Diagnostyka parametrów elektrycznych elektrowni wiatrowej w procesie wytwarzania energii
Diagnostics of electric parameters of energy generated by a chosen wind farm
Autorzy:
Anuszczyk, J.
Błaszczyk, P.
Terlecki, B.
Powiązania:
https://bibliotekanauki.pl/articles/1369554.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrownia wiatrowa
wind farm
Opis:
In the paper, electric energy quality measurements for the modern Kamiensk Wind Power Plant are described. The obtained results prove that each of the wind turbine is a source of a reactive power, depending on the generated value of active power. Following the conducted measurement diagnostics, it has been note that the parameters of electric energy quality in the Common Connection Point (CCP) of the power plant electric network with the public power system are guaranteed.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 2, 95; 93-98
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie małych elektrowni wiatrowych znajdujących się na terenie Politechniki Białostockiej
Comparison of the small wind power plants which are located on the Bialystok University of Technology area
Autorzy:
Kamiński, P.
Kuźma, A.
Powiązania:
https://bibliotekanauki.pl/articles/2056399.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrownia wiatrowa
odnawialne źródła energii
turbina wiatrowa
wind power plant
renewable energy sources
wind turbine
Opis:
W ramach pracy porównana zostanie efektywność wytwarzania energii elektrycznej elektrowni wiatrowych znajdujących się na terenie Politechniki Białostockiej. Porównane zostaną elektrownie wiatrowe o takich samych konstrukcjach zainstalowanych na różnych wysokościach oraz elektrownia wiatrowa z turbiną H-Darrieusa. Przedstawione zostaną wyniki uzyskane o różnych porach dnia i różnych okresach roku w zmiennych warunkach pogodowych.
Within the thesis, efficiency of generation power energy in wind power plants will be compared. The power plants are located on the area of Bialystok University of Technology. The comparison appliesto three wind power plants. Two of them are the turbines which have the same construction, but are placed in different heights. Third is the wind power plant with H-Darrieus turbine. Results measured in different times of year and various weather conditions will be prezented.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 2, 118; 101--105
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generator do konkursu „Wielkie wyzwanie: Energia”
Generator for the "Great challenge: Energy"
Autorzy:
Goryca, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/2056439.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
generator
elektrownia wiatrowa
wind power plant
Opis:
W pracy pokazano podstawowe obliczenia i konstrukcję generatora przeznaczonego do małej elektrowni wiatrowej będącej przedmiotem konkursu NCBiR „Wielkie wyzwanie: Energia”. Ograniczenia wymiarowe elektrowni narzucone w tym konkursie definiują moc generatora, zaś przyjęte rozwiązanie turbiny wiatrowej określa znamionową prędkość obrotową generatora. Napięcie wyjściowe generatora może być różne i zależy od typu ładowarki użytej do ładowania akumulatora i do zasilania pompy wody. Z uwagi na to, że NCBiR nie określił jeszcze szczegółowych danych dotyczących typu i pojemności akumulatora oraz typu, mocy i charakterystyki pompy do obliczeń uzwojenia przyjęto, że generator osiąga napięcie 24 V przy prędkości obrotowej 100 obr/min.
The paper presents the basic calculations and design of a generator for a small wind power plant which is the subject of the National Centre’s for Research and Development competition, "Great Challenge: Energy". The dimensions of the power plant specified in the competition define the generator power, and the adopted solution of the wind turbine determines the rated rotational speed of the generator. The output voltage of the generator may have different values. It depends on the type of charger used to charge the battery and supply the water pump. Since the National Centre for Research and Development has not yet provided de tailed data on the type and capacity of the battery and the type, power and characteristics of the pump, the winding was calculated for the generator reaching 24 V at 100 rpm.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2021, 1, 125; 91--94
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mała elektrownia wiatrowa z turbiną pięciołopatową
Small wind power plant with five blades turbine
Autorzy:
Goryca, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1367316.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrownia wiatrowa
prądnica
wind power plant
generator
Opis:
The paper presents the construction and parameters of small wind power plant fitted with five blades turbine of horizontal pivot. Despite its higher cost, author decided to use five blades turbine instead of three blades turbine due to its higher efficiency for light winds. The rotor is directly connected to the shaft of three-phase permanent magnet generator. Magnetic circuit of the generator is presented in the figure showing magnetic field distribution. The generator supplies one-phase converter which is directly connected to the low power system. The converter allows for transmission of energy for wide range of angular speed of the turbine. The paper also gives all volume of energy transmitted the power system in months: September, October, November of 2015 as well as maximum power generated by power plant at the wind of velocity of 12m/s. Presented power plant can be used in houses.
W artykule przedstawiono konstrukcję i parametry małej elektrowni wiatrowej wyposażonej w pięciołopatowy wirnik o poziomej osi obrotu. Pomimo większego kosztu w porównaniu z wirnikiem trójłopatowym zdecydowano się na wirnik pięciołopatowy, gdyż przy wiatrach o niewielkiej prędkości uzyskuje się z niego znacznie więcej energii. Wirnik ten umieszczony jest bezpośrednio na wale trójfazowego generatora z magnesami trwałymi, którego obwód magnetyczny pokazano na rysunku ilustrującym rozkład pola magnetycznego. Generator zasila jednofazowy falownik podłączony bezpośrednio do sieci niskiego napięcia. Falownik umożliwia przekazywanie energii do sieci w szerokim zakresie napięcia uzyskiwanego z generatora, czyli w szerokim zakresie prędkości obrotowych turbiny wiatrowej. W artykule podano łączną ilość energii przekazanej do sieci w miesiącach: wrzesień, październik i listopad 2015 roku oraz moc szczytową elektrowni uzyskaną przy wietrze o prędkości 12 m/s. Elektrownia ta może być wykorzystana w budownictwie jedno i wielorodzinnym.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 51-54
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie urządzenia pomiarowego klasy lidar dla energetyki wiatrowej
Applying lidar class measuring device for the wind power industry
Autorzy:
Radziewicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/1201901.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
energetyka wiatrowa
pomiary prędkości wiatru
mobilne urządzenie pomiarowe
LIDAR
wind energy
wind speed measurements
mobile measurement device
lidar
Opis:
In recent years the dynamic increase in installed capacity in wind power plants can be observed. In the world it comes to about 16 % per year. Making a decision about building a wind power plant is connected with the high investment risk and it requires having a number of techno– economic analyses. In the article, there is presented a possibility of applying Windcube v2 Doppler anemometer for the needs of wind energy. Mobile LIDAR measuring device Windcube v2 makes an alternative to traditional wind speed measurements with the use of measuring masts and it can effectively reduce unreliability of measurements both on the horizontal plane (landform) and vertical plane (wind speed’s profile on a specific height) what can contribute to reduction of forecasts’ uncertainty in electric energy production in a specific location. In the article, there is also presented a comparative analysis of measurements’ results in wind speed made by Windcube v2 and measurements made by met masts for the same location.
Na przestrzeni ostatnich lat zaobserwować można dynamiczny wzrost mocy zainstalowanej w elektrowniach wiatrowych, który na świecie sięga średnio około 16% rocznie. Podjęcie decyzji o budowie elektrowni wiatrowej związane jest bardzo dużym ryzykiem inwestycyjnym i wymaga przeprowadzenia szeregu analiz techniczno-ekonomicznych. W artykule zaprezentowano możliwość zastosowania anemometru Dopplerowskiego Windcube v2 na potrzeby energetyki wiatrowej. Mobilne urządzenie pomiarowe klasy LIDAR Windcube v2 stanowi alternatywę dla tradycyjnych pomiarów prędkości wiatru za pomocą masztów pomiarowych i może efektywnie zredukować niepewności pomiaru zarówno w płaszczyźnie poziomej (ukształtowanie terenu), jak i pionowej (profil prędkości wiatru na danej wysokości), co przyczynić się może do zredukowania niepewności prognozy produkcji energii elektrycznej w danej lokalizacji. W artykule także zaprezentowano analizę porównawczą wyników pomiarów przebiegu prędkości wiatru wykonanych za pomocą Windcube v2 z pomiarami wykonanymi za pomocą masztu pomiarowego dla tej samej lokalizacji.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 39-44
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wolnoobrotowy generator o mocy 500 W i małej prędkości obrotowej
Low Speed Generator with The Power of 500 W
Autorzy:
Goryca, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1368091.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
generator
moment zaczepowy
elektrownia wiatrowa
cogging torque
wind power plant
Opis:
The paper presents the design and chosen experiment results for multi-pole permanent magnet generator of the power of 500W and rated speed of 200 rpm. This generator is to cooperate with small wind turbine of vertical pivot. In spite of many rotor's poles and straight stator grooves, very low cogging torque has been obtained due to unique patented magnetic circuit. The paper also shows the image of generator prototype, the relationship between the voltage and the speed of generator at no-load mode, the realationship between the voltage and the load of generator at the rated speed and mesurement results for cogging torque. This generator can also be applied in micro wind and hydrology power plant.
W artykule przedstawiono konstrukcję i wybrane wyniki badań wielobiegunowego generatora z magnesami trwałymi o mocy 500 W i prędkości znamionowej 200 obr/min. Generator ten ma współpracować z niewielką turbiną wiatrową o pionowej osi obrotu. Dzięki obwodowi magnetycznemu o unikalnej, opatentowanej konstrukcji uzyskano bardzo mały moment zaczepowy pomimo dużej liczby biegunów wirnika i pomimo prostych żłobków stojana. W artykule pokazano konstrukcję wirnika i stojana oraz widok wykonanego prototypu prądnicy, przedstawiono zależność napięcia od prędkości obrotowej dla biegu jałowego oraz zależność napięcia od obciążenia dla prędkości znamionowej, a także wyniki pomiarów momentu zaczepowego. Generator może być także stosowany w mikroelektrowniach wodnych i wiatrowych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 1, 105; 63-66
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektywności wytwarzania energii elektrycznej w elektrowni wiatrowej z poziomą osią obrotu
Efficiency valuation of electrical power generation in wind power plant with horizontal axis of rotation
Autorzy:
Kamiński, P.
Kuźma, A.
Powiązania:
https://bibliotekanauki.pl/articles/2056398.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrownia wiatrowa
odnawialne źródła energii
turbina wiatrowa z poziomą osią obrotu
wind power plant
renewable energy sources
wind turbine with a horizontal axis of rotation
Opis:
Celem pracy jest ocena efektywności wytwarzania energii elektrycznej w elektrowni wiatrowej o poziomej osi obrotu usadowionej na dachu budynku INNO-EKO-TECH Politechniki Białostockiej. Istotą badań jest próba określenia wpływu różnych czynników środowiskowych na pracę turbiny, obserwacja jej pracy o różnych porach dnia i różnych okresach roku w zmiennych warunkach pogodowych. Przedmiotem badań jest mała elektrownia wiatrowa z trójfazową prądnicą synchroniczną o mocy znamionowej 5 kW.
The main purpose of the thesis is to evaluate efficiency of generation electrical energy in the wind power plant with horizontal axis of rotation, lokated on the roof of Bialystok University of Technology building INNO-EKO-TECH. The essence of the research is to define influence of various environmental aspects to the work of the turbine, observation of its activity at different times of the day and periods of the year, in varying weather conditions. The object of the resea rch is a small wind power plant with three-phase synchronous generator of 5 kW nominal power.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 2, 118; 95--99
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Complete power electronics converter for small wind turbine with asynchronous generator
Kompleksowy przekształtnik energoelektroniczny do małej turbiny wiatrowej z generatorem indukcyjnym
Autorzy:
Gajowik, T.
Możdżyński, K.
Malinowski, M.
Rafał, K.
Powiązania:
https://bibliotekanauki.pl/articles/1199253.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
wind energy integration
AC-AC converters
integracja energii wiatru
przekształtniki AC-AC
Opis:
W artykule przedstawiono kompleksowe rozwiązanie przeznaczone do automatyzacji oraz integracji z siecią elektroenergetyczną małej turbiny wiatrowej z generatorem indukcyjnym o regulowanej prędkości. Zaprezentowano strukturę systemu i omówiono szczegółowo przekształtnik energoelektroniczny AC-DC-AC wraz z obwodami pomocniczymi. Pokazano wyniki działania prototypowego układu o mocy 10 kW.
This paper presents a complete solution for automation and grid integration of a small wind turbine with variable speed asynchronous generator. Structure of a system is presented and AC-DC-AC power electronic converter with its auxiliary circuits is discussed in detail. Results of the 10 kW prototype system operation are illustrated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 3, 115; 71-76
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy bezpieczeństwa pracy w elektrowniach wiatrowych i słonecznych
Occupational safety problems in wind and solar power stations
Autorzy:
Dąbrowski, M.
Dąbrowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1199512.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
occupational safety
wind farms
solar power plants
bezpieczeństwo pracy
elektrownie wiatrowe
elektrownie słoneczne
Opis:
The number of users of wind and solar power stations in Poland, who are exposed to especially mechanical and electrical hazards at the service of these objects still increases. The performed analysis showed that during the use of these power stations appear faultinesses especially concerning accessions to workplaces and evacuation ways, personal protective equipment, issuing of orders in writing and also elaboration of instructions and job processing. Different type severe damages and employment injuries are present thereby. In the article one talked over chosen safety rules during typical jobs in these objects. Attention has been paid that high qualified and properly trained operators are required to use of these objects. They should pass special medical examinations and be equipped with professional tools and protective equipment. Authors hope that advices presented in the article will help the selection of preventives for the purpose of work safety improvement in wind and solar power stations.
Stale wzrasta liczba użytkowników elektrowni wiatrowych i słonecznych w Polsce narażonych na zagrożenia zwłaszcza mechaniczne i elektryczne występujące przy obsłudze tych obiektów. Przeprowadzone analizy wykazały, że podczas użytkowania elektrowni występują nieprawidłowości dotyczące zwłaszcza dojść do stanowisk pracy i dróg ewakuacyjnych, środków ochrony indywidualnej, wydawania pisemnych poleceń, a także opracowania instrukcji i wykonywania prac. Ich skutkiem są różnego typu groźne awarie i wypadki przy pracy. W artykule omówiono wybrane zasady bezpieczeństwa postępowania podczas typowych prac w tych obiektach. Zwrócono uwagę, że do obsługi i użytkowania tych obiektów wymagani są wysoko wykwalifikowani i odpowiednio przeszkoleni pracownicy. Powinni oni przejść specjalistyczne badania lekarskie i być wyposażeni w specjalistyczny sprzęt oraz wyposażenie ochronne. Autorzy liczą, że przedstawione w artykule wskazania wspomogą dobór środków prewencji w celu poprawy bezpieczeństwa pracy w elektrowniach wiatrowych i słonecznych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 2, 114; 25-31
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generator do elektrowni wiatrowej o pionowej osi obrotu
Generator for Vertical Axis Wind Turbine
Autorzy:
Goryca, Z.
Mazur, D.
Powiązania:
https://bibliotekanauki.pl/articles/1368423.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrownia wiatrowa
generator
analiza termiczna
moment zaczepowy
wind turbine
thermal analysis
cogging torque
Opis:
The paper presents the construction and chosen results of test for generator of the power of 2kW and rotational speed of 180 rev/min destined for small wind power plant of vertical axis. Turbine of the type H-Darrieus having low rotational speed and cogging torque was applied in the power plant. Therefore the generator has to have low cogging torque allowing for start-up of power plant and low rotational Speer adjusted to turbine speed. During the process of the generator construction, new patented methods allowing for minimization of cogging torque and all available methods decreasing its mass were used. Chosen results of test for generator show relationship between output voltage of generator and its rotational speed and additionally presents the output voltage waveform. Presented generator has low mass, high efficiency and extremely low cogging torque.
W artykule przedstawiono konstrukcję i wybrane wyniki badań generatora o mocy 2 kW i prędkości obrotowej 180 obr./min. przeznaczonego do małej elektrowni wiatrowej o pionowej osi obrotu. W elektrowni zastosowano turbinę typu H-Darrieus charakteryzującą się małą prędkością obrotową i niską wartością momentu rozruchowego. Z tego względu generator musi mieć mały moment zaczepowy ułatwiający rozruch elektrowni i małą prędkość obrotową dostosowaną do prędkości turbiny. Przy konstruowaniu generatora wykorzystano nowy, opatentowany sposób minimalizacji momentu zaczepowego oraz zastosowano wszystkie możliwe zabiegi zmniejszające jego masę. Wybrane wyniki badań obrazują zależność napięcia wyjściowego generatora od prędkości obrotowej i od obciążenia oraz przedstawiają kształt tego napięcia. Opracowany generator charakteryzuje się małą masą, dużą sprawnością oraz niezwykle małym momentem zaczepowym.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 133-137
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarys rozwoju elektrowni wiatrowych
Outline of the development of wind power plant
Autorzy:
Szymczak, P.
Prajzendanc, P.
Łosiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1201664.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
energetyka wiatrowa
etapy rozwoju
generator
pionierzy
turbina
wind energy
stages of development
pioneers
turbine
Opis:
The paper discusses the outline of the historical development of wind power on land and sea and provides brief biographical data of selected artists and pioneers in the field. Periodization proposed development of electric generators and wind turbines. Specific steps briefly characterized. In the following paper discusses the current state of wind energy, both worldwide and in Poland and presents the projected scenarios of its development in the European Union and Poland. A summary of the work finalized.
W pracy omówiono zarys historyczny rozwoju elektrowni wiatrowych na lądzie i morzu oraz zamieszczono krótkie dane biograficzne wybranych pionierów i twórców w tej dziedzinie. Zaproponowano periodyzację rozwoju generatorów elektrycznych i elektrowni wiatrowych. Poszczególne etapy pokrótce scharakteryzowano. W dalszej części pracy omówiono obecny stan energetyki wiatrowej zarówno na świecie jak i w Polsce oraz przedstawiono prognozowane scenariusze jej rozwoju w Unii Europejskiej i Polsce.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 4, 112; 201-207
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmiany liczby biegunów stojana na wybrane parametry funkcjonalne w bezżłobkowym generatorze tarczowym
Influence of Changing a Number of Stator Poles on the Integral Parameters in the Slotless Axial Flux Generator
Autorzy:
Młot, A.
Łukaniszyn, M.
Powiązania:
https://bibliotekanauki.pl/articles/1368208.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
generator turbiny wiatrowej
generator tarczowy
stojan bezżłobkowy
wind power generator
axial flux generator
slotless stator
Opis:
Design of axial-flux generators with magnets is a part of an on-going energy storage research project for wind energy applications. In this paper axial flux one-phase small power prototype of a generator with magnets is analysed. The prototype is modified to three-phase models and the number of stator poles are changed as well. The presented machines consist of slotless stator cores which are made of lamination. Electromagnetic requirements for axial-flux electric machines are achieved by doing three-dimensional finite element analyses. A three-dimensional analysis is necessary due to the nature of arrangement coils such as endwinding effect. The main goal of the electromagnetic field investigation is the achieved high induced rectifier DC voltage from the three phase winding and high efficiency.
W artykule przedstawiono analizę wybranych parametrów funkcjonalnych prototypu jednofazowego generatora o strumieniu osiowym, przeznaczonego do zastosowania w bardzo małej elektrowni wiatrowej. W generatorze zastosowano stosunek liczby biegunów stojana do wirnika równy 8/8. Celem pracy było sprawdzenie parametrów elektromechanicznych generatora i wygenerowanie wystarczającej wartości napięcia w uzwojeniu stojana, zdolnej do naładowania baterii połączonych szeregowo akumulatorów. W tym celu opracowano trójwymiarowy model obliczeniowy oparty na metodzie elementów skończonych (MES) a następnie zweryfikowano pomiarowo wyniki obliczeń. Model obliczeniowy posłużył do wykonania modyfikacji generatora, która polegała na zwiększeniu stosunku liczby biegunów stojana do liczby biegunów wirnika do 9/8, 12/8 i 24/8. We wszystkich zmodyfikowanych wersjach generatora zwiększono liczbę faz do trzech. Dla każdej opracowanej wersji generatora wykonano analizę mocy, sprawności oraz momentu elektromagnetycznego.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 3, 100/1; 169-175
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulator poziomu obciążenia małej elektrowni wiatrowej
Regulator for Wind Turbine Generator
Autorzy:
Pakosz, A.
Goryca, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1368384.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
regulator obciążenia
elektrownia wiatrowa
podgrzewanie wody
wind power plant controller
heaters
warming the water up
Opis:
Controller being based on AtMega microcontroller allowing for control the load of wind Power plant of 3kW has been designed. Its aim is to adjust the load to the power provided by wind power plant. The device measures the current and voltage, calculates the power and switches the proper load on. Heaters warming the water up were used as the load of the power plant. The controller allows for remote control via Ethernet. Messages concerning the status and malfunctions of the power plant are sent as sms to the chosen number of mobile phone. The controller is fitted with the over-speed circuit and detection of heater blown. The basic parameters such as: current, voltage, power, generator speed and wind speed are presented and recorded in operator terminal.
Sterownik do regulacji obciążenia elektrowni wiatrowej o mocy 3kW opracowano w oparciu o mikrokontroler AtMega. Jego zadaniem jest dostosowanie obciążenia do mocy dostarczanej przez generator. Układ dokonuje pomiaru prądu oraz napięcia, oblicza moc i załącza odpowiednie obciążenie. W charakterze odbiornika energii zastosowano grzałki podgrzewające wodę. Regulator posiada możliwość zdalnej kontroli poprzez sieć Ethernet. Komunikaty o stanie pracy i awarii mogą być wysyłane w formie sms’a na ustalony numer telefonu. Sterownik wyposażono w zabezpieczenia przed przekroczeniem granicznej prędkości generatora oraz detekcję przepalenia którejkolwiek grzałki. Podstawowe parametry jak: prąd, napięcie, moc, prędkość generatora i prędkość wiatru są prezentowane i archiwizowane w panelu operatorskim.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 129-131
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eksperymentalna elektrownia solarno - wiatrowa
Experimental wind – solar hybrid power system
Autorzy:
Polak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1367798.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrownia słoneczna
elektrownia wiatrowa
tracker dwuosiowy
moduł fotowoltaiczny
solar power
wind power
biaxial tracker
photovoltaic module
Opis:
In the article the author presents his own experiences and observations related to the conversion system operation of the solar and wind energy into electricity. Wind – solar hybrid power system that has been built is composed of three segments: the first segment of a small wind turbine with a rated power PN = 3,5 kW, the second segment consists of polycrystalline PV modules with a maximum power P = 750 Wp installed on a fixed frame, the third segment is composed of polycrystalline PV modules with a maximum power P = 750 Wp installed on biaxial tracker, which follows the sun in the horizontal and vertical planes. All segments of the wind – solar hybrid power system is equipped with independent measuring systems, which allows, among others, separate registration of the energy produced by each segment.
W artykule autor przedstawił własne doświadczenia i obserwacje związane z eksploatacją ww. systemu konwersji energii słonecznej i wiatrowej na elektryczną. Zainstalowana minielektrownia złożona jest z trzech segmentów: • segment pierwszy to mała elektrownia wiatrowa o mocy znamionowej PN = 3,5 kW, • segment drugi składa się z polikrystalicznych modułów fotowoltaicznych o mocy maksymalnej P = 750 Wp, zainstalowanych na nieruchomym stelażu, • segment trzeci składa się polikrystalicznych modułów fotowoltaicznych o mocy maksymalnej P = 750 Wp, zainstalowanych na trackerze dwuosiowym podążającym za słońcem w płaszczyznach poziomej i pionowej. Wszystkie segmenty elektrowni są wyposażone w niezależne układy pomiarowe, umożliwiające m.in. rejestrację ilości wyprodukowanej przez nie energii.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 2, 106; 235-237
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prądnica wzbudzana magnesami trwałymi z dzielonym uzwojeniem twornika
Permanent magnet generator with split armature winding
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Rossa, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2056370.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrownia wiatrowa
prądnica synchroniczna
magnesy trwałe
uzwojenie twornika
wind farm
synchronous generator
permanent magnets
armature winding
Opis:
Elektrownia wytwarza więcej energii elektrycznej, jeśli turbina wiatrowa i sprzęgnięty z nią generator synchroniczny pracują z prędkością obrotową dostosowaną do prędkości wiatru według kryterium maksymalnej mocy. Napięcie prądnicy powinno być możliwie duże zarówno przy małej prędkości obrotowej jak i przy prędkości znamionowej. Uzyskuje się to poprzez podzielenie uzwojenia twornika prądnicy na sekcje i łączenie sekcji uzwojenia, w czasie pracy prądnicy, szeregowe bądź równoległe. W artykule przedstawiono prądnicę wzbudzaną magnesami trwałymi z uzwojeniem twornika podzielonym na dwie sekcje i trzy sekcje. Sekcje uzwojenia są łączone wyłącznikami elektromechanicznymi. Sterownik mikroprocesorowy mierzy parametry pracy prądnicy: napięcie, prąd, częstotliwość i steruje załączaniem i wyłączaniem wyłączników.
The power plant generates more electricity if the wind turbine and the synchronous generator associated with it operate at a speed adapted to the wind speed according to the maximum power criterion. The generator voltage should be as high as possible at both low speed and rated speed. This is achieved by dividing the generator armature winding into sections and connecting the winding sections, during generator operation, in series or in parallel. The article presents a permanent magnet generator with armature winding divided into two sections and three sections. Winding sections are connected by electromechanical switches. The microprocessor controller measures the generator's operating parameters: voltage, current, frequency and controls the switching on and off of circuit breakers.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 3-4, 123-124; 45--49
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies