Tytuł:
PC-based high frequency imaging system with coded excitation
Autorzy:
Lewandowski, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331588.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
coded transmission
SNR
FPGA
Opis:
Coded transmission is a technique that gives significant improvement in SNR and enables higher contrast imaging without sacrificing the resolution. A novel HF (20-35 MHz) ultrasound real-time imaging system for research and evaluation of the coded transmission was developed. The digital programmable coder-digitizer module based on the field programmable gate array (FPGA) chip supports arbitrary waveform coded transmission and RF echoes sampling up to 200 MSPS. A novel balanced software architecture supports real-time RF processing and display at rates up to 30 frames/sec. The system was used to gather data for sine burst and 16-bit Golay code excitation using a single element scanning head with thick film focused spherical transducer 25 MHz center frequency and 56% system bandwidth. SNR gain for the Golay codes (referenced to single burst) of 15 dB for 20 MHz and 16 dB for 35 MHz were obtained. In water the axial resolution for both single burst and the Golay codes was the same FWMH=20 ns at 20 MHz and FWMH=15 ns at 35 MHz. The presented system is a practical and low cost implementation of coded excitation technique in HF ultrasound imaging.
Źródło:
Hydroacoustics; 2008, 11; 239-247
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cumulative method of the image reconstruction in synthetic aperture. Experimental results
Autorzy:
Wójcik, J.
Trots, I.
Lewandowski, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331922.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
An analytical model of imaging using synthetic aperture (SA) methods is presented. This model takes into account: fundamental features of an environment, of an electric transmission/reception path and a description of SA structure – possible schemes of transmission, reception and image formation. Then two schemes are analyzed: a proposed cumulative synthetic transmit aperture (CSTA) and for comparison of the standard STA schemes. For both methods identical basic parameters – equal sequences of transmit and receive transducers were applied. The distinctive feature of CSTA is gathering (summing up) echoes of subsequent transmissions in one acquisition matrix sufficient for image reconstruction. In traditionally applied STA methods a separate acquisition matrix for each transmission is created. Therefore there are a dozen to several dozen more matrices and the time of image reconstruction is at least several times longer than in CSTA. The presented experimental results obtained using wire and tissue mimicking phantoms have shown the comparable imaging quality in both methods.
Źródło:
Hydroacoustics; 2012, 15; 195-206
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of trabecular bone properties using ultrasonic scanne
Autorzy:
Cieślik, L.
Litniewski, J.
Lewandowski, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331888.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
Signals scattered in trabecular bone contain information about properties of the bone structure. Evaluation of this properties may be essential for osteoporosis diagnosis and treatment monitoring because the standard densitometry does not provide complete information about the bone strength. It was previously demonstrated that using numerical model of backscattering in trabecular bone it is possible to estimate some microstructural characteristics of bone. Model predicts departures from the Rayleigh statistics of the scattered signal envelope depended on the scatterer physical parameters and its shape uniformity. This study concerns examination of trabecular bone (calcaneus) in vivo. Ultrasonic bone scanner operating at frequency of 1,5 MHz was used to collect backscattered signals. Data were processed in order to obtain the statistical properties of the signal envelope and to compare them with histograms resulting from modeling. This study is an approach towards developing a tool for the investigation of scattering in trabecular bone that can potentially provide clinically useful information about bone strength and condition.
Źródło:
Hydroacoustics; 2010, 13; 39-52
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preeliminary results: comparison of different schemes of synthetic aperture technique in ultrasonic imaging
Autorzy:
Sęklewski, M.
Karwat, P.
Klimonda, Z.
Lewandowski, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331979.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
The Synthetic Aperture (SA) methods are widespread and successfully used in radar technology, as well as in the sonar systems. The advantages of high framerate and its relatively good resolution in the whole area of scanning, make this technique an object of interest in medical imaging methods such as ultrasonography (US). This paper describes the possible usage of the SA method in ultrasound imaging. The introduction to the principles of the SA technique in ultrasonography is presented. The measurements of different SA schemes were conducted using the set-up consisting of the research ultrasonograph module, the PC and the special wire phantom. The results for different schemes of image reconstruction are presented. Particularly the Synthetic Transmit Aperture (STA) technique was concerned. Results of the STA method are discussed in this paper.
Źródło:
Hydroacoustics; 2010, 13; 243-252
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the transducer bandwidth and double pulse transmission on the encoded imaging ultrasound
Autorzy:
Trots, I.
Nowicki, A.
Lewandowski, M.
Secomski, W.
Litniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/331651.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
encoded imaging ultrasound
ultrasound imaging transducer
CGS
Opis:
An influence effect of fractional bandwidth of ultrasound imaging transducer on the gain of compressed echo signal being the complementary Golay sequences (CGS) with different spectral widths is studied in this paper. Also, a new composing transmission method of CGS is discussed together with compression technique applied in order to increase the signal-to-noise ratio (SNR) and penetration. The CGS with two different bit lengths, one-cycle and two-cycles are investigated. Two transducers with fractional bandwidth of 25% and 80% at centre frequency 6 MHz are used. The experimental results are presented, clearly proofing that increasing of the code length leads to compressed echo amplitude enhancement. The smaller the bandwidth is the larger is this effect; the pulse-echo sensitivity of the echo amplitude increases by 1.88 for 25% fractional bandwidth and 1.47 for 80% while preserving time resolution. The presented results of double transmission of short codes show the penetration and SNR improvement while maintaining dead zone.
Źródło:
Hydroacoustics; 2008, 11; 419-430
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistics of envelope of high frequency ultrasound signal backscattered in human dermis
Autorzy:
Piotrzkowska, H.
Litniewski, J.
Szymańska, E.
Lewandowski, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331987.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
The scattering of ultrasonic waves depends on the size, shape, acoustical properties and concentration of scatterers in tissue. In these study K distribution of the ultrasound backscatter envelope was used to assess the structural properties of the skin tissue. The custom-designed high frequency ultrasonic scanner was applied to obtain RF B-scans of the skin in vivo at the frequency of 20 ÷ 30MHz. The results are encouraging. The K distribution models the envelope statistics very well. The parameters of the K-distribution, namely, the effective number of scatterers may be useful for the skin characterization.
Źródło:
Hydroacoustics; 2010, 13; 205-214
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of radial artery reactive response using high frequency ultrasound
Autorzy:
Nowicki, A.
Secomski, W.
Trawiński, Z.
Lewandowski, M.
Trots, I.
Szubielski, M.
Olszewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/332584.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
thick film transducers
atherosclerosis
flow mediated vasodilation
Opis:
Background: There is a growing interest in the application of non-invasive clinical tools allowing one to assess the endothelial function, preceding atherosclerosis. The precision in estimating of the artery Flow Mediated Vasodilation (FMD) using standard 10-12 MHz linear array probes does not exceed 0.2 mm, far beyond that required. Methods: We have introduced a wide-band, high frequency 25-30 MHz, Golay encoded wobbling type imaging to measure dilation of the radial artery instead of the brachial one. 18 young volunteers, and 4 volunteers with cardiac events history, were examined. In the second approach 20 MHz linear scanning combined with 20 MHz pulsed Doppler attached to the linear array was used. The radial artery FMD was normalized using shear rate at the radial artery wall. Results and Conclusions: For the “healthy” group, the FMD resulting from reactive hyperemia response was over 20%; while in the “atherosclerotic” group, the FMD was at least twice as small, not exceeding 10%. The shear rate (SR) normalized FMDSR was in the range from 7.8 to 9.9 in arbitrary units, while in patients with minor cardiac history FMDSR was clearly lower, 6.8 to 7.6. The normalized FMDSR of radial artery RARR can be an alternative to the brachial FMD where the precision of measurements is lower and the diameter dilation does not exceed 7-10%.
Źródło:
Hydroacoustics; 2016, 19; 297-306
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies