Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Deng, L." wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
Assessing soil environmental capacity on different land uses in a suburban area of Chengdu, China
Autorzy:
Yang, W.-L.
Zhou, W.-Y.
Wan, W.-X.
Gou, S.-Z.
Zhang, J.
Deng, S.-H.
Shen, F.
Wang, Y.-J.
Yang, H.
Luo, L.
Powiązania:
https://bibliotekanauki.pl/articles/207670.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
China
soil pollution
heavy metals
soil
vegetables
Chiny
zanieczyszczenie gleby
metale ciężkie
gleba
warzywa
Opis:
Wenjiang (China) is the area which undertakes high-intensity planting activities. Additionally, the soil environmental capacity has been a hot area of research as it plays a key role in environmental protection planning, environmental impact assessment and sustainable development. In this paper, the static model of soil environmental capacity is employed to investigate the distribution of residual soil environmental capacity in Wenjiang. The results show that the soil environmental capacity of mercury is the largest for industrial land while it is the lowest in garlic-rice planting areas; the soil environmental capacity of arsenic is the largest in city construction land while it is the lowest in ecological conservation zone; the soil environmental capacity of lead is the largest in city construction land while it is the lowest in garlic-rice planting areas; and the soil environmental capacity of chromium is the largest in city construction land while it is the lowest in garlic-rice planting areas.
Źródło:
Environment Protection Engineering; 2019, 45, 2; 55-67
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ag+/S2O8 2– system for the degradation of aqueous flutriafol
Autorzy:
Yang, H.
Zhou, W.
Yang, L.
Deng, J.
Hu, Q.
Wei, H.
Au, C.
Yi, B.
Powiązania:
https://bibliotekanauki.pl/articles/207760.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chemical analysis
degradation
free radicals
metal ions
molecular orbital
transition metals
analiza chemiczna
degradacja
wolne rodniki
jony metali
orbital molekularny
metale przejściowe
Opis:
The degradation of flutriafol in aqueous persulfate (S2O82–) system in the presence of selected transition metal ions was investigated. In the presence of Ag+ or Fe2+, flutriafol degradation occurs, whereas in the presence of Mn2+, Co2+, Ni2+, Cu2+, Zn2+ and Bi3+ ions, the degradation is less than 15%. The Ag+/ S2O82– aqueous system being the most effective was adopted for experimental and theoretical investigations. It was confirmed that pH of 3.0 is the most suitable, and that both · SO4and ·OH– radicals are the main active species to afford flutriafol degradation, with the former contributes more than the latter. To elucidate degradation mechanism, molecular orbital calculations were performed and reaction intermediates identified by GC/MS and HPLC/MS/MS analyses. Three degradation pathways are proposed that involve the cleavage of C–N and C–C bonds as a result of ·SO4 attack, as well as the formation of hydroxylated products due to · OH radicals.
Źródło:
Environment Protection Engineering; 2018, 44, 2; 57-72
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application the optimization models to analysis of the industrial pollutant emission in China
Autorzy:
Zhang, Z.
Liu, G.-D.
Guo, H.
Liu, L.
Deng, S.-H.
Powiązania:
https://bibliotekanauki.pl/articles/950041.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
industrial emissions
air pollution
mathematical models
sulfur dioxide
air pollutant emission
environmental indicators
industrial pollutants
smoke emission
emisja przemysłowa
zanieczyszczenie powietrza
model matematyczny
dwutlenek siarki
ditlenek siarki
emisja zanieczyszczeń powietrza
wskaźniki środowiskowe
zanieczyszczenia przemysłowe
emisja dymu
Opis:
An industrial planning is made based on the optimization model. Factor analysis was used to reject relativity among the environmental indicators. Then, thirty nine industries were clustered into four clusters. Lastly, optimization model was used to plan the industrial structure. Adjusting the industrial structure, it is difficult to reduce vast SO2, smoke, and dust with total industrial output value growth; the air pollutant emission only can be decreased by 10%. The parameters of smoke emission are limited constrains for the optimization. The reasonable and feasible way to solve the problem is to introduce the lower smoke emission technique of the cluster 2 and 4 industries.
Źródło:
Environment Protection Engineering; 2013, 39, 1; 87-99
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies