Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kwarciak-Kozłowska, A." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Toxicity assessment of treated meat industry wastewater in the anaerobic process
Ocena toksyczności ścieków z przemysłu mięsnego oczyszczonych w procesie beztlenowym
Autorzy:
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/296776.pdf
Data publikacji:
2017
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
meat industry wastewater
toxicity
Lepidium test
ASBR reactor
biogas purification
ścieki z zakładu mięsnego
toksyczność
test Lepidium
reaktor ASBR
oczyszczanie biogazu
Opis:
Major pollutant components of meat processing wastewater are biodegradable organic compounds, fats and proteins in both particulate and dissolved forms. Because of the possible pollution of water sources, the efficient disposal of effluent from meat plants is important. The treatment of industrial wastewater is a highly complex process that generally involves factors associated with load fluctuations and high concentrations of organic matter. Toxic effects on aquatic organisms and plants may be caused by numerous nitrogen compounds, as well as detergents and antibiotics, in the meat industry wastewater. The aim of the research was to determine the toxicity of anaerobic treated meat industry wastewaters. The level of toxicity was determined with algae growth inhibition test and Lepidium test. The values of ErC50 (0÷96) and EbC50 of indicators were 18.4 and 8.6% respectively. TU value for ErC50 was 5.51 which meant acute toxicity of wastewater. The value of TU for EbC50 was 11.62 (high toxicity of wastewater). The values of indicators RSG (relative seed germination), RRG (relative root growth) and GI (germination index) were 92, 19.5 and 17.62% respectively. Treatment efficiency meat industry wastewater during fermentation process was very high. The COD and BOD removal efficiency were on 82.3 and 80% respectively. Effluent from ASBR reactor had following parameters: COD - 206 mg O2/dm3 and BOD - 130 mg/dm3. TOC value after anaerobic process was 75 mg C/dm3 (78.1%). The concentration of ether extract and proteins were 188 and 74 mg/dm3respectively. Generated biogas in the methane fermentation process of wastewater from meat industry plants was characterized by a high methane content (77.5% vol.). Carbon dioxide and the ballast in the analyzed biogas were 20 and 2.5% respectively. In order to enrich biomass with methane by removal of CO2 from its content, the gas generated in the anaerobic process was subjected to the processes of chemisorption and adsorption on the granulated active carbons and molecular sieve. Purification the raw biogas by a molecular sieve has contributed to the increase of methane in enriched from 77.5 to 92.6% and the removal of CO2 from 20 to 5.7%. Due to poor quality and its high toxicity, effluent from ASBR reactor can not to be discharged into natural water. In the future it is suggested to incorporate RO or UF into the technological system in order to posttreatment the wastewater.
Głównymi zanieczyszczeniami obecnymi w ściekach powstających na terenie zakładu mięsnego są biodegradowalne związki organiczne, tłuszcze i białka, występujące w nich zarówno w formie cząstek stałych, jak i rozpuszczonych. Ze względu na możliwość zanieczyszczenia nimi naturalnych odbiorników ważne jest skuteczne oczyszczanie tego rodzaju ścieków poprodukcyjnych. Oczyszczanie ścieków przemysłowych jest bardzo złożonym procesem, na który wpływa wiele czynników, m.in. wysokie stężenie materii organicznej w ściekach, jak również duże ich wahania. Działanie toksyczne na organizmy wodne i rośliny może być spowodowane przez występujące w ściekach z przemysłu mięsnego związki azotu, a także detergenty i antybiotyki. Celem badań było określenie toksyczności beztlenowo oczyszczonych ścieków z przemysłu mięsnego. Poziom ich toksyczności określono za pomocą testu zahamowania wzrostu glonów oraz testu Lepidium. Wartości wskaźników ErC50 (0-96) i EbC50 wynosiły odpowiednio 18,4 i 8,6%. Wartość TU dla ErC50 wynosiła 5,51, co oznaczało ostrą toksyczność ścieków. Wartość TU dla EbC50 wynosiła 11,62 (wysoka toksyczność ścieków). Wartości wskaźników RSG (względne kiełkowanie nasion), RRG (względny wzrost korzeni) oraz GI (wskaźnik kiełkowania) wynosiły odpowiednio 92, 19,5 i 17,62%. Efektywność oczyszczania ścieków z przemysłu mięsnego w procesie fermentacji metanowej była bardzo wysoka. Stopień usunięcia ChZT i BZT5 był na poziomie odpowiednio 82,3 i 80%. Odpływ z reaktora ASBR charakteryzował się następującymi wartościami: ChZT - 206 mg/dm3 i BZT5 - 130 mg/dm3. Wartość OWO po procesie beztlenowym obniżyła się do poziomu 75 mg C/dm3 (78,1%). Stężenie ekstraktu eterowego i białek w ściekach oczyszczonych wynosiło odpowiednio 188 i 74 mg/dm3. Wytworzony w procesie fermentacji metanowej ścieków z zakładu mięsnego biogaz charakteryzował się wysoką zawartością metanu (77,5% obj.). Zawartość ditlenku węgla i balastu w analizowanym biogazie wynosiła odpowiednio 20 i 2,5%. W celu wzbogacenia biogazu w metan poprzez usunięcie z jego zawartości CO2 wytworzony w procesie beztlenowym gaz poddano procesom chemisorpcji i adsorpcji na granulowanych węglach aktywnych oraz na sicie molekularnym. Oczyszczanie surowego biogazu za pomocą sita molekularnego przyczyniło się do wzrostu zawartości metanu z 77,5 do 92,6% przy jednoczesnym usunięciu CO2 z 20 do 5,7%. Z powodu jednak złej jakości odpływu z reaktora ASBR oraz jego wysokiej toksyczności ścieki tak oczyszczone nie mogą być odprowadzane do odbiornika naturalnego. W przyszłości w celu ich doczyszczania sugeruje się włączenie procesu RO lub UF do układu technologicznego.
Źródło:
Inżynieria i Ochrona Środowiska; 2017, 20, 4; 509-523
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biofiltracja jako metoda unieszkodliwiania odorów powstających podczas kompostowania frakcji biodegradowalnej odpadów komunalnych i przemysłowych
Neutralization of odors generated during composting of biodegradable fraction of municipal and industrial waste by biofiltration
Autorzy:
Kwarciak-Kozłowska, A.
Bańka, B.
Powiązania:
https://bibliotekanauki.pl/articles/297263.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
kompostowanie
odpady biodegradowalne
biofiltracja
odory
biofiltr
composting
biodegradable waste
biofiltration
odor
biofilter
Opis:
W artykule zaprezentowano zagadnienia związane z emisją związków zapachowych podczas kompostowania bioodpadów. Ze względu na skład gazów i charakter emitowanych związków w procesie kompostowania, a także niskie koszty i łatwą eksploatację biofiltracja wydaje się jedną z korzystniejszych metod dezodoryzacji w obiektach gospodarki odpadami. Biofiltracja wpisuje się w trend rozwoju zrównoważonego w dziedzinie neutralizacji zapachów drogą biologiczną bez używania reagentów chemicznych. Proces biologiczny opiera się na zasadzie reakcji utleniania związków w obecności tlenu i mikroorganizmów, dzięki czemu powstają biomasa, woda oraz produkty mineralne. Dzięki temu procesowi można uzyskać dobre efekty usuwania typowych zanieczyszczeń emitowanych z kompostowni (siarkowodór, amoniaki i lotne związki organiczne). Skuteczność usuwania H2S i amoniaku osiąga wartości bliskie 98%. W przypadku usuwania lotnych związków organicznych efektywność biofiltrów jest niższa i wynosi średnio 50%.
The paper presents the issues associated with the emission of aroma compounds during composting of biowaste. Biological methods for purification of air from volatile organic compounds such as biofiltration are effective and competitive in relation to the adsorption or absorption of thermal and catalytic combustion. This type of decontamination procedure does not require any substantial additional amounts of problematic substances and the quantities of waste generated is small. Due to the composition and nature of the gases emitted in the process of composting of the compounds, as well as low cost and easy operation of the biofiltration this method appears to be one of the more preferred ones in case of deodorization of waste management facilities. The essence of the biofilter is based on the degradation of contaminants by aerobic microorganisms contained in the filter material (biomass) disposed in the biofilter. Biological waste gas treatment is based on two main processes, which are the absorption of pollutants in water and biological decomposition of pollutants absorbed. Both processes take place at the same time and the effect of their common impact assessments is that the gases are purified by absorbing in the biological decomposition of pollutants sorbent regeneration. The purified gases might not involve inhibiting substances (including heavy metals or toxins), and their temperature must be within the range tolerated by the microorganisms colonizing the membrane biofilter filling. Decomposition of organic compounds using biofilters is carried out to CO2 and H2O with the participation of aerobic heterotrophic microorganisms. Autotrophic bacteria are capable of removing inorganic compounds from gases such as hydrogen sulfide and ammonia. Through this process you can get good results removing common pollutants emitted from the composting plant (hydrogen sulfide; ammonia and volatile organic compounds). The removal efficiency can reach 99% and 98% for hydrogen sulfide and ammonia respectively. In the case of the removal of volatile organic compounds biofilter efficiency is lower and amounts to an average of 50%.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 4; 631-645
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of the organic fraction of pretreated leachate from old landfill after sonication exposure
Charakterystyka frakcji organicznej odcieków ze starego składowiska po zastosowaniu sonifikacji
Autorzy:
Kwarciak-Kozłowska, A.
Sławik-Dembiczak, L.
Powiązania:
https://bibliotekanauki.pl/articles/297739.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
landfill leachate
IR spectra
ultrasound field
biodegradation
odcieki składowiskowe
spektroskopia IR
pole ultradźwiękowe
biodegradacja
Opis:
Collection of municipal waste in landfills, even properly designed and operated, is an important issue in environmental engineering. These are formed by the infiltration of rainfall through the waste bed and eluting with the organic and inorganic compounds, often toxic nature. So far, over 200, have been identified which are organic substances leachate contamination, as many as 35 belongs to the so-called “priority pollutants”. By the decrease in the concentration of organic compounds in the leachate decrease the value of biological and chemical oxygen demand which is dictated by stabilization of landfill as lengthening the time of its life. However, the indicator BOD5 decreases faster as compared to COD therefore BOD5/COD ratio is reduced to as low as 0.06. The leachate produced in mature landfills appears to be the presence of significant amounts of humic acid with very stable structure difficult to breach by bacteria. It was assumed that ultrasonic waves induce change in the structure of organic compounds and contribute to the acceleration of the biodegradability, among other substances in the effluents refractive thereby improve the efficiency of the biological purification processes. For sonification leachate used ultrasonic disintegrator type vibro goal Sonics (40 kHz). The range of vibration amplitude was varied in the range from 25 to 123 μm and exposure time (sonification of leachate) from 60 to 720 seconds. Also the measuring of the size of the energy produced during sonication sonochemical leachate was made. It was found, inter alia, that the sonification process of effluents clearly influenced the formation and release of aliphatic compounds. The –CH2 and –CH3 groups can be released from the humic compounds or aromatic combinations. It was also observed the formation of substantial amounts of compounds with the functional hydroxyl group, which might be derived from alcohols and carboxylic acids. These changes suggested a breach of the chemical structure of organic compounds contained in the leachate, so that, the chemical structure of the formed compounds was more susceptible to biodegradation. The study also determined the effect of ultrasonic field on the evolution of the BOD5 treated leachates and BOD5/COD ratio. The BOD5 sharp increase was observed at the time of sonification of leachate in the range of 60 to 300 s in the whole studied range of amplitudes. This suggests that by the action of the ultrasonic field generated in the effluents of chemical compounds had greater biodegradability.The process confirmed by the change in the ratio of BOD5/COD. The highest value of BOD5 indicator (460 mg/dm3) was at the time of subjecting the leachate impact of ultrasound using amplitude equal to the size of 25 μm and for the time of sonification equal 300 s. In this case the BOD5/COD factor increased to 0.12, and it was about 26% higher as compared to the value of this indicator for leachate no-sonificated (0.089).
Gromadzenie odpadów komunalnych na składowiskach, nawet prawidłowo zaprojektowanych i eksploatowanych, jest istotnym zagadnieniem w inżynierii środowiska z uwagi na problemy ochrony wód gruntowych przed zanieczyszczeniem odciekami. Odcieki powstają w wyniku infiltracji opadów atmosferycznych przez złoże odpadów i wymywanie z niego związków organicznych i nieorganicznych, niejednokrotnie o charakterze toksycznym. Dotychczas zidentyfikowano ponad 200 substancji organicznych będących zanieczyszczeniami odcieków, z których aż 35 należy do tzw. „priority pollutants”. W miarę upływu czasu wskutek obniżania się stężenia związków organicznych w odciekach zmniejszają się wartości biologicznego i chemicznego zapotrzebowania tlenu, co związane jest ze stabilizacją składowiska w miarę wydłużania czasu jego eksploatacji. Wskaźnik BZT5 szybciej maleje w porównaniu z ChZT, w związku z czym stosunek BZT5/ChZT ulega zmniejszeniu nawet do poziomu 0,06. W odciekach powstających na „starych” składowiskach odnotowuje się obecność znacznych ilości kwasów humusowych charakteryzujących się bardzo stabilną strukturą trudną do naruszenia przez bakterie. Dlatego też efektywność ich oczyszczania metodą biologiczną osadu czynnego lub fermentacji metanowej nie jest zbyt wysoka. Założono, że fale ultradźwiękowe wywołają zmianę struktury związków organicznych i przyczynią się do przyśpieszenia biodegradowalności, między innymi substancji refrakcyjnych w odciekach, dzięki czemu wzrośnie efektywność ich oczyszczania w procesach biologicznych. Do nadźwiękawiania odcieków użyto dezintegratora ultradźwiękowego typu Sonisc vibro cel (40 kHz). Zakres wartości amplitud drgań zmienił się od 25 do 123 μm, a czas ekspozycji (nadźwiękawiania odcieków) od 60 do 720 s. Podczas sonifikacji dokonywano również pomiaru wielkości energii sonochemicznej wytwarzanej podczas nadźwiękawiania odcieków. Stwierdzono m.in., że proces sonifikacji odcieków wyraźnie wpłynął na powstawanie i uwolnienie związków alifatycznych. Grupy –CH2 i –CH3 mogły być uwalniane ze związków humusowych lub połączeń aromatycznych; zaobserwowano również powstawanie znacznych ilości związków z grupą funkcyjną –OH, które mogły być pochodnymi alkoholi i kwasów karboksylowych. Zmiany te wskazują na naruszenia struktury chemicznej związków organicznych zawartych w odciekach, wskutek czego powstawały związki o strukturze chemicznej bardziej podatnej na proces biodegradacji. W badaniach określono także wpływ pola ultradźwiękowego na zmiany wskaźnika BZT5 oczyszczanych odcieków oraz na stosunek BZT5/ChZT. Wyraźny wzrost BZT5 obserwowano w momencie nadźwiękawiania odcieków w zakresie od 60 do 300 s w całym przebadanym zakresie amplitud. Sugeruje to, że wskutek oddziaływania pola ultradźwiękowego na odcieki powstają w nich związki chemiczne o większym stopniu biodegradowalności. Zachodzący proces potwierdziła zmiana wartości stosunku BZT5/ChZT. Najwyższą wartość 460 mg/dm3 wskaźnik BZT5 przyjął w momencie poddawania odcieków oddziaływaniu ultradźwięków przy zastosowaniu wielkości amplitudy równej 25 μm i dla czasu nadźwiękawiania 300 s. Współczynnik BZT5/ChZT w tym przypadku wzrósł do poziomu 0,12 i był on o 26% wyższy w porównaniu do wartości tego wskaźnika dla odcieków nienadźwiękawianych (0,089).
Źródło:
Inżynieria i Ochrona Środowiska; 2016, 19, 4; 561-575
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies