Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "airborne fungi" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Occurrence of fungi and cytotoxicity of the species: Aspergillus ochraceus, Aspergillus niger and Aspergillus flavus isolated from the air of hospital wards
Autorzy:
Gniadek, Agnieszka
Krzyściak, Paweł
Twarużek, Magdalena
Macura, Anna B.
Powiązania:
https://bibliotekanauki.pl/articles/2161861.pdf
Data publikacji:
2017-03-30
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
cytotoxicity
airborne fungi
MTT assay
Aspergillus
air sampling
hospital environment
Opis:
Objectives The basic care requirement for patients with weakened immune systems is to create the environment where the risk of mycosis is reduced to a minimum. Material and Methods Between 2007 and 2013 air samples were collected from various wards of a number of hospitals in Kraków, Poland, by means of the collision method using MAS-100 Iso MH Microbial Air Sampler (Merck Millipore, Germany). The air mycobiota contained several species of fungi, and almost 1/3 of it was made up of the species of the Aspergillus genus. Sixty-one strains of species other than A. fumigatus were selected for the research purposes, namely: 28 strains of A. ochraceus, 22 strains of A. niger and 11 strains of A. flavus species. Selected fungi underwent a cytotoxicity evaluation with the application of the MTT colorimetric assay (3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide). The assay assesses cell viability by means of reducing the yellow tetrazolium salt to insoluble formazan. A semi-quantitative scale for cytotoxicity grading was adopted: low cytotoxic effect (+) with half maximal inhibitory concentration (IC₅₀) for values ranging from 31.251 cm²/ml to 7.813 cm²/ml, medium cytotoxic effect (++) for values ranging from 3.906 cm²/ml to 0.977 cm²/ml and the high one (+++) for values ranging from 0.488 cm²/ml to 0.061 cm²/ml. The absence of cytotoxicity was determined when the IC₅₀ values was at ≥ 50. Results For 48 samples the analyzed fungi displayed the cytotoxic effect with A. ochraceus in 26 out of 28 cases, with 11 strains displaying the high cytotoxic effect. The lowest cytotoxicity was displayed by fungi of A. niger in 13 out of 22 cases, and the major fungi of A. flavus species were toxic (9 out of 11 cases). Conclusions A half of the fungi displayed the low cytotoxic effect. On the basis of the comparison of average cytotoxicity levels it was determined that there were significant differences in the levels of cytotoxicity of the analyzed fungi. However, such statement may not provide grounds for a definite conclusion about the compared species of fungi that display a more cytotoxic effect than others. Int J Occup Med Environ Health 2017;30(2):231–239
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 2; 231-239
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Visible fungi growth and dampness assessed using a questionnaire versus airborne fungi, (1→3)-β-d-glucan and fungal spore concentrations in flats
Autorzy:
Sowiak, Małgorzata
Jeżak, Karolina
Kozajda, Anna
Sobala, Wojciech
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2177035.pdf
Data publikacji:
2015-02-24
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
glucans
fungal spores
airborne fungi
questionnaire survey
dwelling contamination
residential exposure
Opis:
Introduction: The study aimed at determination of the usefulness of the subjective assessment of selected signs of fungi growth in flats and microclimate parameters to indicate the actual air contamination with culturable fungi, (1→3)-β-D-glucans and fungal spores. Material and methods: This analysis covered 22 flats, the inhabitants of which declared in a questionnaire interview the presence of the developed mycelium on solid surfaces in the flat. Air samples for determination of the culturable fungi, (1→3)-β-D-glucans and (viable and non-viable) fungal spores concentrations indoor and outdoor the flats during the heating period were collected. During bioaerosol sampling microclimate parameters were measured. Predictive models for concentrations of the tested biological agents with regard to various ways to assess fungal contamination of air in a flat (on the basis of a questionnaire or a questionnaire and microclimate measurements) were built. Results: The arithmetic means of temperature, relative humidity, CO₂ concentration and air flow velocity in the flats were respectively: 20.5°C, 53%, 1431.6 ppm and 0 m/s. The geometric mean concentrations of airborne fungi, (1→3)-β-D-glucans and fungal spores in these premises amounted to 2.9×10² cfu/m³, 1.6 ng/m³ and 5.7×10³ spores/m³, respectively. The subjective assessment of fungi growth signs and microclimate characteristics were moderately useful for evaluation of the actual airborne fungi and (1→3)-β-D-glucan concentrations (maximum percent of explained variance (VE) = 61% and 67%, respectively), and less useful in evaluation of the actual fungal spore concentrations (VE < 29%). In the case of fungi, higher usefulness was indicated of the questionnaire evaluation supported by microclimate measurements (VE = 61.2%), as compared to the evaluation only by means of a questionnaire (VE = 46.9%). Conclusions: Subjective evaluation of fungi growth signs in flats, separately or combined with microclimate measurements, appeared to be moderately useful for quantitative evaluation of the actual air contamination with fungi and their derivatives, but more extensive studies are needed to strengthen those findings.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 1; 130-146
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of sampling airborne fungi in working environments of waste treatment facilities
Autorzy:
Černá, Kristýna
Wittlingerová, Zdeňka
Zimová, Magdaléna
Janovský, Zdeněk
Powiązania:
https://bibliotekanauki.pl/articles/2177446.pdf
Data publikacji:
2015-12-30
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
airborne fungi
waste sorting facility
filter based bioaerosol sampling
surface air system method
working environment
plastics
Opis:
Objectives The objective of the present study was to evaluate and compare the efficiency of a filter based sampling method and a high volume sampling method for sampling airborne culturable fungi present in waste sorting facilities. Material and Methods Membrane filters method was compared with surface air system method. The selected sampling methods were modified and tested in 2 plastic waste sorting facilities. Results The total number of colony-forming units (CFU)/m³ of airborne fungi was dependent on the type of sampling device, on the time of sampling, which was carried out every hour from the beginning of the work shift, and on the type of cultivation medium (p < 0.001). Detected concentrations of airborne fungi ranged 2×10²–1.7×10⁶ CFU/m³ when using the membrane filters (MF) method, and 3×10²–6.4×10⁴ CFU/m³ when using the surface air system (SAS) method. Conclusions Both methods showed comparable sensitivity to the fluctuations of the concentrations of airborne fungi during the work shifts. The SAS method is adequate for a fast indicative determination of concentration of airborne fungi. The MF method is suitable for thorough assessment of working environment contamination by airborne fungi. Therefore we recommend the MF method for the implementation of a uniform standard methodology of airborne fungi sampling in working environments of waste treatment facilities.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 3; 493-502
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies