Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sobczak, Marek." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
The role of ultrasound and lymphoscintigraphy in the assessment of axillary lymph nodes in patients with breast cancer
Rola badania ultrasonograficznego oraz limfoscyntygrafii w diagnostyce węzłów chłonnych pachowych u pacjentek z rakiem piersi
Autorzy:
Nieciecki, Michał
Dobruch-Sobczak, Katarzyna
Wareluk, Paweł
Gumińska, Anna
Białek, Ewa
Cacko, Marek
Królicki, Leszek
Powiązania:
https://bibliotekanauki.pl/articles/1052669.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
axillary lymph nodes
breast cancer
limfoscyntygrafia
lymphoscintigraphy
sentinel lymph node
ultrasound
rak piersi
ultrasonografia
węzeł wartowniczy
węzły chłonne pachowe
Opis:
Breast cancer is the most common malignancy and the leading cause of death due to cancer in European women. Mammography screening programs aimed to increase the detection of early cancer stages were implemented in numerous European countries. Recent data show a decrease in mortality due to breast cancer in many countries, particularly among young women. At the same time, the number of sentinel node biopsy procedures and breast-conserving surgeries has increased. Intraoperative sentinel lymph node biopsy preceded by lymphoscintigraphy is used in breast cancer patients with no clinical signs of lymph node metastasis. Due to the limited sensitivity and specificity of physical examination in detecting metastatic lesions, developing an appropriate diagnostic algorithm for the preoperative assessment of axillary lymph nodes seems to be a challenge. The importance of ultrasound in patient qualification for sentinel lymph-node biopsy has been discussed in a number of works. Furthermore, different lymphoscintigraphy protocols have been compared in the literature. The usefulness of novel radiopharmaceuticals as well as the methods of image acquisition in sentinel lymph node diagnostics have also been assessed. The aim of this article is to present, basing on current guidelines, literature data as well as our own experience, the diagnostic possibilities of axillary lymph node ultrasound in patient qualification for an appropriate treatment as well as the role of lymphoscintigraphy in sentinel lymph node biopsy.
Rak piersi jest najczęściej występującym nowotworem złośliwym i jednocześnie najczęstszą przyczyną zgonów z powodu chorób nowotworowych u kobiet w Europie. W kilkunastu krajach europejskich wprowadzano programy przesiewowych badań mammograficznych, mające przyczynić się do zwiększenia wykrywalności zmian nowotworowych o małym stopniu zaawansowania. Ostatnie dane wskazują, że w wielu z tych państw występuje spadek śmiertelności z powodu raka piersi, szczególnie w grupie kobiet młodych. Zwiększeniu ulega natomiast liczba procedur biopsji węzła wartowniczego i operacji oszczędzających. Śródoperacyjne pobranie węzła wartowniczego, poprzedzone badaniem limfoscyntygraficznym, stosuje się u chorych na raka piersi bez klinicznych cech przerzutów w węzłach chłonnych. Ze względu na ograniczoną czułość i swoistość badania fizykalnego w wykrywaniu tego typu zmian wyzwaniem wydaje się opracowanie właściwego algorytmu diagnostycznego w przedoperacyjnej ocenie węzłów chłonnych pachowych. Tematem szeregu prac jest znaczenie badania ultrasonograficznego w kwalifikacji pacjentek do biopsji węzła wartowniczego. W piśmiennictwie porównywane są także różne protokoły limfoscyntygrafii. Ocenie podlega też przydatność nowych radiofarmaceutyków oraz metod akwizycji obrazu w diagnostyce wartowniczych węzłów chłonnych. Celem artykułu jest przedstawienie – na podstawie aktualnych wytycznych, danych z piśmiennictwa oraz doświadczeń własnych autorów – możliwości diagnostycznych badania ultrasonograficznego węzłów chłonnych pachowych w kwalifikacji chorych do odpowiedniego leczenia oraz roli limfoscyntygrafii w procedurze biopsji węzła wartowniczego.
Źródło:
Journal of Ultrasonography; 2016, 16, 64; 5-15
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shear wave elastography in medullary thyroid carcinoma diagnostics
Zastosowanie elastografii fali poprzecznej w diagnostyce raka rdzeniastego tarczycy
Autorzy:
Dobruch-Sobczak, Katarzyna
Gumińska, Anna
Bakuła-Zalewska, Elwira
Mlosek, Krzysztof
Słapa, Rafał Z.
Wareluk, Paweł
Krauze, Agnieszka
Ziemiecka, Agnieszka
Migda, Bartosz
Jakubowski, Wiesław
Dedecjus, Marek
Powiązania:
https://bibliotekanauki.pl/articles/1052907.pdf
Data publikacji:
2015
Wydawca:
Medical Communications
Tematy:
badanie usg
rak rdzeniasty
sonoelastografia fali poprzecznej
tarczyca
shear wave elastography
Opis:
Shear wave elastography (SWE) is a modern method for the assessment of tissue stiffness. There has been a growing interest in the use of this technique for characterizing thyroid focal lesions, including preoperative diagnostics. Aim: The aim of the study was to assess the clinical usefulness of SWE in medullary thyroid carcinoma (MTC) diagnostics. Materials and methods: A total of 169 focal lesions were identified in the study group (139 patients), including 6 MTCs in 4 patients (mean age: 45 years). B-mode ultrasound and SWE were performed using Aixplorer (SuperSonic, Aix-en-Provence), with a 4–15 MHz linear probe. The ultrasound was performed to assess the echogenicity and echostructure of the lesions, their margin, the halo sign, the height/width ratio (H/W ratio), the presence of calcifications and the vascularization pattern. This was followed by an analysis of maximum and mean Young’s (E) modulus values for MTC (EmaxLR, EmeanLR) and the surrounding thyroid tissues (EmaxSR, EmeanSR), as well as mean E-values (EmeanLRz) for 2 mm region of interest in the stiffest zone of the lesion. The lesions were subject to pathological and/or cytological evaluation. Results: The B-mode assessment showed that all MTCs were hypoechogenic, with no halo sign, and they contained micro- and/ or macrocalcifications. Ill-defined lesion margin were found in 4 out of 6 cancers; 4 out of 6 cancers had a H/W ratio > 1. Heterogeneous echostructure and type III vascularity were found in 5 out of 6 lesions. In the SWE, the mean value of EmaxLR for all of the MTCs was 89.5 kPa and (the mean value of EmaxSR for all surrounding tissues was) 39.7 kPa Mean values of EmeanLR and EmeanSR were 34.7 kPa and 24.4 kPa, respectively. The mean value of EmeanLRz was 49.2 kPa. Conclusions: SWE showed MTCs as stiffer lesions compared to the surrounding tissues. The lesions were qualified for fine needle aspiration biopsy based on B-mode assessment. However, the diagnostic algorithm for MTC is based on the measurement of serum calcitonin levels, B-mode ultrasound and FNAB.
Elastografia fali poprzecznej jest nowoczesną metodą oceny sztywności tkanek. Obserwuje się wzrost zainteresowania tą techniką w różnicowaniu charakteru zmian ogniskowych w tarczycy również w diagnostyce przedoperacyjnej. Cel pracy: Celem niniejszej pracy była ocena klinicznej przydatności elastografii fali poprzecznej w diagnostyce raka rdzeniastego tarczycy (RRT). Materiał i metoda: W badanej grupie 139 pacjentów stwierdzono 169 zmian ogniskowych, a u 4 pacjentów (średni wiek: 45 lat) rozpoznano 6 RRT. Wykonano USG B-mode oraz elastografię fali poprzecznej aparatem Aixplorer (Super- Sonic, Aix-en-Provence), głowicą liniową o częstotliwości 4–15 MHz. W USG oceniano echogeniczność i echostrukturę zmian, ich brzegi, objaw „halo”, stosunek wysokości do głębokości (W/G), obecność zwapnień oraz wzorzec unaczynienia. Następnie analizowano: maksymalne i średnie wartości modułu Younga (E) dla największego ROI dla RRT (EmaxLR, EmeanLR) oraz dla otaczających tkanek w miąższu gruczołu (EmaxSR, EmeanSR), a także średnie wartości E (EmeanLRz) dla 2 mm obszaru zainteresowania z najsztywniejszej części zmiany. Zmiany zweryfikowano histopatologicznie i/lub cytologicznie. Wyniki: W ocenie B-mode wszystkie RRT były hipoechogeniczne, bez obecności objawu „halo”, oraz zawierały mikro- i/lub makrozwapnienia. Nieostre granice zmiany obecne były w 4 z 6 raków. Wartość ilorazu W/G > 1 dotyczyła 4 na 6 zmian. Niejednorodną echostrukturę oraz typ III unaczynienia stwierdzono w 5 na 6 zmian. W SWE średnia wartość EmaxLR w obrębie RRT wynosiła 89,5 kPa, w otoczeniu – 39,7 kPa. Średnie wartości EmeanLR, EmeanSR wynosiły odpowiednio: 34,6 kPa i 24,4 kPa. Wartość średnia EmeanLRz = 49,2 kPa. Wnioski: W SWE RRT przedstawiały się jako zmiany sztywniejsze w porównaniu z otaczającymi tkankami. W ocenie B-mode spełniały wskazania do biopsji aspiracyjnej cienkoigłowej. Jednak algorytm diagnostyczny RRT opiera się na pomiarze stężenia kalcytoniny w surowicy krwi, ocenie USG B-mode oraz biopsji.
Źródło:
Journal of Ultrasonography; 2015, 15, 63; 358-367
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies