Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "proces oczyszczania" wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
Removal of PAHs from municipal wastewater during the third stage of treatment
Usuwanie WWA ze ścieków komunalnych w trzecim etapie oczyszczania
Autorzy:
Włodarczyk-Makuła, M.
Wiśniowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/297035.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
PAHs
GC-MS
wastewater
oxidation process
hydrogen peroxide
WWA
ścieki
proces utleniania
Opis:
The investigations were carried out using wastewater received from a municipal wastewater treatment plant. The samples of wastewater were primarily characterized for concentration of selected physicochemical parameters. Next, a standard mixture of PAHs was added to the samples. Chemical oxidation process was performed using two doses of hydrogen peroxide. Changes in concentration of PAHs were determined in the wastewater samples before addition of the chemical reagent and after the oxidation process. A quantitative analysis of PAHs was provided by GC-MS. The extraction of organic matrices from the wastewater samples was performed using a mixture of organic solvents: methanol, cyclohexane and dichloromethane. The extracts were separated from samples, purified on silica gel and concentrated under nitrogen stream. Concentrations of 16 PAHs according to EPA were determined. The detection limit ranged from 0.14 to 0.59 μg/L. Total concentration of 16 PAHs in wastewater sampled from the treatment plant were 1.4 μg/L on average. Total concentration of 16 PAHs in wastewater with the standard mixture was 561 μg/L on average. A decrease in PAHs concentration was observed in the samples after chemical oxidation process. Addition of hydrogen peroxide resulted in a decrease of 16 PAHs concentration in wastewater coming from the wastewater treatment plant to 61÷74%. The efficiency of hydrocarbons removal, grouped according to the number of rings, ranged from 35 to 90%.
Celem badań było określenie efektywności usuwania WWA ze ścieków podczas ich doczyszczania. W pracy przedstawiono wyniki badań zmian ilościowych WWA w poddawanych utlenianiu ściekach komunalnych oczyszczonych odpływających z miejskiej oczyszczalni ścieków. Oczyszczalnia pracuje jako mechaniczno-biologiczna z chemicznym usuwaniem fosforu. Badania prowadzono po wprowadzeniu do ścieków oczyszczanych dodatkowej ilości WWA w postaci standardowej mieszaniny. Następnie prowadzono proces utleniania zanieczyszczeń organicznych ze szczególnym uwzględnieniem zmian w stężeniu WWA, z wykorzystaniem nadtlenku wodoru. Utleniacz stosowano w postaci 30% roztworu w dawkach wynoszących 2,5 i 5 mg/dm3. Efektywność usuwania WWA określano z uwzględnieniem zawartości początkowej badanych związków oraz dodanej w postaci wzorca. Analizowano stężenia 16 WWA zgodnie z listą EPA. Oznaczenia jakościowo-ilościowe prowadzono z wykorzystaniem chromatografu gazowego ze spektrometrem masowym. W procesie utleniania odnotowano znaczny spadek stężenia badanych WWA w ściekach. Ubytek sumarycznej ilości WWA w ściekach wzbogaconych WWA był w zakresie od 61 do 74%, lecz dla poszczególnych węglowodorów efektywność usunięcia wahała się od 35 do 90%.
Źródło:
Inżynieria i Ochrona Środowiska; 2018, 21, 2; 143-154
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fouling membran półprzepuszczalnych podczas oczyszczania wody metodą ultra- i mikrofiltracji - przegląd piśmiennictwa
The fouling of semi-permeable membranes during water treatment by use of UF/MF proces - review
Autorzy:
Bodzek, M.
Płatkowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/296721.pdf
Data publikacji:
2009
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
NOM
fouling
membrany
HPSEC
SEM/AFM
FTIR
koagulacja
PAC
membranes
coagulation
Opis:
Procesom membranowym uzdatniania wody i oczyszczania ścieków towarzyszy nieodłącznie zjawisko zmniejszania wydajności i żywotności membran zwane foulingiem. Pierwszym krokiem do ograniczenia foulingu jest poznanie natury tego zjawiska. Pozwalają na to dostępne techniki analityczne, takie jak: SEM, AFM, FTIR, HPSEC, analiza OWO, ASA, pomiar kąta zwilżenia oraz potencjału elektrokinetycznego membran czy też frakcjonowanie na żywicach XAD8/4. Stopień foulingu powodowanego przez NOM uzależniony jest m.in. od siły jonowej oraz pH. Zależy on w dużej mierze od właściwości filtrowanej wody, w tym hydrofilowości/hydrofobowości jej składników. Duża część badaczy obarcza frakcję hydrofobową odpowiedzialnością za fouling. Dla procesów niskociśnieniowych zaobserwowano wpływ rozmiaru cząstek filtrowanej frakcji (im mniejsze, tym większy obserwowany spadek strumienia oraz opór filtracji) na zjawisko foulingu. Zidentyfikowano 4 kategorie NOM, które uważane są za silne foulanty, a mianowicie białka, aminocukry, polisacharydy i związki poli(hydroksy-aromatyczne). Znaczenia ma również rodzaj membrany. W zdecydowanej większości prac zaobserwowano większą tendencję do foulingu w przypadku membran hydrofobowych niż hydrofilowych, co tłumaczono adsorpcją ujemnie naładowanych grup funkcyjnych NOM na dodatnio naładowanych powierzchniach membrany. Obecnie stosowane są różne procesy wstępnego przygotowania nadawy, mające na celu zwiększenie jakości wody i/lub wydajności membran. Koagulacja oraz adsorpcja na węglu aktywnym są polecane przy minimalizacji foulingu związanego z dużymi stężeniami poli(hydroksy-aromatów), proces utlenienia natomiast jest zalecany do zmniejszania foulingu powodowanego polisacharydami.
During membrane water and wastewater processes reduction of capacity and membranes lifetime can be observed. Those phenomena are caused by membrane fouling. To limit the influence of fouling on the efficiency of membrane processes detailed recognition of its nature is required. This can be done using available analytical technologies like: electron microscopy (SEM, AFM), infrared spectroscopy (FTIR), high performance size exclusion chromatography (HPSEC), TOC analysis, atomic absorption spectroscopy (AAS), measurement of contact angle and zeta potential or fractionation on XAD8/4 resins. The influence of fouling caused by NOM mainly depends on ionic strength and pH, but also on properties of filtrated water, including hydophobicity/hydrophilicity of its components. Resent scientific reports suggest that the hydrophobic water fraction has a significant impact on fouling. Size of molecules of filtrated fraction is responsible for fouling occurring fouling during low-pressure membrane processes (the smallest size of molecules the highest flux decline). 4 categories of NOM, which are considered to be strong foulants, were identified. They include: proteins, aminosugars, polysaccharides and poly(hydroxy-aromatics). The membrane composing material also has a meaning. Hydrophobic membranes seem to have greater ability to fouling than hydrophilic ones. It can be explained by the fact, that the positively charged membrane surface tends to adsorb negatively charged functional groups of NOM. Nowadays different water pretreatment processes are applied. Their aim is to improve water quality and/or membrane capacity. Fouling caused by poly(hydroxyl-amines) can be minimized by coagulation or adsorption on activated carbon, while oxidation reduces the fouling induced by polysacharides.
Źródło:
Inżynieria i Ochrona Środowiska; 2009, 12, 1; 5-24
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies on integrated process of microfiltration and photocatalysis used in laundry wastewater treatment
Badania wstępne nad zintegrowanym procesem mikrofiltracji i fotokatalizy stosowanym do oczyszczania ścieków pralniczych
Autorzy:
Polak, D.
Szwast, M.
Powiązania:
https://bibliotekanauki.pl/articles/297597.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
integrated process
microfiltration
photocatalysis
laundry wastewater
proces zintegrowany
mikrofiltracja
fotokataliza
ścieki pralnicze
Opis:
Industrial laundries generate wastewater in very large quantities. This wastewater is characterized by a high value of chemical oxygen demand (COD) and it contains substances suspended in the liquid that are responsible for wastewater turbidity. Furthermore, wastewater from industrial laundries contains several grams of detergents per litre of washing substances, mostly surfactants. Environmental and legal requirements force factories, including industrial laundries, to look for new and cost-effective methods of wastewater treatment. In the case of wastewater from industrial laundries, it is also important that a treatment method involves closing of the water loop in the plant and allows the plant to recover some of the detergents to be reused in another washing cycle. In order to address the problems related to wastewater from industrial laundries, the authors proposed an integrated process, which combined microfiltration and photocatalytic oxidation. This study presents preliminary results of the research carried out on actual wastewater generated in an industrial laundry. Results demonstrated the possibility of recovery of large amounts of purified water with detergents for the subsequent washing cycles. Thus, the integrated system of microfiltration and photocatalysis can be used in the technology of recovering water and detergents from industrial laundries. This technology enables to eliminate turbidity and remove some detergents associated with contamination caused by washing processes. Furthermore, purification degree is sufficient to reuse water in the pre-wash cycle.
Ścieki w pralniach przemysłowych produkowane są w bardzo dużych ilościach. Ścieki te charakteryzują się dużą wartością parametru ChZT (Chemiczne Zapotrzebowanie Tlenu), zawierają substancje zawieszone w cieczy i odpowiedzialne za mętność tych ścieków. Ponadto w ściekach z pralni przemysłowych znajdują się znaczne ilości (do kilku gramów w litrze) środków piorących, w szczególności środków powierzchniowo czynnych. Wymagania środowiskowe i prawne zmuszają zakłady, w tym pralnie przemysłowe, do poszukiwania nowych, oszczędnych metod oczyszczania ścieków. W przypadku ścieków z pralni przemysłowych istotne jest również to, aby metoda oczyszczania uwzględniała zamknięcie obiegu wody w zakładzie i pozwalała na odzysk przynajmniej części detergentów i ich użycie w kolejnym cyklu prania. Do rozwiązania tak postawionego problemu wobec ścieków pochodzących z pralni przemysłowych autorzy zaproponowali zastosowanie zintegrowanego procesu, w skład którego wchodzi mikrofiltracja oraz utlenianie fotokatalityczne. Praca przedstawia wstępne wyniki badań prowadzonych na rzeczywistych ściekach powstałych w pralni przemysłowej. Wyniki wskazują na możliwość zawrócenia dużych ilości oczyszczonej wody wraz z detergentami do kolejnych cyklów pralniczych. Zatem zintegrowany system złożony z procesu mikrofiltracji i fotokatalizy może zostać wykorzystywany w technologii odzyskiwania wody i detergentów z pralni przemysłowych. Technologia ta umożliwia całkowite usunięcie mętności oraz części detergentów związanych z zanieczyszczeniami z prania. Dodatkowo stopień oczyszczenia jest wystarczający, by ponownie wykorzystać wodę do prania wstępnego.
Źródło:
Inżynieria i Ochrona Środowiska; 2018, 21, 2; 163-170
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies