Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "AC Machines" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Comparison of different methods for excitation of synchronous machines
Autorzy:
Schmuelling, S.
Kreischer, Ch.
Gołȩbiowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1367718.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
AC machines
Brushless machines
Electromagnetic transients
Excitation system
Power system simulation
Opis:
The energy turnaround in Germany leads to new operating conditions for small and medium synchronous generators. Since the electricity generation through renewable energy sources, such as wind or photovoltaic, is highly volatile, generators have to run up from standstill into rated operation within several minutes. Hence, it is necessary to compensate a lack of electricity generation caused by wrong weather forecasts. Usually, gas turbine systems provide this possibility. The generator is used as a starter engine due to the connection to a frequency inverter. The excitation current is often provided by static excitation systems. Thus, it is possible to start from standstill and run up the drive until the gas turbine is able to generate a positive torque. A new excitation concept, based on an induction machine with a 3-phase rotor winding, is able to provide an excitation current at 0 rpm and eliminates the need for brushes. To verify the applicability for power systems, both systems are compared under different aspects. The control of the excitation current at different speeds and the possibility to settle shaft oscillations after electrical faults are aspects researched in the paper at hand. A power system simulation is performed with a synchronous machine connected to a grid. Both excitation systems are modeled by equivalent circuit diagrams in Matlab Simscape.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 89-93
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykrywanie defektów rdzeni maszyn prądu przemiennego metodą skanowania magnetycznego
Faults Detection in the Stator Core of AC Electric Machines by Magnetic Scanning Method
Autorzy:
Rad, M.
Rams, W.
Kandora, W.
Powiązania:
https://bibliotekanauki.pl/articles/1368509.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
izolacja blach
badania diagnostyczne prądem zmiennym
electrical machines
stator core insulation
AC diagnostic tests
Opis:
The classic method of detecting faults in metal stators of electrical machines is based on the excitation of a circular magnetic field in the iron, and the observation of the temperature distribution on the inner surface of the iron. This method, however, have significant drawbacks: high excitation current requiring high-power sources, a few hours the time needed to obtain reliable results. There are other methods based on the measurement of the magnetic field at the surface of the iron. A typical device is ELCID system. For each pair of teeth is obtained one value in the position, on the length of the stator. In practice, a more precise definition of the fault place is needed, comparable to the infrared method. Another method for measuring the magnetic field at the surface of iron by the electronic sensors have been developed. The applied head has a spatial resolution of about 10 mm. Measurements and necessary calculations and visualization of the results are carried out by a dedicated computer program.
Tradycyjna metoda wykrywania zwarć blach w stojanach maszyn elektrycznych prądu przemiennego, polega na wzbudzeniu kołowego pola magnetycznego w żelazie i obserwacji rozkładu temperatur na wewnętrznej powierzchni żelaza. Metoda ta posiada jednakże istotne wady: duża wartość prądu wzbudzającego i potrzebna moc źródła, kilkugodzinny czas potrzebny do otrzymania wiarygodnych wyników. Stosowane są więc inne metody oparte na pomiarze pola magnetycznego przy powierzchni żelaza. Typowym urządzeniem jest system ELCID. Dla każdej pary zębów otrzymuje się jedną wartość w danym miejscu na długości stojana. Wymaganiem praktyki kontroli jest bardziej precyzyjne określenie miejsca zwarcia blach, porównywalne z metoda termowizyjną. Opracowano inny sposób pomiaru pola magnetycznego przy powierzchni żelaza, czujnikami elektronicznymi. Wykorzystywana głowica ma rozdzielczość przestrzenną wyników około 10 mm. Pomiary i niezbędne obliczenia oraz wizualizacja wyników realizowane są przez dedykowany program komputerowy.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 131-134
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies