Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "industrial water" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Physico-chemical treatment of waste water contaminated with heavy metals in the industry of metallic coatings
Fizykochemiczne oczyszczanie ścieków zanieczyszczonych metalami ciężkimi w przemyśle metalowym
Autorzy:
Valencia, Jacipt A.R.
González, Jordi P.
Jimenez-Pitre, Iris
Molina-Bolívar, Geomar
Powiązania:
https://bibliotekanauki.pl/articles/947151.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
coagulation-flocculation
heavy metals
industrial waste water
metallic coatings
precipitation
galwanizowanie
koagulacja/flokulacja
metale ciężkie
ścieki przemysłowe
wytrącanie
Opis:
This investigation was undertaken to determine the optimum conditions for physical-chemical treatment of waste water contaminated with heavy metals in the industry of metallic coatings. The industry uses substances such as: inorganic acids, alkalis, acidic and alkaline metal salts, that has a high water demand in the processes of flushing and cleaning the parts to be coated. According to the preliminary characterization of samples and reported in the literature theory, physico-chemical process was implemented for the removal of contaminants that consisted in chemical oxidation of CN-ions, followed by chemical precipitation made next to a coagulation/flocculation and subsequent adsorption on activated coal. Laboratory scale tests showed the optimal conditions of treatment including chemical oxidation by the addition of 4.15 cm3 of H2O2 (30%) per gram of CN, chemical precipitation with NaOH to a pH of 12, followed by coagulation/flocculation with Fe2(SO4)3 at a speed of 135 rpm for 3 min and 20 rpm for 20 min and finally the addition of 1.0 g of adsorbent previously activated at 700°C. From this study, it is clear that the adsorption on activated carbon is highly efficient in the removal of heavy metals from industrial waste water from electroplating. However, it is also clear that the parallel application of the treatments, shown here, is more effective to completely remove contaminants such as lead, nickel, silver, and copper at laboratory scale, so it is recommended the simultaneous use of these physico-chemical processes.
Badania podjęto celem ustalenia optymalnych warunków fizycznego i chemicznego oczyszczania ścieków z galwanizerni. Zakłady takie wykorzystują kwasy nieorganiczne, alkalia i sole metali o odczynie kwasowym bądź zasadowym. Ponadto zużywają one dużo wody w procesie oczyszczania i płukania pokrywanych metalami elementów. Na podstawie wstępnej charakterystyki próbek i danych literaturowych wdrożono fizyczny i chemiczny proces usuwania zanieczyszczeń, który polegał na chemicznym utlenianiu jonów CN oraz chemicznym wytrącaniu, koagulacji/flokulacji oraz adsorpcji na węglu aktywnym. Testy w skali laboratoryjnej wykazały, że optymalne warunki oczyszczania obejmowały chemiczne utlenianie dzięki dodatkowi 4,15 cm3 H2O2 (30%) na gram CN, chemiczne strącanie NaOH do pH 12, a następnie koagulację/ flokulację z prędkością 135 obr.∙min–1 przez 3 min i 20 obr.∙min–1 przez 20 min oraz dodatek 1,0 g adsorbentu aktywowanego wstępnie w 700°C. Badania wykazały, że adsorpcja na węglu aktywnym jest wysoce efektywna w usuwaniu metali ciężkich ze ścieków galwanizerskich. Równoległe stosowanie zabiegów przedstawionych w pracy zapewnia jeszcze większą efektywność w całkowitym usuwaniu ołowiu, niklu, srebra i miedzi w skali laboratoryjnej. Dlatego równoczesne stosowanie tych zabiegów jest zalecane w praktyce.
Źródło:
Journal of Water and Land Development; 2019, 43; 171-176
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health implications of stream water contamination by industrial effluents in the Onitsha urban area of Southeastern Nigeria
Autorzy:
Okafor, Uchenna P.
Obeta, Michael C.
Ayadiuno, Romanus U.
Onyekwelu, Anthony C.
Asuoha, Godson C.
Eze, Eberechukwu J.
Orji-Okafor, Chetachi E.
Igboeli, Emeka E.
Powiązania:
https://bibliotekanauki.pl/articles/1844374.pdf
Data publikacji:
2021
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
contamination
health implication
industrial effluents
Onitsha urban
stream water
Opis:
Nigeria has abundant surface and ground water resources many of which are polluted and can be detrimental to human health when consumed. This study investigated the effects of effluents discharged by industries into streams on the health of people who depend on stream water for domestic purposes in the Onitsha urban area of eastern Nigeria. Water samples collected from eleven discharge locations underwent physico-chemical and microbiological analyses. Data on the effects of industrial effluents on health were obtained from records in the public hospitals located in Onitsha as well as through questionnaire surveys and field observations. The results of the analyses revealed that the effluents grossly degrade surface water bodies; several parameters (temperature, iron, dissolved oxygen, turbidity, biological oxygen demand, chemical oxygen demand, lead, magnesium, total heterotrophic counts, total coliform group, pH) had values which were higher than the WHO (2011) safety limits for drinking water. The contamination of investigated streams by effluents had negative impact on the health of stream users. The discussion included health effects of polluted water and the prevalence of water borne or related diseases in the area. Implications of these findings were also discussed. Management measures capable of minimizing contamination of surface water in the study area were suggested.
Źródło:
Journal of Water and Land Development; 2021, 48; 105-114
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of discharged industrial effluents on the parameters of surface water in Onitsha urban area, southeastern Nigeria
Wpływ zrzucanych ścieków przemysłowych na parametry wód powierzchniowych na obszarze miejskim Onitsha w południowowschodniej Nigerii
Autorzy:
Obeta, Michael C.
Okafor, Uchenna P.
Nwankwo, Cletus F.
Powiązania:
https://bibliotekanauki.pl/articles/293086.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
drinking water supplies
industrial effluents
streams contamination
water quality
jakość wody
ścieki przemysłowe
zanieczyszczenie strumieni
źródła wody pitnej
Opis:
Chemical industries in Onitsha urban area of southeastern Nigeria have been discharging large quantities of effluents into surface streams. These streams are the primary sources of water used by poor households for domestic purposes. This study examines the effects of effluents on the physicochemical and microbiological characteristics of the recipient streams. This objective was achieved by collecting eight effluents and twenty-two water samples from control points, discharge locations and exit chutes of the effluents for analysis. The results of the study characterised the effluents and their effects on the recipient streams. The effluents cause gross pollution of the streams as most of the parameters including pH, total dissolved solids (TDS), turbidity, biological oxygen demand (BOD), chemical oxygen demand (COD), Mg, NO3, Fe, Cu, Pb, Cr, total heterotrophic count (THC) and total coliform group (TCG) returned high values that exceeded the World Health Organisation’s (WHO) benchmark from 2011 for drinking water quality. Only dissolved oxygen (DO), Na, Zn, Ca, and Na returned values lower than the WHO guideline. E. coli was found in all the samples; TCG was also high. This paper, therefore, recommends that the effluent generating industries should treat their effluents before disposal.
Przemysł chemiczny na obszarze miejskim Onitsha w południowowschodniej Nigerii odprowadza duże ilości ścieków do strumieni. Strumienie te są podstawowym źródłem wody dla ubogich gospodarstw domowych. W pracy analizowano wpływ ścieków przemysłowych na fizyczne, chemiczne i mikrobiologiczne właściwości wody w strumieniach. Cel ten osiągnięto, pobierając próby wody do analiz z 8 odpływów, z 22 punktów kontrolnych i miejsc zrzutu. Wyniki charakteryzują odpływy i ich wpływ na wody odbiornika ścieków. Zrzuty ścieków powodowały znaczne zanieczyszczenie strumieni, ponieważ większość parametrów (pH, zawiesiny, mętność, BZT, ChZT, Mg, NO3, Fe, Cu, Pb, Cr, suma bakterii heterotroficznych, bakterie grupy coli) przekraczała normy jakości wody pitnej ustalone przez WHO w 2011 r. Jedynie stężenie rozpuszczonego tlenu, Na, Zn, Ca i Na spełniały te normy. Obecność E. coli stwierdzano we wszystkich próbkach, duże były także wartości stężenia bakterii grupy coli. Zaleca się, aby zakłady przemysłowe poddawały ścieki oczyszczaniu przed ich zrzutem do strumieni.
Źródło:
Journal of Water and Land Development; 2019, 42; 136-142
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies