Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Jaworski, T" wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Fuzzy evaluation of visual connectedness in thermography images of cylindrical surface
Rozmyta ocena spójności wizualnej w obrazach termowizyjnych powierzchni walcowej
Autorzy:
Jaworski, T.
Kucharski, J.
Powiązania:
https://bibliotekanauki.pl/articles/408114.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fuzzy logic
thermovision
thermal image decomposition
visual connectedness
logika rozmyta
termowizja
dekompozycja termografu
spójność wizualna
Opis:
This article presents an idea of visual connectedness measure between components in thermography images of rotating steel roller, cylindrically shaped. Both definition and method of measure calculus is given along with a short discussion.
Artykuł przedstawia metodę oceny spójności wizualnej komponentów temperaturowych w obrazach termowizyjnych obracającego się walca. Zaproponowano definicję oraz metodę wyznaczania wartości oceny spójności.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 1; 24-28
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja przepływu dwufazowego gaz-ciecz oparta na ocenie rozmytej obrazów tomograficznych 3D
Two-phase flow structure identification based on fuzzy assesment of 3D tomographical imaging
Autorzy:
Jaworski, T.
Fiderek, P.
Wajman, R.
Banasiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/408592.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
logika rozmyta
rozmyta ocena obrazów
przetwarzanie obrazów
obrazy przestrzenne
fuzzy logic
fuzzy image assessment
image processing
spatial images
Opis:
Prezentowany artykuł przedstawia wyniki prac nad systemem automatycznego rozpoznawania przepływów dwufazowych gaz-ciecz w rurociągach poziomych i pionowych. Opiera się on na logice rozmytej przy ocenie obrazów przestrzennych z tomografii 3D a następnie na przyporządkowaniu uzyskanych ocen do jednej z klas przepływu.
The following paper presents results of research on automated two-phase flow pattern identification, which is based on a fuzzy assessment of registered spatial images. Such images are obtained from 3D tomography reconstruction algorithms and for each a set of fuzzy-based features is calculated. Finally, acquired features are used to classify obtained image to one of flow regime structures.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2013, 3; 41-48
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm dystrybucji znaczników czasowych dla potrzeb synchronizacji danych z różnych systemów pomiarowych
Algorithm of time stamps distribution for data synchronization of various measurement systems
Autorzy:
Wajman, R.
Jaworski, T.
Fiderek, P.
Banasiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/408610.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
synchronizacja danych pomiarowych
znaczniki czasowe
measurement data synchronization
time stamps
Opis:
Badania opisane w artykule odnoszą się do zakończonego projektu naukowo – badawczego, którego celem było zbudowanie systemu pomiarowego do wyznaczania udziału faz w oparciu o trójwymiarową tomografię pojemnościową 3D ECT. W ramach tych prac przewidziano ocenę własności metrologicznych nowego systemu, w którym zastosowano równolegle wiele metod pomiarowych. Aby możliwe było dokładne porównanie wyników działań każdej z zastosowanych metod, potrzebne było opracowanie jednolitej usługi znaczników czasowych do synchronizacji danych pomiarowych pochodzących z różnych źródeł o różnej prędkości ich akwizycji. Artykuł opisuje zaprojektowany uniwersalny algorytm sieciowej usługi dystrybucji znaczników czasowych.
The described in this paper research refer to the finished project which aimed to build the measurement system for phase distribution calculation and two phase flow structure identification based on 3D ECT system. In the frame of this work the metrological validation of the measurement system was done where many of various measurement technics were applied parallel. In order to analyse the measurement results, there was a need to design the unified service of time stamps distribution for measurement data synchronization. The measured data were collected with different speed. This paper presents the designed universal network algorithm of the time stamps distribution.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2013, 3; 38-40
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozmyta klasteryzacja surowych trójwymiarowych danych tomograficznych dla potrzeb rozpoznawania przepływów dwufazowych
Fuzzy clustering of raw three dimensional tomographic data for two-phase flows recognition
Autorzy:
Fiderek, P.
Jaworski, T.
Wajman, R.
Kucharski, J.
Powiązania:
https://bibliotekanauki.pl/articles/408134.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
logika rozmyta
klasteryzacja rozmyta
trójwymiarowa tomografia pojemnościowa
fuzzy logic
fuzzy clustering
three dimensional capacitance tomography
Opis:
Artykuł zawiera opis wykorzystania klasteryzacji rozmytej dla potrzeb rozpoznawania rodzajów przepływów dwufazowych typu gaz-ciecz. Autorzy przedstawili szczegółowy opis procesu pozyskiwania trójwymiarowych danych tomograficznych, tak zwanych surowych danych tomograficznych, nowych metod gromadzenia, interpretacji oraz statystycznego przetwarzania tego typu danych. Dodatkowo w artykule znajduje się opis podstawowych zagadnień z zakresu logiki rozmytej i klasteryzacji rozmytej takich jak wyznaczanie wektora cech znaczących czy zasady działania klasyfikatora rozmytego (FCM) w odniesieniu do specyficznego rodzaju danych wykorzystanych podczas badań. Uzasadniając wybór klasteryzacji rozmytej autorzy zaprezentowali wyniki przeprowadzanych eksperymentów, które potwierdziły, że algorytmy rozmyte bardzo dobrze nadają się do badań nad zjawiskami o bardzo dynamicznym charakterze, jakimi bez wątpienia są przepływy dwufazowe typu gaz-ciecz.
The paper contains a description of the fuzzy clustering method usage for the recognition of two-phase gas-liquid flows. The authors present a detailed description of the obtaining process of three dimensional tomographic data, the so-called raw tomographic data, and new methods of the data collection, interpretation and statistical processing. In addition, the article includes a description of the key issues in the field of fuzzy logic and fuzzy clustering such as the determination of the primary features vector or the fuzzy classifier (FCM) principle of use with a specific type of data used in the study. Justifying the choice of fuzzy clustering authors presented the results of experiments carried out, which confirmed that the fuzzy algorithms are very good matched to the study of phenomena of a very dynamic nature, which, definitely, are the two-phase gas-liquid flows.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 4; 12-16
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two-phase flow regime three-dimensonal visualization using electrical capacitance tomography – algorithms and software
Trójwymiarowa wizualizacja struktur przepływów dwufazowych przy użyciu elektrycznej tomografii pojemnościowej – algorytmy i oprogramowanie
Autorzy:
Banasiak, R.
Wajman, R.
Jaworski, T.
Fiderek, P.
Kapusta, P.
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/407785.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
electrical capacitance tomography
fluid flow measurement
reconstruction algorithm
elektryczna tomografia pojemnościowa
pomiar przepływów
algorytm rekonstrukcji
Opis:
This paper presents the software for comprehensive processing and visualization of 2D and 3D electrical tomography data. The system name as TomoKIS Studio has been developed in the frame of DENIDIA international research project and has been improved in the frame of Polish Ministry of Science and Higher Education Project no 4664/B/T02/2010/38. This software is worldwide unique because it simultaneously integrates the process of tomographic data acquisition, numerical FEM modeling and tomographic images reconstruction. The software can be adapted to specific industrial applications, particularly to monitoring and diagnosis of two-phase flows. The software architecture is composed of independent modules. Their combination offers calibration, configuration and full-duplex communication with any tomographic acquisition system with known and open communication protocol. The other major features are: online data acquisition and processing, online and offline 2D/3D images linear and nonlinear reconstruction and visualization as well as raw data and tomograms processing. Another important ability is 2D/3D ECT sensor construction using FEM modeling. The presented software is supported with the multi-core GPU technology and parallel computing using Nvidia CUDA technology.
W artykule autorzy przedstawiają środowisko komputerowe do kompleksowego przetwarzania i wizualizacji tomograficznych danych pomiarowych. Oprogramowanie TomoKIS Studio powstało w Instytucie Informatyki Stosowanej PŁ w ramach projektu DENIDIA i zostało rozwinięte w ramach projektu MNiSW nr 4664/B/T02/2010/38. Zbudowane oprogramowanie jest unikalne w skali światowej, gdyż integruje w sobie proces pozyskiwania danych pomiarowych, modelowanie numeryczne oraz proces konstruowania obrazów tomograficznych, z możliwością adaptacji dla różnych aplikacji przemysłowych, w szczególności dla potrzeb monitorowania i diagnostyki przepływów dwufazowych gaz-ciecz. Architektura aplikacji oparta jest na zestawie niezależnych modułów, które pozwalają na w pełni dwukierunkową komunikacją, konfigurację oraz kalibrację dowolnego urządzenia tomografii elektrycznej z otwartym protokołem pomiarowym, akwizycję i przetwarzanie danych pomiarowych on-line, liniową oraz nieliniową rekonstrukcję obrazów 2D i 3D w czasie rzeczywistym, a także wizualizację surowych danych pomiarowych i tomogramów. Istotnym elementem systemu jest moduł numerycznego modelowania czujników pojemnościowych wykorzystujący metodę elementów skończonych, oparty na autorskich algorytmach generowania siatek MES komputerowych modeli czujników pojemnościowych. Architektura prezentowanego systemu została zaprojektowana przy użyciu obliczeń równoległych na procesorach graficznych, z wykorzystaniem technologii Nvidia CUDA.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 11-16
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intelligent system for the two-phase flows diagnosis and control on the basis of raw 3D ECT data
Inteligentny system diagnostyki i sterowania przepływami dwufazowymi na podstawie pomiarów 3D ECT
Autorzy:
Fiderek, P.
Jaworski, T.
Banasiak, R.
Nowakowski, J.
Kucharski, J.
Wajman, R.
Powiązania:
https://bibliotekanauki.pl/articles/408515.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fuzzy inference
fuzzy logic
fuzzy control
3D capacitance tomography
raw measurement data analysis
fluid flow measurement and control
wnioskowanie rozmyte
logika rozmyta
sterowanie rozmyte
trójwymiarowa tomografia pojemnościowa
analiza surowych danych pomiarowych
rozpoznawanie i sterowanie przepływu gaz-ciecz
Opis:
In this paper the new intelligent system for two-phase flows diagnosis and control is presented. The authors developed a fuzzy inference system for two phase flows recognition based on the raw 3D ECT data statistical analysis and fuzzy classification which identify the flow structure in real-time mode. The non-invasive three-dimensional monitoring is possible to conduct even in non-transparent and non-accessible parts of the pipeline. Presented system is also equipped with the two phase gas-liquid flows installation control module based on fuzzy inference which includes the feedback information from the recognition module. The intelligent control module working in a feed-back loop keep the sets of required flow regime. Presented in this paper fuzzy algorithms allow to recognize the two phase processes similar to the human expert and to control the process in the same, very intuitively way. Using of the artificial intelligence in the industrial applications allows to avoid any random errors as well as breakdowns and human mistakes suffer from lack of objectivity. An additional feature of the system is a universal multi-touched monitoring-control panel which is an alternative for commercial solution and gives the opportunity to build user own virtual model of the flow rig to efficiently monitor and control the process.
W artykule zaprezentowany został inteligentny system diagnostyki i sterowania przepływami dwufazowymi gaz-ciecz. Autorzy opracowali rozmyty system wnioskowania oparty o statystyczną analizę i klasyfikację rozmytą surowych danych pomiarowych 3D ECT realizujący w czasie rzeczywistym identyfikację struktury przepływu oraz wyznaczanie objętościowego udziału faz. Nieinwazyjny trójwymiarowy monitoring przepływu możliwy jest w nieprzezroczystych i trudno dostępnych fragmentach rurociągów w czasie rzeczywistym. Prezentowany system wyposażony jest również w moduł sterowania instalacją w oparciu o wnioskowanie rozmyte, któremu na wejście podawane są informacje zwrotne od modułu rozpoznawania. Inteligentny regulator rozmyty pracujący w pętli sprzężenia zwrotnego utrzymuje żądane nastawy parametrów przepływu w oparciu o zadany reżim przepływu. Przedstawione w niniejszym opracowaniu algorytmy rozmyte umożliwiają identyfikację procesów dwu-fazowych w sposób analogiczny do tego, jak to robią specjaliści oraz jednocześnie pozwalają kontrolować proces w ten sam bardzo intuicyjny sposób. Zastosowanie sztucznej inteligencji w aplikacjach przemysłowych pozwala uniknąć przypadkowych ludzkich błędów podatnych na brak obiektywizmu, a także zapobiegać awarii. Cechą dodatkową systemu jest uniwersalny dotykowy panel monitorująco-sterujący stanowiący alternatywę dla drogich komercyjnych rozwiązań umożliwiający budowanie wirtualnego modelu instalacji, aby w szybki i skuteczny sposób móc ją monitorować i nią sterować.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 17-23
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System trójwymiarowej tomografii pojemnościowej w zastosowaniu do wyznaczania udziału faz oraz identyfikacji struktur w przepływach mieszanin gaz-ciecz
Application of 3D electrical capacitance tomography for phase fraction determination and structures identification in two-phase flows
Autorzy:
Banasiak, R.
Wajman, R.
Fidos, H.
Fiderek, P.
Jaworski, T.
Nowakowski, J.
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/407787.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
elektryczna tomografia pojemnościowa
trójwymiarowa wizualizacja
przepływ dwufazowy
mieszaniny gaz-ciecz
udział faz
struktury przepływu
electrical capacitance tomography
three-dimensional visualization
two-phase flow
gas-liquid mixtures
phase fraction
flow structures
Opis:
W procesach przemysłowych, w których bezpośrednie monitorowanie jest utrudnione, zastosowanie nieinwazyjnego systemu tomografii pojemnościowej dla identyfikacji struktur przepływów dwufazowych mieszanin gaz-ciecz oraz wyznaczenia udziału faz jest szczególnie ważne. W artykule przedstawiono wyniki badań poświęconych rozwojowi nowych nieinwazyjnych metod identyfikacji i wizualizacji struktur przepływów dwufazowych. Nowe możliwości, jakie niesie ze sobą zastosowanie komputerowych technik tomograficznych w pomiarach wielkości elektrycznych, wyznaczają dziś standardy w pomiarach dynamicznych. Proponowane rozwiązanie zakłada możliwość zastosowania systemu tomograficznego do pomiaru rozkładu koncentracji poszczególnych frakcji procesu. Opracowane algorytmy pozwoliły na szybką trójwymiarową wizualizację wnętrza rurociągów, w których występują przepływy mieszanin gaz-ciecz, poprzez uzyskanie w krótkim czasie obrazów oraz ich szybką analizę i identyfikację. Taka diagnostyka może być użyteczna w kontekście przemysłowych procesów monitorowania oraz sterowania przepływami mieszanin gaz-ciecz w systemach czasu rzeczywistego.
In the industrial processes, where the direct monitoring is difficult, the application of the non-invasive electrical capacitance tomography system for the two-phase gas-liquid mixtures flow structures identification and the phase distribution calculation is of great importance. This paper presents the research results of development new non-invasive diagnostic methods. The new possibilities offered by the tomographic techniques applications for the purposes of the electrical quantities measurement, define today the standards of dynamic measurements. The proposed solution involves the possibility of applying the tomographic system to measure the fractions concentration distribution of the flow. The designed algorithms allowed the fast 3D visualization of the pipeline interior through the quick tomographic image reconstruction and their analysis and structure identification. The obtained diagnostic data could be useful in the context of monitor and control of the flow industrial facilities in the real time.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2013, 3; 28-31
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena metrologiczna systemu pomiarowego dla potrzeb wyznaczania udziału faz w przepływie mieszanin gaz-ciecz metodą tomografii pojemnościowej 3D
Metrological evaluation of measurement system for two-phase flow fractions determination using 3D electrical capacitance tomography
Autorzy:
Wajman, R.
Fidos, H.
Fiderek, P.
Jaworski, T.
Nowakowski, J.
Sankowski, D.
Banasiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/408465.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
przepływ dwufazowy
tomografia pojemnościowa ECT
wizualizacja trójwymiarowa
struktury przepływów
przepływy przemysłowe
two-phase flow
capacitance tomography ECT
three-dimensional visualization
flow structures
industrial flows
Opis:
Przemysłowe systemy diagnostyki i monitorowania potrzebują nowych narzędzi oferujących możliwości nieinwazyjnej obserwacji i analizy procesów przepływów dwufazowych mieszanin gaz-ciecz. Opracowany system pomiarowy dedykowany jest dla potrzeb nieinwazyjnego wyznaczania procentowego udziału faz oraz identyfikacji struktur w przepływach dwufazowych w rurociągach pionowych i poziomych. Artykuł prezentuje wybrane rezultaty prac badawczych, w wyniku, których dokonano oceny własności metrologicznych prototypowego systemu trójwymiarowej tomografii pojemnościowej. Prace badawcze obejmowały między innymi: zagadnienie optymalizacji struktury czujnika ECT, a także metrologiczną ocenę dokładności rekonstrukcji obrazu oraz wyznaczania procentowego udziału faz w porównaniu z innymi metodami. W wyniku przeprowadzonej analizy wykazano dużą przydatność systemu 3D ECT do nieinwazyjnego, szybkiego diagnozowania dynamicznych procesów przepływowych.
The industrial diagnostic and monitoring systems require new methods offering the possibility of non-invasive observation and analysis of the two-phase gas-liquid mixtures flows. The designed new measurement system is dedicated for non-invasive percentage phase distribution calculation and flow structure identification in the vertical and horizontal pipelines. This paper presents some research results of the metrological validation of the designed three-dimensional capacitance tomography measurement system including: the 3D ECT sensor structure optimization, the metrological analysis of the image reconstruction process accuracy and the metrological analysis of the results of the phase distribution calculation method in comparison with other common technics. As a result of performed analysis the height capability of the 3D ECT measurement system for non-invasive real time dynamic flow processes identification was proved.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2013, 3; 49-54
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-dimensional modelling of thermal stresses in a planar solid oxide fuel cell of a novel design
Modelowanie 3D termicznych naprężeń w płaskim stałotlenkowym ogniwie paliwowym o nowatorskiej konstrukcji
Autorzy:
Zinko, T.
Pianko-Oprych, P.
Jaworski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/408754.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
planar Solid Oxide Fuel Cell
thermal stresses
residual stresses
finite element method
computational fluid dynamics (CFD)
płaskie stałotlenkowe ogniwo paliwowe
naprężenie termiczne
naprężenie szczątkowe
Metoda Elementu Skończonego
Numeryczna Mechanika Płynów
Opis:
The presented modelling investigation was carried out to analyze thermal stresses and expansion in an anode supported planar Solid Oxide Fuel Cell (pSOFC). The temperature distribution was based on previously developed thermo-electrochemical model predicting fuel cell operation. The design of a single pSOFC consisted of three ceramic layers of membrane electrode assembly: anode, electrolyte, cathode and two cross-flow bipolar plates with 26 ribs. The gases flowed diagonally from one cell corner to the opposite one. The fuel and air flows were cross-wise opposed on each bipolar plate side. The study allowed to indicate the most vulnerable to thermal damage area of the fuel cell in the operating conditions. The results will be useful in further design modification and performance optimization of the SOFC.
Przeprowadzone symulacje numeryczne miały na celu analizę termicznych naprężeń i ocenę stopnia wydłużenia płaskiego stałotlenkowego ogniwa paliwowego typu pSOFC (ang. planar Solid Oxide Fuel Cell). Rozkład temperatury w ogniwie wyznaczono w oparciu o wcześniej opracowany model termiczno-elektrochemiczny [11]. Nowatorskie rozwiązanie ogniwa typu pSOFC objęło ceramiczną konstrukcję, w skład której weszły porowate elektrody – anoda i katoda, elektrolit oraz dwie płytki bipolarne z 26-cioma żebrami. Przepływ paliwa i powietrza odbywał się krzyżowo i przeciwprądowo, po przekątnej ogniwa. Wyniki symulacji pozwoliły na określenie obszarów ogniwa narażonych na uszkodzenie w wyniku wysokich wartości naprężeń termicznych. Uzyskane rezultaty FEM umożliwią dalszą modyfikację konstrukcji płaskiego ogniwa w celu optymalizacji wydajności pSOFC.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 1; 69-72
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies