Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pollution" wg kryterium: Temat


Tytuł:
Phosphorus load concentration in tropical climates reservoir for each water quantity class
Ładunek fosforu i zdolność do samooczyszczania zbiorników wodnych w warunkach tropikalnych według klas ilości wody
Autorzy:
Marselina, M.
Burhanudin, M.
Powiązania:
https://bibliotekanauki.pl/articles/292977.pdf
Data publikacji:
2018
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
phosphorus pollution
pollution load
reservoir
water quality
jakość wody
ładunek zanieczyszczeń
zanieczyszczenie fosforem
zbiornik
Opis:
Saguling Reservoir has a potential to be used as a raw water supply for Bandung Metropolitan Area (BMA), with the discharge of 1.622 dm·s–1. However, further studies are needed to ensure that the water quality is in accordance with the government regulations. This study shows that the reservoir’s P concentration was 315.0 mg·m–3 on average in 1999–2013. This value only meets the class III of government standards of water quality for the cultivation of freshwater fish, livestock, and to irrigate landscaping, but does not belong to the class I standard of 200 mg·m–3 for drinking water. The total-P concentration in wet, normal, and dry years was 796.3, 643.8, and 674.8 mg·m–3, respectively. The pollution load was highest in wet years due to the high levels of sediment. The pollution load of the reservoir did not exceed the class III classification of 29 405.01 kg·year–1. The pollution load in wet, normal, and dry years was 38 790.1, 25 991.9, and 23 929.0 kg·year–1, respectively. The phosphorus pollution is caused by the use of floating net cages in the reservoir, which makes it difficult to meet the standards. In wet years, the pollution load was higher than in normal and dry years. The P load could be higher in the wet season due to dilution and could probably decrease the pollutant concentration in the reservoir.
Zbiornik Saguling z wielkością odpływu sięgającą 1622 dm3·s–1 może być źródłem wody dla zespołu miejskiego Bandung. Niezbędne są jednak badania, by stwierdzić, czy jakość wody spełnia krajowe normy. W przedstawionych badaniach wykazano, że średnie stężenie fosforu w latach 1999–2013 wynosiło 315,0 mg·m–3. Ta wielkość mieści się w III klasie rządowych norm i jest odpowiednia do chowu i hodowli ryb, pojenia zwierząt i nawadniania. Nie spełnia jednak norm I klasy (200 mg·m–3) dla wody pitnej. Stężenie całkowitego fosforu w latach wilgotnych, normalnych i suchych wynosiło odpowiednio 796,3, 643,8, i 674,8 mg·m–3. Ładunek zanieczyszczeń był najwyższy w latach wilgotnych z powodu dużej ilości osadów dennych. Ładunek zanieczyszczeń doprowadzanych do zbiornika nie przekraczał normy dla III klasy równej 29 405,01 kg·rok–1.W latach wilgotnych, normalnych i suchych ładunki te wynosiły odpowiednio 38 790,1, 25 991,9 i 23 929.0 kg·rok–1. Zanieczyszczenie fosforem spowodowane jest używaniem pływających sadzów na ryby, co utrudnia osiągnięcie norm jakościowych. Ładunek fosforu mógł być wyższy w deszczowej porze roku z powodu dużej ilości wody, co prawdopodobnie było przyczyną mniejszego stężenia zanieczyszczeń w zbiorniku.
Źródło:
Journal of Water and Land Development; 2018, 36; 99-104
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The variability of pollution load of organic, biogenic and chromium ions in wastewater inflow to the treatment plant in Nowy Targ
Zmienność ładunku zanieczyszczeń organicznych, biogennych oraz jonów chromu w ściekach dopływających do oczyszczalni w Nowym Targu
Autorzy:
Bugajski, P. M.
Nowobilska-Majewska, E.
Kurek, K.
Powiązania:
https://bibliotekanauki.pl/articles/292364.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
chromium ions
organic and biogenic pollution
pollution load
wastewater
jony chromu
ładunek zanieczyszczeń
ścieki
zanieczyszczenia biogenne
zanieczyszczenia organiczne
Opis:
The aim of the study was to analyze the mean daily wastewater load from the corporate wastewater treatment plant in Nowy Targ. The study analyzed the wastewater load expressed by BOD5, COD, total nitrogen (Ntot), total phosphorus (Ptot) and chromium ions (Cr). The study was conducted from 2006 to 2016, in which 591 samples of raw wastewater were collected and analyzed in a control well before the treatment plant with a mean of 4 times a month. The scope of research in the analytical part covered the variability of wastewater loads in individual years and determined the characteristic values of mean daily load in particular months. Mean daily wastewater load for BOD5 – 7 053 kg·d–1 for COD – 23 437 kg·d–1 for total nitrogen – 1 464 kg·d–1 for total phosphorus – 197 kg·d–1 and for chromium ions – 129 kg·d–1. For each of the analyzed index, it was found that in the each months mean daily wastewater load in raw wastewater is variable. In the analyzed period the mean daily discharged wastewater oscillated within 13 924 m3·d–1, which accounted for about 66% of the projected load.
Celem pracy jest analiza wartości średnich dobowych ładunków zanieczyszczeń dopływających w ściekach surowych do zbiorczej oczyszczalni w Nowym Targu. W pracy poddano analizie zanieczyszczenia wyrażone wskaźnikami BZT5, ChZT, azotu ogólnego (Nog), fosforu ogólnego (Pog) oraz ładunkiem jonów chromu (Cr). Badania prowadzono w okresie od 2006 do 2016 roku, w którym pobrano i poddano analizie 591 próbek ścieków surowych pobranych w studzience kontrolno-pomiarowej przed oczyszczalnią ze średnią częstością 4 razy w miesiącu. W części analitycznej zakresem badań objęto zmienność ładunków zanieczyszczeń w poszczególnych latach oraz określono charakterystyczne wartości średniego dobowego ładunku w poszczególnych miesiącach. Na podstawie przeprowadzonej analizy stwierdzono, że średni dobowy ładunek wyrażony BZT5 wyniósł 7 053 kg∙d–1, ChZT – 23 437 kg∙d–1, ładunek azotu ogólnego – 1 464 kg∙d–1, fosforu ogólnego – 197 kg∙d–1 i jonów chromu – 129 kg∙d–1. W odniesieniu do każdego z analizowanych wskaźników stwierdzono, że w poszczególnych miesiącach średni dobowy ich ładunek w ściekach surowych jest zmienny. W analizowanym okresie średni dobowy dopływ ścieków oscylował w granicach 13 924 m3∙d–1, co stanowiło około 66% obciążenia projektowanego.
Źródło:
Journal of Water and Land Development; 2017, 35; 11-17
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Kishnica mines on pollution of the Graçanka River and water wells nearby, Kosovo
Autorzy:
Kadriu, Sadija
Sadiku, Milaim
Kelmendi, Mensur
Aliu, Mehush
Mulliqi, Ismet
Hyseni, Arbër
Powiązania:
https://bibliotekanauki.pl/articles/1844372.pdf
Data publikacji:
2021
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
mines
pollution
Graçanka River
water quality
water wells
Opis:
Mining is an important economic activity in Kosovo. Artana and Kishnica mines are a part of the Trepça industrial complex and the increased exploitation of deposits has resulted in undesirable impact on the environment around the mining sites. More specifically, the mining activity caused water pollution. The aim of the study was to assess the physico-chemical parameters and presence of heavy metals (Ni, Zn, As, Cd, Pb, Cr, Mn, Fe) in water samples of the Graçanka River and household wells in the area. The Inductively Coupled Plasma-Mass Spectrometer (ICP-MS) was used to determine metal concentrations. Samples were collected from five sites along the Graçanka River and from four private water wells during a period from September to November 2019. Concentrations of heavy metals in the Graçanka River were as follows Mn (24–1203 μg∙dm–3), Fe (11–785 μg∙dm–3), Ni (4–299 μg∙dm–3), Pb (2–22 μg∙dm–3), As (1–5 μg∙dm–3), Zn (344–1646 μg∙dm–3), Cr (1–2 μg∙dm–3) and Cd (<1 μg∙dm–3). The well waters were polluted by multiple metals (Mn > Fe > Ni > Pb) with concentrations of Mn 1834–36089 μg∙dm–3, Fe 158–3535 μg∙dm–3, Ni 82–1882 μg∙dm–3, Pb 5–45 μg∙dm–3, As 2–19 μg∙dm–3, Cd 1–12 μg∙dm–3, Zn 979–23474 μg∙dm–3 and Cr 1–2 μg∙dm–3. The pollution has been caused by industrial (mining-related) and urban discharges. The contamination originates from the release of flotation process waste and from the leaching of the tailings dam. Most probably, rainwater has washed contaminants into the aquifers and the Graçanka River. River water is not suitable for irrigation and well water is not suitable for consumption or irrigation. Wastewater should be treated before discharge and the tailings area should be remediated in order to stop the pollution.
Źródło:
Journal of Water and Land Development; 2021, 48; 16-21
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The determination of microplastic contamination in freshwater environments using sampling methods : A case study
Autorzy:
Karaban, Kamil
Poniatowska, Agnieszka
Kaliszewicz, Anita
Winczek, Michał
Ilieva-Makulec, Krassimira
Romanowski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/27312655.pdf
Data publikacji:
2023
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
fraction of microfibres
mesoplastic
microplastic contamination
water pollution
Opis:
We compared different net sampling methods for microplastic quantitative collection by sampling different water volumes with nets of different mesh sizes. Sampling covered freshwater lake and reservoir with a significant degree of eutrophication located in Central Poland. The fibres were the main type of plastic collected from sampling sites and constituted 83% of all microplastic particles. Fibres of 700-1900 μm dominated in the samples. The size of mesh affected the amount of fibres collected. Small fibres of 10-200 μm in length were collected using only a fine net of 20 μm mesh size. The total amount of fibres depended on sample volumes; concentrations of microplastics were higher for smaller water volumes. It is likely that clogging with phytoplankton and suspended particles reduced the filtration capacity of the finest nets when large volumes were sampled, which led to an underestimation of microplastic. To our knowledge, this is the first study to provide evidence that the amount of small microfibres depends on mesh size and that the total microplastic abundance in freshwaters in Poland depends on the sample volume. We suggest sampling rather larger than smaller water volumes to assess the level of microplastic contamination more accurately, but clogging, which reduces the filtration capacity of finest nets, should be taken into account when eutrophic freshwater environments are studied.
Źródło:
Journal of Water and Land Development; 2023, 57; 140--146
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of pozzolan in trickling filter for secondary treatment of urban wastewater in Tlemcen, Algeria
Autorzy:
Hamidi, Amina
Belarbi, Fadila
Bouchelkia, Hamid
Bouchenak Khelladi, Racha M.
Powiązania:
https://bibliotekanauki.pl/articles/2174349.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
physicochemical parameters
pollution
pozzolan
trickling filter
wastewater treatment
Opis:
The research aims to study the purification performance of a local and natural material as an input or as a biological filter for treating urban domestic wastewater. For this purpose, pozzolan was used as the biofiltration support that was provided from Beni Saf located in the North-West of Algeria. Tests were carried out with a specially modified pilot unit (TE900) for wastewater treatment over a period of four months. To assess the efficiency of the treatment, two main parameters have been focused on - the height of the sprinkler filter (40 cm and 80 cm) and the flow rate (10, 16, and 25 dm3∙h-1). Physicochemical and bacteriological analyses were carried out on raw wastewater and treated water. The obtained results show that the Beni Saf pozzolan-filled trickling filter eliminates a large fraction of the studied pollutants. The purification yields obtained are fairly encouraging; 98% for turbidity, 88% for suspended solids (SS), 94% for chemical oxygen demand (COD), and 98% for biological oxygen demand (BOD5 ). As for bacterial indicators, the formation of biofilms has significantly reduced bacterial activity with a percentage of over 80%. It can be concluded that the reduction of pollutant parameters clearly indicates the effectiveness of the treatment by this ecological process. Therefore, the use of local and natural materials for wastewater treatment can be a promising alternative based on sustainable environmental technologies and development.
Źródło:
Journal of Water and Land Development; 2022, 55; 166--177
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor
Autorzy:
Kurek, Karolina
Bugajski, Piotr
Operacz, Agnieszka
Młyński, Dariusz
Wałęga, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/292901.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
pollution indicators
technological reliability
wastewater treatment plant
Weibull method
Opis:
The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in Lesser Poland, in Siepraw commune. The analysis was performed using the Weibull method for basic indicators of impurities, BOD5, CODCr and total suspended solids. Physico-chemical analyses of raw and treated wastewater, were carried out in the period from 2003 to 2014 (11 years). The research period included measured values of pollutions indicators in 38 samples of raw and treated sewage. For each of pollution indicators descriptive statistic, percentage reduction (n) and treatment plant reliability factors (RF) were calculated. Average reduction for BOD5 and TSS was on level equal 94%, only for COD the average reduction was lower and was on level 89%. The reliability values determined by Weibull method, were: 75% (BOD5), 90% (CODCr) and 89.5% (TSS). The reliability results have been lower than the presented by literature source, which means that work of wastewater treatment plant in Siepraw was not satisfied in 11 years of research.
Źródło:
Journal of Water and Land Development; 2020, 46; 146-152
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of characteristics, water quality and groundwater vulnerability in Pakis District, East Java Province, Indonesia
Autorzy:
Rubiantoro, Prasetyo
Bisri, Mohammad
Afandhi, Aminudin
Powiązania:
https://bibliotekanauki.pl/articles/2073736.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
geoelectrics
groundwater
intrinsic vulnerability
pollution
groundwater quality
specific vulnerability
Opis:
Groundwater is a very important natural resource to support the activities of the residents of Pakis District, Malang Regency. On the other hand, increased activity puts pressure on groundwater quality. Agricultural intensification, urbanisation, and industrialisation can be sources of pollutants. Hydrological factors, topography, lithology, and surrounding rainfall are triggers for contamination of groundwater. The main objective of this research is to determine the characteristics, quality of groundwater, and its susceptibility to pollution. To complete this research, geoelectric measurements were carried out at 43 points spread throughout the study area and sampling of 18 shallow wells in agricultural, residential, and industrial areas for chemical analysis. All data obtained were analysed to create a map of the spatial distribution of groundwater vulnerability. The results show that the groundwater in the study location is in the transition zone and flows through the volcanic rock layers. The level of groundwater pollution is in the uncontaminated status to heavily polluted with pollutants in the form of heavy metal manganese and Escherichia coli bacteria. The spatial distribution of groundwater intrinsic vulnerability shows low, moderate, and high levels of vulnerability, respectively 32.99%, 60.87%, and 6.14% of the research area. Groundwater specific vulnerability associated with land use factors shows that 26.25% are negligible, 42.46% are low, and 31.29% are moderate. From this it can be concluded that the study area has been polluted both geogenically and anthropogenically, therefore, special actions must be taken to restore the quality of groundwater.
Źródło:
Journal of Water and Land Development; 2022, 52; 124--132
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indirect estimation of black carbon concentration in traffic site based on other pollutants : time variability analysis
Autorzy:
Kamińska, Joanna A.
Kazak, Jan K.
Powiązania:
https://bibliotekanauki.pl/articles/27312613.pdf
Data publikacji:
2023
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
air pollution
black carbon
carbon monoxide
indirect estimation
traffic
Opis:
Aiming to create more sustainable cities it is necessary to understand and manage different ecological factors which influence human health. One of such factors is black carbon (BC) in atmosphere, which currently is not commonly monitored by environmental monitoring systems. The aim of this research was to estimate by indirect approach the relation between eBC (equivalent of black carbon) concentration and other air pollutants in order to define approximate level of eBC in more efficient approach. The study was conducted in Wrocław (Poland) in October 2021, and combined data on eBC concentration (measured by microaethalometer), air quality (from national environmental monitoring system) and traffic (from municipal traffic management system). Quantile regression was used to assess the relationship between the concentrations of pollutants. The obtained results show that for rise 1 mg∙m-3 of carbon monoxide, eBC concentration rise between 4.2 and 8.0 μg∙m-3, depending on the period of a day. Precision of eBC concentration evaluation is influenced by sun light which results in higher precision of defining a scaling factor for night hours. Outcomes of this study constitute an added value to understanding of interconnections between different factors describing environmental conditions in cities and might be helpful for more effective environmental assessment of human habitats.
Źródło:
Journal of Water and Land Development; 2023, 58; 1--10
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological pollution of soils and surface waters of the Pokuttia-Bukovyna Carpathians
Autorzy:
Masikevych, Andrij
Masikevych, Yurij
Malovanyу, Myroslav S.
Blyzniuk, Mykola
Powiązania:
https://bibliotekanauki.pl/articles/2174329.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bacteria
ecosystem
hydrosphere
microbiological pollution
national nature park
soil
Opis:
Based on the analysis of a number of studies, it was found that to assess the state of the environment (including surface waters and soils) it is advisable to use indicators of microbiological pollution, which in general integrally reflect the state of the ecosystem. To assess the dynamics of changes in the pollution of the studied areas, a comparison of monitoring data with the corresponding level of pollution in protected areas (Vyzhnytsia National Nature Park) was used. Research methods included soil and surface water sampling, inoculation on appropriate nutrient selective media, counting of colony forming units (CFU) and other microbiological indicators. To assess the biological activity of soils, urease activity was determined by a method generally accepted in biochemistry. It is established that within the protected areas, despite some existing annual fluctuations, the relative stability of the studied indicators of the hydrosphere is preserved. Studies have shown that soils of anthropogenically altered landscapes are characterised by a high content of sanitary-indicative bacteria. As our research shows, according to the colony forming units (CFU), total microbial count, and titer of Escherichia coli, the soils selected in the protected area of the Vyzhnytsia National Nature Park correspond to the “pure” level. The soils of the territories out of the National Nature Park are characterised by high biological capacity, as evidenced by the level of activity of the enzyme urease and the ratio of the main forms of nitrogen compounds.
Źródło:
Journal of Water and Land Development; 2022, 55; 91--96
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of groundwater vulnerability to pollution using the Kherici’s method in the Talezza plain, Collo region (NE Algeria)
Ocena podatności wód gruntowych na zanieczyszczenia przy użyciu metody Kherici w regionie Collo na równinie Talezza (NE Algieria)
Autorzy:
Attoui, B.
Benrabah, S. T.
Majour, H.
Zair, N.
Powiązania:
https://bibliotekanauki.pl/articles/946925.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
risk of pollution
self-purification
Talezza plain
unsaturated zone
vulnerability to pollution
podatność na zanieczyszczenia
równina Talezza
ryzyko zanieczyszczenia
samooczyszczanie
strefa nienasycona
Opis:
The intrinsic vulnerability of groundwater aquifers refers to their sensitivity to all contamination coming from soil surface irrespective of the nature of the polluting. In order to improve the protection of groundwater, there must be a reduction in the infiltration of contaminants towards the reservoir through the impacting factors determination of this phenomenon by means of research. There are collected models that include particular number of factors which allow the determination of a sign of groundwater vulnerability of all superficial pollutions. The goal of the study centers on ascertaining the state of vulnerability and the risk of groundwater pollution of the Collo region with a new proposed method by Kherici. Generally, assessment methods of vulnerability and the danger of groundwater pollution employ parametric systems with numerical quotation, cartographic superposition where the analytical methods are based on equations. In this study, we consider the combination of criteria dependent on natural factors (thickness of the unsaturated zone, geologic facies, degree of auto-purification) and the causes of groundwater vulnerability to man-made pollution (anthropogenic factors).
Podatność podziemnych poziomów wodonośnych odnosi się do ich wrażliwości na zanieczyszczenia pochodzące z powierzchni gleby, niezależnie od ich charakteru. Dla ochrony wód gruntowych konieczne jest ograniczenie infiltracji zanieczyszczeń po ustaleniu czynników wpływu metodami badawczymi. Istnieją modele obejmujące szereg czynników, które umożliwiają określenie podatności wód gruntowych na zanieczyszczenia powierzchniowe. Celem badań było określenie stanu podatności i ryzyka zanieczyszczenia wód gruntowych w regionie Collo za pomocą nowej metody zaproponowanej przez Kherici. W metodach oceny podatności i zagrożenia zanieczyszczeniem wód gruntowych stosowane są zwykle parametryczny system numeryczny i kartograficzne nałożenia, w których metody analityczne bazują na równaniach. W pracy rozważano kombinację kryteriów zależnych od czynników naturalnych (miąższość strefy nienasyconej, facje geologiczne i stopień samooczyszczenia) oraz przyczyny podatności wód gruntowych na zanieczyszczenia antropogeniczne.
Źródło:
Journal of Water and Land Development; 2017, 33; 23-30
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physicochemical characterization of synclinal spring water of Taoura, region of Souk Ahras – North East Algeria
Autorzy:
Bouhafs, Fatma
Laraba, Abdelaziz
Powiązania:
https://bibliotekanauki.pl/articles/1841971.pdf
Data publikacji:
2021
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
chemistry
principal component analysis
PCA
pollution
springs
Taoura
water quality
Opis:
The springs of the Taoura region flow from a syncline shaped structure. All resources in the region were mobilized as a result of increased demand. However, the development of anthropic activities and population growth in the area pose risk for groundwater. Analytical results obtained from a series of samplings in November 2017–April 2018, express the quality of water suitable for the irrigation of agricultural land. The highest values are recorded in April 2018 at 20.5 to 21.6°C and pH of 8.0 to 8.2. The study recorded high electrical conductivity from 1390 to 1495 μS∙cm–1 and TDS from 1270 to 1500 mg∙dm–3 in November 2017, which shows important mineralization that characterizes spring water. Physical parameters were measured in situ using a HORIBA multi-parameter probe. Chemical analyses were carried out using NFT 90-005 titration, and nitrogen parameters by DIN 38405-D92 spectrophotometry. Maximum levels of nitrates and phosphates were recorded at 228 and 18.4 mg∙dm–3 respectively. The principal component analysis (PCA) showed a good correlation of the November 2017 period with mineralization parameters. Moreover, there is a strong correlation between the wet period and pollution factors. The two methods of analysis has allowed to distinguish three groups of geochemical water types: a bicarbonate calcium group typical for waters having transited in carbonate horizons. A second chloride calcium group shows basic exchange between water and clay levels, and the third chloride bicarbonate calcium group reveals an enrichment in calcium and chloride, which reflects water circulation with an exchange of the carbonated and evaporitic sedimentary rock matrix.
Źródło:
Journal of Water and Land Development; 2021, 50; 27-37
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of phytoplankton communities for assessment of water quality in the Wadaslintang Reservoir in Indonesia
Autorzy:
Piranti, Agatha S.
Wibowo, Dwi N.
Powiązania:
https://bibliotekanauki.pl/articles/946893.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
algae
pollution level
Shannon-Wiener index
Storet index
water quality
Opis:
The use of phytoplankton as an indicator of water pollution is a promising tool for assessment of water quality. The purpose of this study was to determine whether diversity indices, including the species richness and diversity of phyto-plankton, could be used for reliable assessment of water quality in the Wadaslintang Reservoir in Indonesia. Surveys were conducted monthly at eight sites, from July 2019 to October 2019. Phytoplankton was collected during the day at 10:00 until approximately 15:00 in the euphotic zone. The parameters investigated were species richness and the abundance of phytoplankton, as well as water quality parameters listed in Government Regulation Number 82 of 2001. The level of pollution was represented biologically by the Shannon–Wiener diversity index and physicochemically by the STORET (storage and retrieval of water quality data) index. Moreover, the two indices were compared to determine whether a particular diversity index was more effective for assessment of this reservoir. The results showed that during the dry season, 22 taxa of phytoplankton were present, belonging to Cyanophyta, Chlorophyta, Chrysophyta, and Euglenophyta. During the wet season, 29 taxa were found, belonging to Cyanophyta, Chlorophyta, and Chrysophyta. Based on the Shannon-Wiener index and STORET index, water quality was better during the wet season than during the dry season. The results of water quality assessment using both indices were consistent, but the diversity index was a more sensitive indicator of pollution levels. Therefore, the Shannon–Wiener index is a useful tool for assessment of water quality in the Wadaslintang Reservoir.
Źródło:
Journal of Water and Land Development; 2020, 46; 170-178
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physical-chemical characterisation of the urban wastewater - case study of the Boumerdes region, North - Algeria
Autorzy:
Ait Baziz, Djalal
Maazouzi, Abdelhak
Lachache, Salih
Powiązania:
https://bibliotekanauki.pl/articles/2174372.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
Boumerdes
physical-chemical parameters
pollution
urban wastewater
water quality standards
Opis:
The objective of this study is to assess the physical-chemical quality of urban wastewater from the city of Boumerdès, in northern Algeria with regard to the threshold values for irrigation or their discharge in aquatic ecosystems. Five sampling points were carried out of the study area in April 2017. The results obtained of physical-chemical parameters indicating pollution show that the water course is exposed to pollution mainly of organic origin. It’s expressed by a high maximum value according to Algerian and World Health Organisation standards: chemical oxygen demand (COD 886 mg O2∙dm-3), biochemical oxygen demand (BOD5 490 mg O2∙dm-3), nitrate (NO3- 73.09 mg∙dm-3), nitrite (NO2- 6 mg∙dm-3), ammonium (NH4+ 23 mg∙dm-3) and phosphates (PO43- 7.3 mg∙dm-3). The COD to BOD5 rate of 1.8, show that the effluents must be treated before being discharged into the receiving environment. However, it is lower than 2, which makes them easily biodegradable and can be treated by a biological system such as a natural lagoon. It shows also a diversified origin of the pollution. It is predominantly domestic origin, it could have an adverse effect on public health, presenting a risk of environmental eutrophication, contamination of soil and water resources. The physical-chemical characterisation of the urban wastewater shows that they are quite loaded and prezent a pollution in nitrogenous compounds, a treatment is requested before the direct discharge to the receiving environment or their reuse in the irrigation.
Źródło:
Journal of Water and Land Development; 2022, 54; 243--250
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The minimization of impact of oil pollution on soils in the area of railways using glauconite
Autorzy:
Chayka, Oksana
Petrushka, Igor
Ruda, Maria
Paranyak, Nadiya
Matskiv, Olena
Powiązania:
https://bibliotekanauki.pl/articles/1844318.pdf
Data publikacji:
2021
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ecological safety
glauconite
oil products
pollution
railway transport
soil contamination
Opis:
The analysis of ecological hazards on soil pollution by oil products has been provided in the impact zone of the railway. The results of oil product migration in soils in the area of influence on section Lviv–Khodoriv are given. To study this problem, a method was used to take soil samples according to the standard DSTU ISO 10381-4: 2005. To determine the content of petroleum products used the method MVV No. 081/12-0116-03 Pochvy. Based on the results of the study it was found that contamination with petroleum products in the study area exceeds the norm in the area of influence of the railway at a distance of 5 to –50 m on average 3.5 times. It is proposed to make management decisions to prevent violations of the sanitary protection zone of the railway and the placement of agricultural plots on it. For rehabilitation of contaminated soils, it is advisable to use a natural sorbent – glauconite, which is widespread in the bowels of Ukraine. The adsorption capacity of glauconite relative to diesel fuel has been experimentally established. According to our experiments it is proved the high efficiency of the proposed sorbent, which is 90%. Therefore, in the future it is necessary to periodically monitor the condition of the soil in the area to prevent pollution. This study proves that this practice is necessary.
Źródło:
Journal of Water and Land Development; 2021, 49; 79-84
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of trace elements pollution in snow piles removed from residential areas in Perm, Russia
Autorzy:
Ushakova, Evgeniya
Menshikova, Elena
Karavaeva, Tatiana
Puzik, Alexey
Volkova, Margarita
Vaganov, Sergey
Powiązania:
https://bibliotekanauki.pl/articles/2203544.pdf
Data publikacji:
2023
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
contamination level
de-icing agents
phytotoxicity
pollution sources
snow quality
Opis:
Atmospheric deposition, vehicular transportation and de-icing agents are major sources polluted snow in urban. This study investigates the current trace elements concentrations of snow and de-icing using ICP-MS, and phytotoxicity using three vascular plants in snow. The study assesses the contamination, classification and phytotoxicity of snow quality removed from roads of residential areas and piled on children’s playgrounds in residential territories. The research found that according to Russian environmental quality standard for water has been identified the exceeding trace elements in snow by W, Se, Mn, Cu, V, Mo, Ni and Zn. The pollution indices (PLI, CF and Zc) were identified pollution level of snow piles from moderate contamination to very high contamination. Based on average germination index values for Sinapis alba L., Lepidium sativum L., and Triticum aestivum L., the degree of inhibition in snow piles varied from no inhibition to strong inhibition. The trace elements content in de-icing “Galit А” and salt sand mix are defined in the following descending order: Zn > Mn > Ba > V > Rb > Sr and Mn > Ba > Cr > V > Sr > Ni, respectively. High concentrations of trace elements in snow piles are a source of environmental pollution. To prevent snow storage and disposal in residential areas should be involved in future studies of environmental pollution and circular economy, so that environmental managers can reduce threats to the environment and public health, as well as initiate circular economy projects in urban areas.
Źródło:
Journal of Water and Land Development; 2023, 56; 109--117
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies