Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ewa, Cieślik," wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Cardiotoxic effect due to accidental ingestion of an organic solvent
Autorzy:
Cieślik-Guerra, Urszula I.
Rechciński, Tomasz
Trzos, Ewa
Wierzbowska-Drabik, Karina
Uznańska-Loch, Barbara
Winnicka, Renata
Krakowiak, Anna
Kasprzak, Jarosław D.
Fröhlich, Colin
Kurpesa, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2177006.pdf
Data publikacji:
2015-02-24
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
miocardial infarction
cardiotoxicity
xylene
poisoning
volatile organic compounds
toluene
Opis:
Toxic myocardial injury can be misdiagnosed as a myocardial infarction, resulting in the patient undergoing standard treatment for cardiac rehabilitation. However, such inadequate therapeutic strategies can lead to cardiovascular complications including dilated cardiomyopathy. This study presents a case of a 65-year-old man after accidental ingestion of organic solvents (toluene and xylene), whose condition demonstrated all the criteria for diagnosis of myocardial infarction. The qualitative determinations of the above mentioned volatile organic compounds (VOCs) in whole blood were carried out using a headspace sampling by means of gas chromatography. Cardiac catheterization revealed no specific coronary lesions, only a muscular bridge causing a 30–50% stenosis in the middle of the circumflex branch of the left coronary artery.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 1; 174-179
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification and characteristics of biological agents in work environment of medical emergency services in selected ambulances
Autorzy:
Bielawska-Drózd, Agata
Cieślik, Piotr
Wlizło-Skowronek, Bożena
Winnicka, Izabela
Kubiak, Leszek
Jaroszuk-Ściseł, Jolanta
Depczyńska, Daria
Bohacz, Justyna
Korniłłowicz-Kowalska, Teresa
Skopińska-Różewska, Ewa
Kocik, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/2161907.pdf
Data publikacji:
2017-06-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
bacteria
fungi
work environment
harmful biological agents
antimicrobial resistance
ambulances
Opis:
Objectives Assessment of microbial air quality and surface contamination in ambulances and administration offices as a control place without occupational exposure to biological agents; based on quantitative and qualitative analysis of bacteria, yeasts and filamentous fungi found in collected samples. Material and Methods The sampling was done by wet cyclone technology using the Coriolis recon apparatus, imprint and swab methods, respectively. In total, 280 samples from 28 ambulances and 10 offices in Warszawa were tested. Data was analyzed using Shapiro-Wilk normality test, Kruskal-Wallis test with α = 0.05. P value ≤ 0.05 was considered as significant. Results The levels of air contamination were from 0 to 2.3×10¹ colony-forming unit (CFU)/m³ for bacteria and for yeast and filamentous fungi were from 0 to 1.8×10¹ CFU/m³. The assessment of office space air samples has shown the following numbers of microorganisms: bacteria from 3.0×10¹ to 4.2×10¹ CFU/m³ and yeast and filamentous fungi from 0 to 1.9×10¹ CFU/m³. For surface contamination the mean bacterial count in ambulances has been between 1.0×10¹ and 1.3×102 CFU/25 cm² and in offices – between 1.1×10¹ and 8.5×10¹ CFU/25 cm². Mean fungal count has reached the level from 2.8×10⁰ to 4.2×10¹ CFU/25 cm² in ambulances and 1.3×10¹ to 5.8×10¹ CFU/25 cm² in offices. The qualitative analysis has revealed the presence of Acinetobacter spp. (surfaces), coagulase – negative Staphylococci (air and surfaces), Aspergillus and Penicillium genera (air and surfaces). Conclusions The study has revealed a satisfactory microbiological quantity of analyzed air and surface samples in both study and control environments. However, the presence of potentially pathogenic microorganisms in the air and on surfaces in ambulances may endanger the medical emergency staff and patients with infection. Disinfection and cleaning techniques therefore should be constantly developed and implemented. Int J Occup Med Environ Health 2017;30(4):617–627
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 4; 617-627
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the impact of atmospheric pressure in different seasons on blood pressure in patients with arterial hypertension
Autorzy:
Kamiński, Marek
Cieślik-Guerra, Urszula I.
Kotas, Rafał
Mazur, Piotr
Marańda, Witold
Piotrowicz, Maciej
Sakowicz, Bartosz
Napieralski, Andrzej
Trzos, Ewa
Uznańska-Loch, Barbara
Rechciński, Tomasz
Kurpesa, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2168335.pdf
Data publikacji:
2016-07-22
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
arterial hypertension
atmospheric pressure
Ambulatory blood pressure monitoring
ABPM
impact of weather on health
weather
Opis:
Objectives Atmospheric pressure is the most objective weather factor because regardless of if outdoors or indoors it affects all objects in the same way. The majority of previous studies have used the average daily values of atmospheric pressure in a bioclimatic analysis and have found no correlation with blood pressure changes. The main objective of our research was to assess the relationship between atmospheric pressure recorded with a frequency of 1 measurement per minute and the results of 24-h blood pressure monitoring in patients with treated hypertension in different seasons in the moderate climate of the City of Łódź (Poland). Material and Methods The study group consisted of 1662 patients, divided into 2 equal groups (due to a lower and higher average value of atmospheric pressure). Comparisons between blood pressure values in the 2 groups were performed using the Mann-Whitney U test. Results We observed a significant difference in blood pressure recorded during the lower and higher range of atmospheric pressure: on the days of the spring months systolic (p = 0.043) and diastolic (p = 0.005) blood pressure, and at nights of the winter months systolic blood pressure (p = 0.013). Conclusions A significant inverse relationship between atmospheric pressure and blood pressure during the spring days and, only for systolic blood pressure, during winter nights was observed. Int J Occup Med Environ Health 2016;29(5):783–792
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 5; 783-792
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies