Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "machine vibration" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Asymetria obciążenia generatora wzbudzanego magnesami trwałymi źródłem drgań
Load asymmetry of PM generator as a vibration source
Autorzy:
Barański, M.
Powiązania:
https://bibliotekanauki.pl/articles/1199545.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
electrical machine
permanent magnets
diagnostics
vibration
maszyna elektryczna
magnesy trwałe
diagnostyka
drgania
Opis:
An influence of load asymmetry of PM generator for the generation of vibrations in the tested machine is described in this article. There is shown mathematical model, simulation and laboratory test results. The waveforms of torque and current and frequency analysis for simulations and laboratory tests are presented in the paper. The mathematical equation – a marker for this disruption is presented in the summary. This is the subject of patent application.
W artykule przedstawiono wpływ asymetrii obciążenia generatora ze wzbudzeniem pochodzącym od magnesów trwałych na generację drgań w rozpatrywanej maszynie. W pracy przedstawiono model matematyczny asymetrycznie obciążonej maszyny z magnesami trwałymi, wyniki symulacji komputerowych wykonanych w programie Ansys Maxwell 2D oraz wyniki badań laboratoryjnych. Autor przedstawił przebiegi czasowe momentu oraz prądu wraz z analizą częstotliwościową – zarówno dla symulacji, jak również badań laboratoryjnych. Dodatkowo przedstawiono przebiegi czasowe przyspieszenia drgań dla symetrycznego oraz asymetrycznego obciążenia generatora. W podsumowaniu przedstawiono również autorskie równanie matematyczne, które stanowi pewnego rodzaju marker dla rozpatrywanego zjawiska. Pozwala ono na podstawie analizy częstotliwościowej sygnału własnego maszyny je zdiagnozować. Metoda diagnostyczna bazująca na przedstawionej zależności jest przedmiotem zgłoszenia patentowego.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 2, 114; 51-55
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zasilania silnika pm na wzrost poziomu wibracji maszyny – diagnostyka na podstawie analizy częstotliwościowej sygnałów własnych
Supply asymmetry of PM motor as a vibration source - diagnostics based on frequency analysis of own signals
Autorzy:
Barański, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1196814.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyna elektryczna
magnesy trwałe
diagnostyka
drgania
electrical machine
permanent magnets
diagnostics
vibration
Opis:
An influence of supply asymmetry of PM motor for the generation of vibrations in the tested machine is described in this article. There are shown mathematical model and laboratory test results. The waveforms of torque and current and frequency analysis for laboratory tests are presented in the paper. The waveforms of vibration speed for idle run and load state are also presented. The mathematical equation – a marker for this disruption is presented in the summary. The method was patented.
W artykule przedstawiono wpływ asymetrii zasilania silnika ze wzbudzeniem pochodzącym od magnesów trwałych na generację drgań w rozpatrywanej maszynie. W pracy przedstawiono model matematyczny asymetrycznie zasilanej maszyny z magnesami trwałymi oraz wyniki badań laboratoryjnych. Autor przedstawił przebiegi czasowe momentu oraz prądu wraz z analizą częstotliwościową. Dodatkowo przedstawiono przebiegi czasowe prędkości drgań dla symetrycznego oraz asymetrycznego zasilania silnika – zarówno dla biegu jałowego, jak również dla stanu obciążenia. W podsumowaniu przedstawiono również autorskie równanie matematyczne, które stanowi pewnego rodzaju marker dla rozpatrywanego zjawiska. Umożliwia to jego zdiagnozowanie na podstawie analizy częstotliwościowej sygnału własnego. Metoda diagnostyczna bazująca na przedstawionej zależności została opatentowana.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 1, 121; 117-120
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Maszyna elektryczna z magnesami trwałymi czujnikiem drgań
Permanent magnet electrical machine as a vibration sensor
Autorzy:
Barański, M.
Polak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1367972.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyna elektryczna
magnesy trwałe
diagnostyka
drgania
electrical machine
permanent magnets
diagnostics
vibration
Opis:
The paper presents a vibration diagnostic method designed for diagnose of permanent magnets (PM) machines. Those machines are commonly used in electrical vehicles, small wind and water power systems. Specific structural properties of machines excited by permanent magnets are used in this method - electromotive force (EMF) generated due to vibrations. In this article several issues will be discussed: the method genesis, the similarity of permanent magnet machines to vibration sensor and results of simulation and laboratory tests.
W artykule zaprezentowano zarys metody diagnostycznej dedykowanej dla maszyn z magnesami trwałymi. W metodzie tej wykorzystuje się specyficzne właściwości konstrukcyjne maszyn ze wzbudzeniem od magnesów trwałych tj. indukowanie się składowej periodycznej SEM pod wpływem czynników zewnętrznych np. drgań. W artykule opisano genezę powstania metody oraz przedstawiono wyniki symulacji komputerowych i badań laboratoryjnych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 2, 106; 65-68
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ asymetrii obciążenia generatora wzbudzanego magnesami trwałymi na zmianę poziomu drgań
An influence of pm generator load asymmetry for vibration level
Autorzy:
Barański, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2142544.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyna elektryczna
magnesy trwałe
diagnostyka
drgania
electrical machine
permanent magnets
diagnostics
vibration
Opis:
W artykule przedstawiono wpływ asymetrii obciążenia generatora ze wzbudzeniem pochodzącym od magnesów trwałych na zwiększenie poziomu drgań. W pracy przedstawiono, wyniki symulacji komputerowych oraz badań laboratoryjnych. Autor przedstawił przebiegi czasowe momentu oraz prądu wraz z analizą częstotliwościową – zarówno dla symulacji, jak również badań laboratoryjnych. Przedstawiono również autorskie równanie matematyczne, które stanowi pewnego rodzaju marker dla rozpatrywanego zjawiska.
An influence of load asymmetry of PM generator for the generation of vibrations in the tested machine is described in this article. There are shown simulation and laboratory test results. The waveforms of torque and current and frequency analysis for simulations and laboratory tests are presented in the paper. The mathematical equation – a marker for this disruption is presented in the summary.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 67--70
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bezczujnikowa diagnostyka wibracyjna maszyn z magnesami trwałymi bazująca na sygnałach własnych
Sensorless vibration diagnostic of pm machines based on the own signals
Autorzy:
Barański, M.
Powiązania:
https://bibliotekanauki.pl/articles/1367283.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyna elektryczna
magnesy trwałe
diagnostyka
drgania
electrical machine
permanent magnets
diagnostics
vibration
Opis:
Majority of electrical machines vibration diagnostic is based on measurements which are done with external sensors connected to dedicated for this purpose complicated and expensive meters or analyzers. The main advantage of the described method of detecting vibrations in electrical machines with permanent magnets is that the measurement system does not require to use an external sensors for measuring vibration. Excitation circuit and armature winding perform a function of the vibration sensor at the same time. Specific structural properties of machines excited by permanent magnets are used in this method - electromotive force (EMF) generated due to vibrations. PM machine is similar to electro-dynamic sensor of vibration. In the sensor permanent magnet moves inside the coil and generates a voltage on terminals of the coil. The voltage signal is proportional to vibrations. In the PM machine, the rotor with permanent magnets generated the EMF if is exposed to the vibrations. The supply is no required for the sensor and machine. The sensitivity depends on the number of turns in the coil in both of cases. The method based on frequency analysis of voltage or current of tested machine. This analysis allows to determine the frequency closely related to increased level of vibration, excited a particular undesirable state of the machine. Description of method was the aim of “Vibroacoustic diagnostic method of traction permanent magnets motors and generators based on the own signals“ project realized in LIDER program.
Większość badań mających na celu detekcję drgań w maszynie elektrycznej opiera się głównie na wykorzystaniu zewnętrznych czujników wraz z dedykowaną, skomplikowaną aparaturą. Dlatego największą zaletą opisywanej w artykule metody diagnostycznej jest to, że układ pomiarowy nie potrzebuje zewnętrznych czujników drgań. Magnesy trwałe oraz uzwojenie pełnią równocześnie funkcję czujnika drgań. Sposób diagnostyki wykorzystuje specyficzne właściwości konstrukcyjne maszyn z magnesami trwałymi, tj. indukowanie się SEM pod wpływem wibracji. Jest to podyktowane tym, że maszyna elektryczna ze wzbudzeniem od magnesów trwałych jest bardzo podobna do elektrodynamicznego czujnika drgań, którego działanie opiera się na tym, że pod wpływem drgań przemieszczający się magnes, indukuje napięcie wewnątrz cewki zależne od poziomu wibracji. W maszynie PM, wirnik z magnesami trwałymi pod wpływem drgań generuje SEM w uzwojeniu. Zarówno czujnik, jak i maszyna do generacji sygnału pomiarowego nie potrzebują zewnętrznych źródeł zasilania. Czułość układu w obu przypadkach jest zależna od ilości zwojów uzwojenia. Metoda opiera się na tym, iż przebieg napięcia, bądź prądu maszyny poddaje się analizie częstotliwościowej, która pozwala na określenie częstotliwości ściśle związanych ze zwiększeniem się poziomu drgań wzbudzonych konkretnym stanem niepożądanym w maszynie. Opracowanie metody było celem projektu „Wibroakustyczna metoda diagnostyczna silników trakcyjnych i generatorów z magnesami trwałymi na podstawie sygnałów własnych” realizowanego w ramach programu LIDER.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 111-116
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensorless vibration diagnostics of permanent magnet generators – the unbalance example
Bezczujnikowa diagnostyka drganiowa generatorów z magnesami trwałymi – przykład niewywagi
Autorzy:
Barański, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2056360.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
pomiary drgań
generator z magnesami trwałymi
diagnostyka
akwizycja danych
analiza danych
maszyna elektryczna
vibration measurement
permanent magnet generator
diagnostics
data acquisition
data analysis
electrical machine
Opis:
This paper presents a new vibration diagnostic method designed for diagnose of permanent magnets (PM) generators. Those machines are commonly used in small wind, water systems and electrical vehicles. The described method is very innovative and unique. Specific structural properties of machines excited by permanent magnets are used in this method - electromotive force (EMF) generated due to vibrations. In this article several issues will be discussed: the method genesis, the similarity of permanent magnet machines to vibration sensor, mathematical model, and results of simulation and laboratory tests. The method of determination the technical condition of PM electrical machine basing on its own signals is the subject of patent application.
Praca przedstawia zastosowanie wibracyjnej metody diagnostycznej dla generatorów z magnesami trwałymi pracujących w stanach asymetrii obciążenia. Maszyny te są wykorzystywane w małych elektrowniach wiatrowych oraz wodnych. Opisywana metoda jest innowacyjna i unikalna. Wykorzystuje ona specyficzne właściwości konstrukcyjne maszyn z magnesami trwałymi, tj. indukowanie się SEM pod wpływem wibracji. W pracy przedstawiono min. podobieństwo maszyny z magnesami trwałymi do czujnika drgań, zawarto wyniki obliczeń, symulacji oraz badań laboratoryjnych. Metoda ta jest przedmiotem zgłoszenia patentowego.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 3-4, 123-124; 11--14
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increased vibration level caused by asymmetric loading in PM generators
Problem zwiększonego poziomu wibracji, którego przyczyną jest asymetryczne obciążenie generatorów wzbudzanych magnesami trwałymi
Autorzy:
Barański, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2056361.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
pomiary drgań
generator z magnesami trwałymi
diagnostyka
akwizycja danych
analiza danych
maszyna elektryczna
vibration measurement
permanent magnet generator
diagnostics
data acquisition
data analysis
electrical machine
Opis:
The paper presents a new vibration diagnostic method designed for permanent magnets (PM) generators with point operation asymmetry. Those machines are commonly used in small wind or water systems. The described method is very innovative and unique. Specific structural properties of machines excited by permanent magnets are used in this method - electromotive force (EMF) generated due to vibrations. In this article several issues will be discussed: the similarity of permanent magnet machines to vibration sensor, calculations, results of simulation and laboratory tests. The method is the subject of patent application.
Praca przedstawia zastosowanie wibracyjnej metody diagnostycznej dla generatorów z magnesami trwałymi pracujących w stanach asymetrii obciążenia. Maszyny te są wykorzystywane w małych elektrowniach wiatrowych oraz wodnych. Opisywana metoda jest innowacyjna i unikalna. Wykorzystuje ona specyficzne właściwości konstrukcyjne maszyn z magnesami trwałymi, tj. indukowanie się SEM pod wpływem wibracji. W pracy przedstawiono mn. podobieństwo maszyny z magnesami trwałymi do czujnika drgań, zawarto wyniki obliczeń, symulacji oraz badań laboratoryjnych. Metoda ta jest przedmiotem zgłoszenia patentowego.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 3-4, 123-124; 1--6
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies