Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wyroby" wg kryterium: Temat


Tytuł:
I-SCAN Method for the Assessment of Pressure Exerted by Textile Products
Metoda I-SCAN w ocenie nacisku wywieranego przez wyroby włókiennicze
Autorzy:
Cieślak, M.
Karaszewska, A.
Gromadzińska, E.
Śledzińska, K.
Powiązania:
https://bibliotekanauki.pl/articles/234053.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
textiles
pressure measuring
knitted structures
wyroby włókiennicze
wyroby pończosznicze
ocena nacisku
Opis:
The capabilities of the I-SCAN (TekScan) system for pressure measurements were tested in in vivo and in vitro condition using hosiery articles at a pressure of 18-21mmHg, as declared by the manufacturers. For two types of knee-length socks with the same structure and slight difference in composition (polyamide/elastomer 78/22% and 64/36%) the pressure was measured on the ankle and calf in four positions (1-front, 2-inner side, 3-back, 4-outer side). The highest pressure values were found for the 1-front position and the lowest for the 2-inner side position. It was shown that there is a correlation between the in vivo and in vitro tests. The I-SCAN method allows to take measurements in various place and to create maps of the pressure distribution.
Nacisk wyrobów włókienniczych może powodować niepożądany wpływ na użytkownika lub działać profilaktycznie. W obu przypadkach ocena nacisku wymaga odpowiednich metod dostosowanych do przeznaczenia wyrobu. Badano możliwości systemu I-SCAN (TekScan) w warunkach in vivo i in vitro, na przykładzie wyrobów pończoszniczych należących do pierwszej klasy nacisku 18-21mmHg. W przeciwieństwie do powszechnie stosowanych metod, metoda I-SCAN bazująca na elastycznych matach pomiarowych umożliwia pomiar w dowolnym miejscu i tworzenie map nacisku. Dla dwóch rodzajów podkolanówek o zbliżonym składzie (poliamid/elastomer 78/22% i poliamid/elastomer 64/36%), i takiej samej strukturze zmierzono nacisk na wysokości kostki i łydki w czterech pozycjach (1–przód, 2-strona wewnętrzna, 3–tył, 4–strona zewnętrzna). Największy nacisk na kostce i łydce występował w pozycji 1-przód, a najmniejszy w pozycji 2-strona wewnętrzna. Wykazano, że dla metody I-SCAN istnieje korelacja między badaniami in vivo i in vitro.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 6 (120); 121-127
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accelerated Ageing of the Implantable, Ultra-Light, Knitted Medical Devices Modified by Low-Temperature Plasma Treatment – Part 1. Effects on the Physical Behaviour
Badania przyspieszonego starzenia implantowalnych, ultra lekkich, dzianych wyrobów medycznych modyfikowanych powierzchniowo plazmą nisko temperaturową – Część 1. Wpływ na właściwości fizyczne
Autorzy:
Struszczyk, M. H.
Gutowska, A.
Pałys, B
Cichecka, M
Kostanek, K
Wilbik-Hałgas, B.
Kowalski, K.
Kopias, K.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/233165.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
implants
ultra-light medical devices
knitted structures modification
low-temperature plasma
physical behaviour
starzenie implantów
wyroby medyczne
właściwości fizyczne
dziane wyroby medyczne
Opis:
The aim of the research was to validate the effects of accelerated ageing on the physical properties of newly-designed ultra-light three dimensional (3-D) knitted implants undergoing one-sided modification by low-temperature plasma treatment using low molecular weight fluoroorganic donors. The influence of storing the knitted medical devices for 1 or 2 years at accelerated conditions was studied taking into account their selected physical properties in relation to key usable features. The presented study is a continuation of previous research for the elaboration of a new-idea of three-dimensional implants applied in hernioplasty (general surgery), vaginoplasty and urinary incontinence treatment (urologynaecology).
Celem prowadzonych badań była walidacja wpływu przyspieszonego starzenia na fizyczne właściwości nowo opracowanej konstrukcji ultralekkich, trójwymiarowych dzianych implantów poddanych jednostronnej modyfikacji nisko temperaturową plazmą w obecności niskocząsteczkowego związku fluoroorganicznego. Ocenie poddano wybrane kluczowe z punktu widzenia aspektów użytkowych, właściwości fizyczne zaprojektowanych dzianych wyrobów medycznych poddanych procesowi przyspieszonego starzenia. Prezentowana praca stanowi kontynuację wcześniejszych badań dotyczących opracowania trójwymiarowych implantów stosowanych w rekonstrukcji przepuklin (chirurgia ogólna), plastyce pochwy lub do chirurgicznego leczenia nietrzymania moczu (urologinekologia).
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 121-127
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Thermal-Insulating Parameters in Two- and Three-Layer Textiles with Semi-Permeable Membranes
Analiza parametrów izolacyjności cieplnej dla dwu- i trójwarstwowych wyrobów włókienniczych z membranami półprzepuszczalnymi
Autorzy:
Sybilska, W.
Korycki, R.
Powiązania:
https://bibliotekanauki.pl/articles/232283.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
membrane products
thermal-insulating parameters
membrana
wyroby odzieżowe
parametry cieplno-izolacyjne
Opis:
The main goal of paper presented was to evaluate clothing products (including products coated by semi-permeable membranes) in respect of thermal comfort. To achieve this, the thermal-insulating parameters were measured using an Alambeta measuring instrument. The research program introduced a set of diversified materials of different raw material composition, membranes applied, weave, density etc. The test results were analyzed in respect of the thermal-insulating parameters of multilayer products, particularly the membrane effect as a separating and protective layer.
Podstawowy cel prezentowanego artykułu to ocena wyrobów odzieżowych (włącznie z wyrobami z naniesionymi membranami półprzepuszczalnymi) pod kątem komfortu cieplnego. Parametry izolacyjności cieplnej były mierzone za pomocą przyrządu pomiarowego Alambeta. Program badań uwzględnia zestaw zróżnicowanych materiałów o różnych: składzie surowca, zastosowanych membranach, splocie, gęstości itp. Wyniki badań były analizowane z uwagi na parametry izolacyjności cieplnej wyrobów wielowarstwowych, szczególnie wpływ membrany jako warstwy rozdzielającej i ochronnej.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 5 (119); 80-87
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on the Melt Processing of Biodegradable Aliphatic-Aromatic Polyester into Fibrous Products
Badania przetwórstwa stopowego biodegradowalnych poliestrów alifatyczno-aromatycznych na wyroby włókniste
Autorzy:
Twarowska-Schmidt, K.
Sulak, K.
Gałęski, A.
Piórkowska, E.
Wojtczak, M.
Dutkiewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/231912.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
biodegradable polyester
fibrous products
spunbond nonwoven
poliester biodegradowalny
wyroby włókiennicze
włókniny spunbond
Opis:
Research is described in the article concerning the melt processing of biodegradable aliphatic-aromatic copolyesters into fibrous products. Copolyesters containing 57 - 60% of a tri-component aliphatic portion (copolymers of butylene glycol and adypic-, succinic-, glutaric acid and terephtalic acid) prepared on a large laboratory scale were used in fibres and nonwoven from molten polymers. Fibres were made in a two-step process comprising spinning and drawing. Nonwovens were formed by the spunbond method. Main properties are given of the polymers and fibres, and the nonwoven made thereof. It was found that the aliphatic-aromatic copolyesters prepared reveal good spinability. Thermal properties: Tg < 0 °C and low Tm ~115 °C of fibres made of aliphatic-aromatic copolyesters limit their possible uses mainly to the production of disposables. A cheap method of making spunbond nonwoven which leads to ready textiles is recommended for the processing of the copolyesters.
W pracy opisano badania dotyczące przetwórstwa stopowego biodegradowalnego alifatyczno-aromatycznego kopoliestru na wyroby włókniste. Kopoliestry zawierające 57-60% trójskładnikowej części alifatycznej (kopolimery glikolu butylenowego i kwasów adypinowego, bursztynowego, glutarowego oraz kwasu tereftalowego) wytworzone w skali wielkolaboratoryjnej wykorzystano do formowania włókien i włóknin bezpośrednio ze stopu polimeru. Włókna wytwarzano w dwuetapowym procesie składającym się z przędzenia i rozciągania. Włókniny formowano metodąspod filiery (spun bonded). Podano podstawowewłaściwości polimerów oraz otrzymanych z nichwłókien i włóknin. Stwierdzono, żeopracowane ko poliestry alifatyczno-aromatyczne wykazują dobrą przędliwość. Z uwagi na właściwości termiczne: Tg < 0 °C oraz niską T m ~115 °C włókna z alifatyczno-aromatycznych kopoliestrówmogą być stosowane w ograniczonym zakresie, przede wszystkim na wyroby jednorazowego użytku. Ze względów ekonomicznych bardziej wskazany jest przerób tych polimerów na gotowe wyroby włókiennicze, np. włókniny spun bonded.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 6 (120); 58-64
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Prospect of Textile Technologies for Medical Devices
Ocena perspektyw technologii włókienniczych wyrobów medycznych
Autorzy:
Struszczyk, M. H.
Olejnik, M.
Powiązania:
https://bibliotekanauki.pl/articles/234260.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
wyroby medyczne
technologie włókiennicze
ubieranie
implanty
medical devices
textile technologies
foresight
dressing
implants
Opis:
This article includes the assessment of fibrous medical devices as well as borderline products from the point of view of expenditures necessary for the realisation of research and implementation in industrial and clinical practices, the range of practice implementation benefits as well as potential barriers restricting studies and implementation. The scale of investment necessary for the realisation of research and implementation in industrial practices in relation to the benefits of implementing them in practice as well as the limitations that restrict the research and implementation of selected fibrous technologies for medical devices are discussed in detail.
W artykule omówiono technologie włókienniczych wyrobów medycznych biorąc pod uwagę poziom koniecznych nakładów na realizację badań oraz wdrożenie rezultatów tych badań, skalę korzyści wdrożenia do praktyki oraz ewentualne, zidentyfikowane zgodnie z obecnym stanem wiedzy, bariery ograniczające procesy badawcze oraz komercjalizacyjne. Oszacowano także obecny stan zaawansowania badań nad włókienniczymi wyrobami medycznymi w kraju i za granicą wraz z próbą oceny stopnia ich gotowości do wdrożenia do praktyki i przewidywanego okresu komercjalizacji.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6A (95); 28-36
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of Long-lasting Relaxation Properties of Polyester Yarns and Fabrics
Przewidywanie długotrwałych procesów relaksacyjnych przędz poliestrowych PET i wykonanych z nich tkanin
Autorzy:
Milašius, R
Laureckiene, G
Powiązania:
https://bibliotekanauki.pl/articles/233966.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
stress relaxation
polyester yarn
textile
długotrwały proces relaksacyjny
przędza poliestrowa PET
tkanina
wyroby włókiennicze
Opis:
Relaxation properties are very important for various kinds of textiles and especially for technical ones. Technical textiles in their usage sometimes undergo stress for a long time and their behaviour after which is very important for prediction of the possibility for their further usage. For the prediction of such properties and long-lasting relaxation investigation, the relative stress relaxation P/P0, which characterizes the rate of relaxation, is used. In the present paper it was found that this rate cannot be described as a linear dependency on the logarithm of the time – in a certain time the character of the rate changes. Such a phenomenon is clearly visible for multifilament polyester yarns as well as for woven fabrics from them. The time in which the character of the rate of relaxation changes is herein proposed to be named as the break-point of the relaxation process. In our work it was found that the break-point of polyester (PET) yarns and fabrics exist after 100 seconds. It was also discovered that the rate of relaxation in the log(t) scale can be described by two straight lines and the values of relaxation in the long term can be predicted by the rate of relaxation of the second linear dependency. A method which allows to predict the relaxation process up to 200,000 seconds after testing till 500 seconds is presented. The reliability of such a prediction is lower than 2%.
Znajomość procesów relaksacyjnych jest bardzo ważna dla wyrobów włókienniczych, zwłaszcza dla wyrobów technicznych. Techniczne tekstylia w czasie ich użytkowania podlegają długotrwałym obciążeniom i znajomość przebiegów relaksacyjnych, w tym względnej wartości P/Po charakteryzującej szybkość relaksacji jest bardzo ważna. Stwierdzono, że szybkość ta nie może być opisana liniową zależnością funkcji od logarytmu czasu. Po pewnym czasie przebiegu relaksacji szybkość ulega zmianie. Można ją natomiast opisać dwoma przebiegami liniowymi zmieniającymi swój charakter w tak zwanym punkcie przełamania. Przebiegi te przedstawiono dla włókien poliestrowych (PET) i wykonanych z nich tkanin. W tym przypadku zmiana następuje po 100 sekundach. Określenie tej zależności pozwala na przewidywanie długotrwających zmian relaksacji przy zbadaniu jedynie krótkiego przedziału czasowego. Stwierdzone zależności są słuszne tylko dla włókien PET.
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 6 (108); 97-100
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototypes of Primary Wound Dressing of Fibrous and Quasi-Fibrous Structure in Terms of Safety of Their Usage
Prototypy opatrunków o strukturze włóknistej i quasi-włóknistej w zakresie bezpieczeństwa ich użytkowania
Autorzy:
Kucharska, M.
Struszczyk, M. H.
Cichecka, M
Brzoza-Malczewska, K.
Wiśniewska-Wrona, M
Powiązania:
https://bibliotekanauki.pl/articles/233815.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
wound dressings
fibrous structure
biopolymers
preclinical studies
risk assessment
parametry bezpieczeństwa
materiały opatrunkowe
wyroby medyczne
Opis:
The subject of this paper is the evaluation of the critical usability parameters and the parameters characterising the safety of selected prototypes of dressing materials on featuring fibrous, quasi-fibre and hybrid structures, developed at the Institute of Biopolymers and Chemical Fibres (IBWCh). Primary sterile dressing materials were evaluated for usability, which determines the user’s safety and physiological comfort according to a series of PN-EN 13726 standards, harmonised with the EU Directive on medical devices, before and after the accelerated ageing process. The scope of the research was developed based on identifying potential threats arising from the expected clinical application of the medical devices being designed. It allowed for the determination of the impact of selected physical and mechanical parameters, needed from a utility point of view, on the properties of the final medical devices, and the elaboration of the documentation of risk analysis, according to the guide described in Standard PN-EN ISO 14971:2011.
Przedmiotem artykułu jest ocena krytycznych parametrów użytkowych i parametrów charakteryzujących bezpieczeństwo wybranych prototypów materiałów opatrunkowych o strukturach włóknistych, quasi-włóknistych i hybrydowych, opracowanych w Instytucie Biopolimerów i Włókien Chemicznych (IBWCh). Sterylne specjalistyczne materiały opatrunkowe zostały poddane ocenie właściwości użytkowych charakteryzujących bezpieczeństwo i komfort fizjologiczny użytkownika zgodnie z serią norm PN-EN 13726 zharmonizowanych z Dyrektywą UE o wyrobach medycznych przed i po procesie symulowanego starzenia. Przeprowadzone badania, których zakres został opracowany dzięki identyfikacji potencjalnych zagrożeń wynikających z przewidywanego klinicznego zastosowania projektowanych wyrobów medycznych, pozwoliły na ustalenie wpływu wybranych parametrów fizyko-mechanicznych, niezbędnych z użytkowego punktu widzenia, na właściwości gotowych wyrobów medycznych oraz przygotowanie dokumentacji analizy ryzyka zgodnie z wymogami normy PN-EN ISO 14971:2011.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 142-148
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Status and Scope of the Jute Industry in India in Comparison to other World Producers
Analiza produkcji włókien z juty i wyrobów jutowych w Indiach w porównaniu do innych producentów światowych
Autorzy:
Bag, S. N.
Kumar, U. C.
Pal, A. K.
Powiązania:
https://bibliotekanauki.pl/articles/234020.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
twill
bags
hessian
jute goods
sacking
diagonal
torby
włókno jutowe
wyroby z juty
worki jutowe
Opis:
India is the leading producer of raw jute and jute products in the world. India’s sacking goods production comprises 75% of the total goods production and B twill bags, used for packaging rice and wheat, and contributes 85% of the total sacking bag production. Still there exists an increasing trend of imports of jute products due to the increase in the domestic consumption of conventional jute goods. Bangladesh is the major exporter in jute goods, with India in 2nd position. Hessian cloth and bags are the major exporting items of jute goods from India. In the overall situation, there exists a unique opportunity of the jute industry to improve the social and economic conditions of the states concerned as well as the country. Being the preferred sector in raw jute production due to suitable topographical conditions, emphasis now needs to be placed on modernization of the jute sector with a view to developing a viable and efficient jute manufacturing sector in the country.
Indie są wiodącym producentem włókien jutowych i produktów z juty. Indie produkują 75%-85% światowej produkcji worków opakunkowych. Istnieje wzrastający trend zużycia worków jutowych w związku ze zwiększającym się zapotrzebowaniem krajowym. Drugie miejsce w produkcji wyrobów jutowych zajmuje Bangladesz. Istnieją korzystne warunki do dalszej poprawy rozwoju przemysłu juty, w tym zwiększenie modernizacji i wydajności przemysłu.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 6 (120); 19-25
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Principal Component Analysis to Boost the Performance of an Automated Fabric Fault Detector and Classifier
Zastosowanie analizy składników dla poprawy działania automatycznego detektora i klasyfikatora błędów płaskich wyrobów włókienniczych
Autorzy:
Eldessouki, M
Hassan, M
Qashqary, K
Shady, E
Powiązania:
https://bibliotekanauki.pl/articles/231790.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
fabric fault detector
image processing
artificial neural networks
principal component analysis
wyroby włókiennicze
defekty materiałów
sztuczne sieci neuronowe
analiza głównych składowych
Opis:
There is a growing need to replace visual fabric inspection with automated systems that detect and classify fabric defects. The digital processing of fabric images utilises different methods that offer a large set of image features. The correlation between those features lead to problems during fabric fault classification and reduces the performance of the classifiers. This work extracted a combination of statistical (spatial) and Fourier transform (spectral) features from fabric images of the most frequent faults. Principal component analysis (PCA) was implemented to reduce the dimensionality of the input feature dataset, which achieved a reduction to 36% of the original data size while preserving 99% of information in the original dataset. The features processed using the PCA were fed to an artificial neural network (ANN) to classify the fault categories and then compared to another ANN that worked with the whole feature dataset. The performance of the network that was implemented after application of the PCA increased to 90% of the correct classification rate as compared to 73.3% for the other network.
Istnieje wzrastająca potrzeba zamiany wizualnej inspekcji płaskich wyrobów włókienniczych automatyzowanymi systemami , które będą w stanie rozpoznać i sklasyfikować defekty materiału. Dla cyfrowej obróbki obrazów tkanin stosuje się różne metody oferujące identyfikacje całego zestawu właściwości obrazu. Korelacja pomiędzy tymi właściwościami prowadzi do problemów podczas identyfikacji i klasyfikacji błędów materiałów i redukuje sprawność klasyfikacji. W pracy wyselekcjonowano kombinacje statystycznych (przestrzennych) i fourierowskch (spektralnych) transformacji pozwalających na wyróżnienie zobrazów materiałów najczęściej występujących błędów. W dalszej części pracy usiłowano zredukować ilość danych wejściowych oraz zastosowano dwa różne systemy sztucznych sieci neuronowych. Wynikiem wszystkich poczynań było zdecydowane zwiększenie skuteczności wykrywania błędów.
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 4 (106); 51-57
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Issues Regarding the Design of Textile Compression Products for Small Body Circumferences
Problematyka projektowania wyrobów uciskowych dla małych obwodów ciała
Autorzy:
Ilska, A.
Kowalski, K.
Kłonowska, M.
Kowalski, T. M.
Sujka, W.
Powiązania:
https://bibliotekanauki.pl/articles/233911.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
compression products
unit pressure
body circumference
dimensional tolerance
Laplace law
wyroby uciskowe
nacisk jednostkowy
obwód ciała
tolerancja wymiarowa
prawo Laplace'a
Opis:
On the basis of models developed, an analysis was made of the impact of the seam and adopted manufacturing tolerances of a compression product on the value of unit pressure depending on the longitudinal rigidity of a compression fabric for relatively small body circumferences. Algorithms were developed using Laplace's law and can be applied for designing textile compression products connected by seams, with an intended value of unit pressure. The research results allowed to formulate some general guidelines for designing compression products for relatively small body circumferences.
Na podstawie opracowanych modeli dokonano analizy wpływu szwu i założonych tolerancji wykonania wyrobu uciskowego na wartość nacisku jednostkowego w zależności od wartości sztywności rozciągania dzianiny uciskowej dla względnie małych obwodów ciała. Opracowane algorytmy z wykorzystaniem prawa Laplace’a mogą być wykorzystane do projektowania wyrobów uciskowych łączonych szwem o zamierzonej wartości nacisku jednostkowego. Przedstawione wyniki badań umożliwiły sformułowanie wytycznych do projektowania wyrobów uciskowych dla obwodów ciała o względnie małych wymiarach.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 6 (120); 116-120
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accelerated Ageing of Implantable, Ultra-Light, Knitted Medical Devices Modified by Low-Temperature Plasma Treatment - Part 2. Effect on Chemical Purity
Badania procesu przyspieszonego starzenia implantowalnych, ultra-lekkich dzianych wyrobów medycznych zmodyfikowanych niskotemperaturową plazmą - Część 2. Wpływ symulowanych warunków przyspieszonego starzenia na czystość chemiczną
Autorzy:
Jóźwicka, J.
Gzyra-Jagieła, K.
Gutowska, A.
Struszczyk, M.
Kostanek, K.
Cichecka, M.
Wilbik-Hałgas, B.
Kowalski, K.
Kopias, K.
Ciechańska, D.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/232105.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ultra-light knitted implants
accelerated ageing
chemical purity
leachable substances
ultra lekkie dziane wyroby medyczne
przyśpieszone starzenie się wyrobów medycznych
czystość chemiczna
Opis:
The impact of simulated storage conditions (accelerated ageing) for the chemical purity of innovative ultra-light textile implants (knitted) designed for use in urogynaecology and general surgery (procedures in the treatment of female incontinence, in hernia treatment and vagina plastic surgery) was estimated. The chemical purity of the knitted implants designed: untreated and with low-temperature plasma surface treatment in the presence of the fluoroorganic compounds was estimated. The acceptability of the risk related to the impact of storage conditions on the chemical purity of the implant products was simulated. The examination was based on Standard PN-EN ISO 10993-18:2008: “Biological evaluation of medical devices - Part 18: Chemical characterisation of materials” and was assessed in accordance with Polish and European standards.
W niniejszej pracy dotyczącej badań w zakresie oceny czystości chemicznej zaprojektowanych implantowalnych wyrobów medycznych oszacowano profil substancji wymywalnych w warunkach symulowanego użycia (specyficzne warunki przetwarzania i przechowywania, natura i czas kontaktu wyrobu) w oparciu o wytyczne norm europejskich zharmonizowanych z Dyrektywami europejskimi odnoszącymi się do wyrobów medycznych. Ustalono wpływ symulowanych warunków przechowywania (przyspieszonego starzenia) na czystość chemiczną innowacyjnych ultra-lekkich implantów włókienniczych (dzianin) z przeznaczeniem na implantowalne wyroby medyczne do potencjalnego zastosowania w urologinekologii i chirurgii ogólnej (procedury zaopatrywania nietrzymania moczu u kobiet, procedury zaopatrywania przepuklin i plastyki pochwy u kobiet). Wybrane prototypy wyrobów medycznych poddano procesowi przyspieszonego starzenia zgodnie z programem badań opartym o wytyczne normy ASTM 1980F:2002. Ocenie czystości chemicznej poddano zaprojektowane implanty dziane o powierzchni modyfikowanej plazmą niskotemperaturową w obecności związku fluoroorganicznego oraz implanty niemodyfikowane plazmą. Dokonano oceny akceptowalności ryzyka w zakresie wpływu symulowanych warunków przechowywania na czystość chemiczną zaprojektowanych implantowalnych wyrobów medycznych. Badania przeprowadzono w oparciu o procedury badawcze opracowane zgodnie z normatywami polskimi i europejskimi.
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 3 (105); 133-139
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Knitted Multi-Functional Clothing - the Main Part of a Textile Incubator for Premature Babies
Dziany ubiór wielofunkcjyjny jako część inkubatora tekstylnego dla dzieci przedwcześnie urodzonych
Autorzy:
Szałek, A.
Mikołajczyk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/233201.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
premature babies
knitted pro-medical products
textile incubator
knitted multifunctional mat
controlled microclimate
wcześniaki
dziane wyroby medyczne
Inkubator tekstylny
wielofunkcyjna mata z dzianiny
Opis:
This publication presents an innovative concept for the construction of a textile incubator. A literature study was conducted concerning care for premature babies at neonatology intensive care units. Based on the physiological requirements of preterm infants, a textile incubator model was designed and manufactured. The incubator presented is composed of several layers of material. The primary function of the incubator is to maintain thermal, sensory and humidity comfort, to cool the newborn in case of programmed therapeutic hypothermia, as well as to maintain hospital sterilisation. In the first stage of work on the textile incubator we were focused on problems of the production and maintenance of heat inside the product and cooling the newborn. The most important element of the incubator construction is the heating- cooling – moistening mat, the aim of which is to deliver or receive heat from the premature baby, and to maintain adequate environmental moisture. Because the construction of the humidification mechanism is quite complicated, it is not presented in this publication. The assumed extreme values of temperatures of the functional mat are in the following ranges: for additional heating - such as stationary incubators Tmax = 39 °C, with a precision of 1 °C; in the case of cooling in the medical hypothermia planned Tmin = 29 °C, with a precision of 1 °C. The mat was made in the form of a 3D structure of three-layer weft knitted fabric with channels, manufactured on a cylindrical rib-knitting machine, needle gauge E20. Technological and structural parameters of the three-layer knitted mat manufactured were defined. A test stand for the analysis of heat transfer of the heating mat was designed and constructed.
Przedstawiono innowacyjną koncepcje budowy tekstylnego inkubatora. Przeprowadzono studium literaturowe w aspekcie sposobów opieki nad wcześniakami na oddziałach intensywnej terapii neonatologii. W oparciu o wymagania fizjologiczne wcześniaków został zaprojektowany i wykonany model tekstylnego inkubator. Przedstawiony inkubator składa się z kilku warstw materiałowych. Podstawową funkcją tekstylnego inkubatora jest utrzymanie komfortu termicznego, sensorycznego, wilgotności, schładzanie noworodka w przypadku programowanej hipotermii leczniczej oraz zachowania sterylizacji szpitalnej. Najważniejszym elementem budowy inkubatora tekstylnego jest mata grzewczo – chłodząco - nawilżająca, która ma za zadanie dostarczać lub odebrać ciepło od wcześniaka oraz utrzymać odpowiednie środowisko wilgoci. W tym celu zaprojektowano i wykonano trójwarstwową rządkową dzianinę kanałową 3D, na szydełkarce cylindrycznej dwułożyskowej o numerze uiglenia E 20. Zdefiniowano parametry technologiczne i strukturalne wykonanej dzianej maty trójwarstwowej. Zaprojektowano i wykonano stanowisko badawcze do analizy transportu ciepła maty grzewczej.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 4 (118); 140-147
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antimicrobial Characteristics of Pulsed Laser Deposited Metal Oxides on Polypropylene Hydroentangled Nonwovens for Medical Textiles
Właściwości przeciwdrobnoustrojowe włóknin polipropylenowych pokrytych tlenkami metali stosowanych w wyrobach medycznych
Autorzy:
Ramamurthy, P.
Chellamani, K. P.
Dhurai, B.
ThankaRajan, S. P.
Subramanian, B.
Santhini, E.
Powiązania:
https://bibliotekanauki.pl/articles/949467.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
antibacterial activity
metal oxides
pulsed laser deposition
energy dispersive X-ray
EDX
polypropylene
hydroentangled nonwoven
działanie antybakteryjne
tlenki metali
polipropylen
włóknina
wyroby medyczne
Opis:
In this study, an attempt was made to investigate the antimicrobial activity on polypropylene (PP) hydroentangled nonwoven fabrics coated with transition metal oxides. After etching the nonwoven fabrics with RF plasma, nano-scale coatings of ZnO and CuO were done using the KrF excimer based pulsed laser deposition technique (PLD). Morphological and antimicrobial studies were carried out to elucidate the mechanism of antibiocidal behaviour of the coated fabrics. Results showed significant antibacterial activity of ZnO and CuO coated PP hydroentangled nonwovens with a better activity against gram positive S.aureus than gram negative E.coli. Inherently non-toxic, PP has excellent chemical resistance and the use of specialised PP fibres for hydroentangled nonwovens could offer scope in addition to metal oxide coatings; nano-scale biological materials such as enzymes and drugs could add specific functionality for their use as medical textiles.
W pracy podjęto próbę zbadania aktywności przeciwdrobnoustrojowej polipropylenowych włóknin pokrytych tlenkami metali. Przeprowadzono badania morfologiczne i przeciw- drobnoustrojowe powlekanych włóknin. Wyniki wykazały znaczną aktywność antybakteryjną włóknin pokrytych ZnO i CuO, przy czym wyższą aktywność antybakteryjną zaobserwowano wobec bakterii Gram-dodatnich (Staphylococcus ureus), niż wobec Gram-ujemnych (Escherichia coli). Stwierdzono, że zastosowanie nietoksycznego polipropylenu, który charakteryzuje się bardzo dobrą odpornością chemiczną, do wytwarzania włóknin powlekanych tlenkami metali pozwala na otrzymanie funkcjonalnych produktów medycznych.
Źródło:
Fibres & Textiles in Eastern Europe; 2017, 2 (122); 112-119
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspects of Chemical Characterisation of Leachables Profile from Ultra-Light Knitting Textiles for Uses as Medical Implants in Urogynaecology and General Surgery
Aspekty charakterystyki chemicznej substancji wymywalnych z ultralekkich dzianin o potencjalnym zastosowaniu jako implantowalne wyroby medyczne stosowane w urologinekologii i chirurgii ogólnej
Autorzy:
Jóźwicka, J.
Gzyra-Jagieła, K
Struszczyk, M. H.
Gutowska, A.
Ciechańska, D.
Krucińska, I
Powiązania:
https://bibliotekanauki.pl/articles/232383.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ultra-light textile implants for urogynaecology
evaluation of chemical leachable profile
physical-chemical parameters
substancje wymywalne z ultralekkich dzianin
wyroby medyczne
implanty w urologii
Opis:
Ultra-light textiles (knitwear) designed as implantable medical devices for potential uses in urogynaecology (treatment procedures in women incontinence and vagina reconstructions) and general surgery (hernia treatments) are a response to the increasing demand for advanced medical devices in medicine. Chemical profile characterisation of leachable substances is an important factor in the use of the materials influencing their biocompatibility. The implant is made of undesired chemical substances in the main raw-material, and penetration into the tissue may cause local and/or systemic inflammation in the patient’s body. The characterisation and analysis of such substances is therefore essential to secure the safe use of implants. Most important is the characterisation of the matter that is extractable from the designed medical devices. To serve these purpose, ultra-light textile implants designed for potential use in urogynaecology and general surgery were examined concerning the chemical analysis of the undesired substance contained in the main material which constitutes the base of the implant. It was a goal of the work to set optimal parameters for the examination of chemical characterisation of the leachable implant’s material, bearing in mind their safe clinical use. Analysis of the chemical leachable profile was made in accordance with directives of standard PN-EN ISO 10993-18:2008 and some Polish and European testing procedures.
Artykuł przedstawia innowacyjne ultra-lekkie implanty włókiennicze w postaci dzianiny z przeznaczeniem na implanty do potencjalnego zastosowania w urologinekologii i chirurgii ogólnej (procedury zaopatrywania przepuklin nietrzymania moczu u kobiet i plastyki pochwy). Badano własności?? charakterystyki substancji wymywalnych z projektowanych implantów. Ultralekkie dzianiny poddano ocenie czystości chemicznej pod kątem wpływu ewentualnych substancji wymywalnych na ich bezpieczeństwo kliniczne. Wyznaczono optymalne parametry badań czystości chemicznej implantowalnych wyrobów medycznych. Oceny czystości chemicznej wyselekcjonowanych dzianin dokonano w oparciu o metody badawcze opracowane na podstawie wytycznych normy PN-EN ISO 10993-18:2008: „Biologiczna ocena wyrobów medycznych – Część 18: Charakterystyka chemiczna materiałów” (ISO 10993-18:2009) oraz opracowanych procedur badawczych na bazie normatywów polskich i europejskich.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 128-134
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Frictional Characteristics of Medical Wipes in Contact with Mechanical Skin Equivalents
Badanie właściwości ciernych gaz chirurgicznych podczas kontaktu z mechanicznymi odpowiednikami skóry
Autorzy:
Ramamurthy, P.
Chellamani, K. P.
Dhurai, B.
Subramaniam, V.
Powiązania:
https://bibliotekanauki.pl/articles/233152.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
hydroentangled nonwoven
kinetic friction
mechanical skin equivalent
viscose
surface roughness
static friction
tribology
wipe
wyroby włókiennicze
tarcie kinetyczne
mechaniczny odpowiednik skóry
wiskoza
chropowatość powierzchni
Opis:
The optimum surface and frictional properties of textiles depend on their specific application. In this study, we examined the frictional behaviour of medical wipes against 15 mechanical near skin equivalents using synthetic leather material and bovine leather. The frictional behaviour characteristics, both static and kinetic, were evaluated at four different normal loads. It was seen that the static and kinetic frictional coefficients decrease with an increasing normal load for all the reference candidates studied. Higher friction was experienced for the movement of the cotton and viscose wipe against leather than that for synthetic polyurethane (PU) and silicone material. The friction of the wipe against any equivalent skin material was found to be dependent on its surface nature and the morphology of the material against which it is in contact and moves. Friction is necessary in real-time use for a wipe to have an inherent frictional resistance for movement against skin during use.
Optymalna powierzchnia i właściwości cierne wyrobów włókienniczych zależą od ich przeznaczenia. W pracy zbadano właściwości cierne gaz chirurgicznych podczas kontaktu z mechanicznymi odpowiednikami skóry, do badań użyto syntetycznych materiałów skórzanych oraz skórę bydlęcą. Określono statyczne i kinetyczne współczynniki tarcia przy czterech różnych obciążeniach. Zaobserwowano, że oba współczynniki tarcia maleją wraz ze wzrostem obciążenia. W przypadku skóry uzyskano wyższy współczynnik tarcia, niż dla poliuretanu i materiału silikonowego. Stwierdzono, że współczynnik tarcia zależy od charakteru powierzchni i morfologii materiału, z którym styka się gaza.
Źródło:
Fibres & Textiles in Eastern Europe; 2017, 2 (122); 120-127
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies