Tytuł:
Children’s residential exposure to selected allergens and microbial indicators: endotoxins and (1→3)-β-D-glucans
Autorzy:
Kozajda, Anna
Bródka, Karolina
Sowiak, Małgorzata
Sobala, Wojciech
Polańska, Kinga
Jurewicz, Joanna
Hanke, Wojciech
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2179063.pdf
Data publikacji:
2013-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
children exposure
residential exposure
allergens
settled dust
endotoxins
glucans
Opis:
Objectives: The study was aimed at assessment of exposure to endotoxins, (1→3)-β-D-glucans and mite, cockroach, cat, dog allergens present in settled dust in premises of children as agents which may be significantly correlated with the occurrence of allergic symptoms and diseases in children. Materials and Methods: The study covered 50 homes of one- or two-year-old children in Poland. Samples of settled dust were taken from the floor and the child's bed. The levels of (1→3)-β-D-glucans (floor), endotoxins (floor) and allergens of mite, cat, dog and cockroach (floor and bed) were analyzed. Results: Average geometric concentrations (geometric standard deviation) of endotoxins, (1→3)-β-D-glucans, Der p1, Fel d1, Can f1 and Bla g1 in children homes were on the floor 42 166.0 EU/g (3.2), 20 478.4 ng/g (2.38), 93.9 ng/g (6.58), 119.8 ng/g (13.0), 288.9 ng/g (3.4), 0.72 U/g (4.4) and in their beds (only allergens) 597.8 ng/g (14.2), 54.1 ng/g (4.4), 158.6 ng/g (3.1) 0.6 U/g (2.9), respectively. When the floor was covered with the carpet, higher concentrations of endotoxins, (1→3)-β-D-glucans and allergens (each type) were found in the settled dust (p < 0.05). The trend was opposite in case of allergens (except dog) analyzed from bed dust and significantly higher concentrations were found in the rooms with smooth floor (p < 0.05). Conclusions: Among the analyzed factors only the type of floor significantly modified both the level of biological indicators and allergens. The results of this study could be the base for verifying a hypothesis that carpeting may have a protective role against high levels of cockroach, dog and cat allergens.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 6; 870-889
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor allergens in settled dust from kindergartens in city of Łódź, Poland
Autorzy:
Cyprowski, Marcin
Buczyńska, Alina
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2179064.pdf
Data publikacji:
2013-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
indoor allergens
settled dust
environmental exposure
allergen transportation
kindergartens
children
Opis:
Objectives: The main objective of the study was to determine the levels of house dust mite (Der p1), dog (Can f1), cat (Fel d1) and cockroach (Bla g2) allergens in kindergartens localized in an urban agglomeration. Material and Methods: A quantitative analysis of allergens was carried out in settled dust samples collected by vacuuming the floor surface in three kindergartens (N = 84) and children's clothing (N = 36). The samples were collected in springsummer and autumn-winter periods as well as at the beginning and end of the week. The allergen dust concentration was determined by enzyme-linked immunoenzymatic assay (ELISA). Results: The mean geometric concentrations (±geometric standard deviations) of allergens Der p1, Can f1, Fel d1 and Bla g2 determined in kindergartens were: 0.02±3.21 μg/g of dust; 0.97±4.49 μg/g of dust; 0.30±4.43 μg/g of dust and 0.01±3.08 μg/g of dust, respectively. Younger classrooms (children aged from 3 to 4 years) were characterized by almost twice higher mean concentration of allergen Fel d1, as compared to older classrooms (children aged from 5 to 6 years) (p < 0.05). A significant impact of seasonality on the level of dog allergen Can f1 was found (p < 0.05). No significant weekly variation was found in average concentrations of the allergens. Children who had a dog and/or cat at home were characterized by high concentrations of allergens Can f1 and Fel d1 on their clothes (59.2±5.39 μg Can f1/g of dust; 3.63±1.47 μg Fel d1/g of dust), significantly higher than concentrations of allergens in children who did not have any pets (p < 0.001). Conclusions: Special attention should be paid to keeping the kindergarten rooms tidy and clean and to an appropriate choice of furnishings and fittings which would prevent the proliferation of the house dust mite and accumulation of allergens.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 6; 890-899
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Endotoxin exposure and changes in short-term pulmonary function among sewage workers
Autorzy:
Cyprowski, Marcin
Sobala, Wojciech
Buczyńska, Alina
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2177186.pdf
Data publikacji:
2015-06-25
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
sewage workers
endotoxin exposure
inhalable dust
smoking
lung function
regression analysis
Opis:
Objectives The inhaled endotoxin is considered as a causative factor in the process of acute bronchial obstruction, which can be measured by a decrease in forced expiratory volume in 1 s (FEV₁). The aim of this study was to assess endotoxin exposure among sewage treatment plant workers (STPW) and its effect on across-shift changes in respiratory airflow. Material and Methods A group of 78 STPW from a large sewage treatment plant was studied. Inhalable dust for endotoxin assessment was collected using personal aerosol samplers. Endotoxin was assayed with the kinetic, chromogenic Limulus amebocyte lysate test. Across-shift spirometric measurements were performed on Mondays, after 2-days absence from work, with the use of portable spirometer. The forced vital capacity (FVC), and FEV₁ parameters were analyzed. Multifactor regression modeling was performed to determine parameters significantly associated with endotoxin exposure. Results The concentration of inhalable dust and endotoxin ranged from 0.01–1.38 mg/m³ and 0.68–214 endotoxin units per cubic meter of air (EU/m³), respectively. Endotoxins were characterized with the skewed distribution (arithmetic mean (AM) = 38.8 EU/m³, geometric mean (GM) = 15.4 EU/m³, geometric standard deviation (GSD) = 4.21). Through the use of multifactor analysis, which excluded the main confounders (inhalable dust and smoking habit) it was found that, despite low levels of endotoxin, it had significant impact on the observed across-shift decline in FEV₁ (p = 0.044). For this parameter, the regression slope was additionally calculated (r = –0.017, p = 0.071). Conclusions Relatively low levels of endotoxin among sewage treatment plant workers may cause small, but significant across-shift declines in FEV₁. The observed relationship was independent of organic dust concentrations and smoking habit. The respiratory protection should be provided for STPW.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 5; 803-811
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The respiratory effects of toner exposure according to long-term occupational toner handling history: A longitudinal analysis, 2004–2013
Autorzy:
Hasegawa, Masayuki
Kitamura, Hiroko
Ikegami, Kazunori
Masuda, Masashi
Kakiuchi, Noriaki
Matsushita, Tetsuhiro
Kuga, Hiroaki
Uchiyama, Tetsuro
Kurogi, Kazushiro
Mizuno, Mitsuhito
Ogami, Akira
Higashi, Toshiaki
Powiązania:
https://bibliotekanauki.pl/articles/2162039.pdf
Data publikacji:
2018-12-20
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
respiratory disease
printer
toner dust
longitudinal analyses
respiratory effects
occupational exposure
Opis:
Objectives This report shows the relationship between toner exposure and respiratory effects for individuals with a longterm occupational toner-handling history, from 2004 to 2013. Material and Methods Authors studied 752 Japanese male workers in toner handling workshops. A total of 673 men who participated in an annual monitoring survey were analyzed in this study. The following monitoring was performed in the same season each year: personal exposure measurements, biological markers, respiratory function tests, a chest X-ray, chronic respiratory symptoms and incidences of respiratory diseases. To evaluate the toner exposure effect, the exposure categories suitable for each evaluation index were established. Results For those with an occupational toner-handling history, the mean occupational toner-handling period was 14.36 years (standard deviation = 6.62); one participant had 35 years of exposure, which was the longest and one participant had 1 year of exposure which was the shortest. There were no statistically significant differences in the rate of change of respiratory function tests. An ANOVA conducted on blood and urine test results showed that statistically significantly differences were observed for a few items but all the values were very low and within the standard range. Conclusions Authors conducted a 10-year ongoing study, but no obvious negative influences on health were attributed to toner exposure. In a work environment where adequate administrative controls are in place, personal toner exposure levels may be expected to be low, with no adverse effects on human health. Int J Occup Med Environ Health 2018;31(6):809–822
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 6; 809-822
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A quantitative risk assessment of sinonasal cancer as a function of time in workers occupationally exposed to wood dust
Autorzy:
Soćko, Renata
Powiązania:
https://bibliotekanauki.pl/articles/2086482.pdf
Data publikacji:
2021-08-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
risk assessment
wood dust
mathematical models
carcinogenicity
nasal cancer
Opis:
ObjectivesThe aim of this study is to conduct a quantitative assessment of the risk related to occupational exposure to wood dust and the occurrence of sinonasal epithelial cancer (SNEC) by histotype, depending on the duration of exposure, using mathematical models.Material and MethodsThe relationship between the occurrence of SNEC by histotype (adenocarcinoma [AR] and tumors of other histotypes) and exposure to wood dust has been studied using the values of the odds ratios for individual periods of employment involving exposure to wood dust, and their 95% confidence intervals. The dose-response curves were constructed (more precisely, the duration of exposure-response curves). The author attempted to match the linear, quadratic or exponential models.ResultsIn all SNEC cases, there is a relationship between the duration of occupational exposure to wood dust and the relative risk of developing cancer. The estimated relative risk of developing AR after 35 years of exposure to wood dust is about 300, and the estimated risk of developing SNEC is 50, compared to non-exposed people for whom the relative risk is equal to 1. However, the relative risk of developing other types of cancer is <20, also in comparison with non-exposed people.ConclusionsThe author has identified a relationship between the duration of occupational exposure to wood dust and the relative risk of developing cancer in all SNEC cases.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2021, 34, 4; 541-549
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to culturable and total microbiota in cultural heritage conservation laboratories
Autorzy:
Górny, Rafał L.
Harkawy, Aleksander S.
Ławniczek-Wałczyk, Anna
Karbowska-Berent, Joanna
Wlazło, Agnieszka
Niesler, Anna
Gołofit-Szymczak, Małgorzata
Cyprowski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2177074.pdf
Data publikacji:
2015-10-23
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
settled dust
bioaerosol
conservation laboratory
cultural heritage
occupational exposure
microbial hazards
Opis:
Objectives To date, the scientific source materials usually focus on microbial contamination of the museum or library collections themselves, while the exposure of persons who professionally deal with this type of objects in cultural heritage conservation laboratories is ignored. Material and Methods The study was carried out in 9 naturally ventilated conservation laboratories with no history of water damage. Viable (understood as culturable) bioaerosol stationary samples were collected in both outdoor and indoor environments using 6-stage Andersen impactor. Simultaneously, stationary and personal indoor bioaerosol measurements were carried out using both Gesamtstaubprobenahme an der Person (GSP) and Button filter samplers. These measurements were complemented by evaluation of microbial content in the dust settled on conserved works of art. All impactor, filter, and settled dust samples were quantitatively examined to obtain viable and total concentrations of bacteria and fungi. All isolated microbial strains were taxonomically identified. Results At workplaces, the concentrations of viable microorganisms in air were below 2000 cfu/m³ and accounted for not more than 5.5% of total microbiota. The study showed that quantitative assessment of viable bioaerosol can be made with an Andersen impactor as well as by using Button and GSP filter samplers, irrespective of whether they are applied for personal or stationary measurements. Compared to the impactor, however, the use of filter samplers for microbial contamination monitoring substantially limits the scope of qualitative information which can be obtained. Size distribution analysis revealed that the largest “load” of microorganisms can penetrate into the respiratory tract between the trachea and terminal bronchi, and thereby may be responsible for allergic inflammations in exposed workers. Conclusions The precise assessment of microbial hazards in conservation laboratories should comprise control of both viable and total particle counts. The hermetization of such workplaces and control of relative humidity should be implemented and maintained to assure proper hygienic conditions.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 2; 255-275
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies