpose of the presented research. Laboratory experiment results gives a solid base for further research focused on verification of the proposed methodology on a real life apparatus.
Źródło:
Measurement Automation Monitoring; 2016, 62, 2; 72-77
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies