Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stainless steel" wg kryterium: Wszystkie pola


Wyświetlanie 1-12 z 12
Tytuł:
Electropolymerized polymer coatings for stainless steel
Autorzy:
Trzaskowska, P.
Piechna, M.
Ciach, T.
Powiązania:
https://bibliotekanauki.pl/articles/283988.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
polymers
stainless steel
electropolymerization
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 98
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bactericidal properties of Cu doped TiO2 films deposited on medical stainless steel
Autorzy:
Sobczyk-Guzenda, A.
Owczarek, S.
Jakubowski, W.
Jędrzejczak, A.
Gazicki-Lipman, M.
Szymanowski, H.
Powiązania:
https://bibliotekanauki.pl/articles/284706.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stainless steel
RF PECVD technique
biomaterials
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 75
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical properties of wires for medical use made from modified 316LVM stainless steel
Autorzy:
Dybich, Jerzy
Goryczka, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1844738.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Źródło:
Engineering of Biomaterials; 2021, 24, 163; 85
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of surface modification on corrosion resistance of AISI 440B martensitic stainless steel
Autorzy:
Łępicka, M.
Grądzka-Dahlke, M.
Powiązania:
https://bibliotekanauki.pl/articles/284892.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
martensitic stainless steel
surface
corrosion
Źródło:
Engineering of Biomaterials; 2014, 17, no. 128-129; 114-115 [wklejka]
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the differentiation of structural and physicochemical properties of orthodontic wires of AISI 304 stainless steel
Autorzy:
Grygier, D.
Hoppe, V.
Zięty, A.
Rutkowska-Gorczyca, M.
Powiązania:
https://bibliotekanauki.pl/articles/284164.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stainless steel
orthodontics wire
microstructure
Opis:
Wires used for orthodontic arches play a very important role in the process of orthodontic treatment. In combination with the lock attached to the tooth, they move and align the teeth along the set trajectories. Wires of stainless steel are commonly used in orthodontics for several reasons: they are characterised by high resistance to corrosion, high strength and elasticity, formability and a possibility of obtaining defined properties through cold working and annealing during production process. The purpose of the research presented in the work is the analysis of differences of the selected structural properties in the context of corrosion resistance of the orthodontic wire material. The object of the research was edge arches of the 0.016”x0.022” size made of the stainless steel type AISI 304, provided by two different producers: G&H Orthodontics and Adenta. The research methodology involved analysis of chemical and phase composition of the tested alloy, microscopic tests with application of the light and electron microscopy methods, as well as electrochemical direct current measurements. The research presented in the work has shown significant differences in structural and physical-chemical properties of the orthodontic wires made of AISI 304 type stainless steel. Despite the fact, that the tested arches were manufactured of the theoretically the same materials, but by different producers, they significantly differ in chemical composition, metallurgical purity, phase composition and corrosion resistance. In addition, it is worth noticing that the tested materials, in terms of structure, do not meet the normative requirements obligatory for biomaterials.
Źródło:
Engineering of Biomaterials; 2018, 21, 146; 8-13
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the differentiation of structural and physicochemical properties of orthodontic wires of AlSl 304 stainless steel
Autorzy:
Grygier, D.
Hoppe, V.
Zięty, A.
Rutkowska-Gorczyca, M.
Powiązania:
https://bibliotekanauki.pl/articles/284388.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
wires
orthodontic arches
physicochemical properties
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 14
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological evaluation of ZrC coating on stainless steel 316L: are ZrC-coatings suitable for cardio vascular applications?
Autorzy:
Czerwińska, Ewa
Schickle, Karolina
Parlak, Zümray
Grigorev, Nikita
Szparaga, Łukasz
Mydłowska, Katarzyna
Ceynowa, Przemysław
Gilewicz, Adam
Ratajski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/284524.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Źródło:
Engineering of Biomaterials; 2019, 22, no.153; 52
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność korozyjna drutów ze stali nierdzewnej przeznaczonych dla ortopedii
Corrosion resistance of wire made of stainless steel for orthopaeidcs
Autorzy:
Szuła, A.
Przondziono, J.
Walke, W.
Powiązania:
https://bibliotekanauki.pl/articles/284660.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
odporność korozyjna
stal nierdzewna
ortopedia
corrosion resistance
stainless steel
orthopaedics
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 103-105
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adhesion and growth of human osteoblast-like MG 63 cells on titanium and stainless steel samples developed for constructing bone implants
Autorzy:
Stranavova, L.
Bacakova, M.
Bacakova, L.
Fencl, J.
Powiązania:
https://bibliotekanauki.pl/articles/284428.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteoblasts
biomaterials
implants
Opis:
Titanium and stainless steel are strong, corrosion - resistant and biocompatible metals. Thanks to their remarkable properties, they have been in use for a long time in clinical medicine, mainly for constructing and replacing large joints, in particular the bone-anchoring parts, e.g. cups and stems, and also for fabricating orthopaedic screws and splints. In the Czech Republic, these devices are produced by Beznoska Ltd., and are clinically applied in the Orthopaedic Clinic, Bulovka Faculty Hospital in Prague. This study has investigated the biocompatibility of samples made of pure titanium (according to quality standard ISO 5832-2 ) and corrosion-resistant steel (quality standards ISO 5832-1 and AISI 316L), obtained from Beznoska. In addition to Fe, the steel samples contained C (max. 0.025 wt. %), Si (0.6 wt. %), Mn (1.7 wt. %), P( max. 0.025 wt. %), S(max. 0.003 wt. %), Cr (17.5 wt. %), Ni (13.5 wt. %), Mo (2.8 wt. %), and Cu (max. 0.1 wt. %). The materials were used in the form of square samples (9x9 mm or 30x30 mm, thickness 1 mm ). Both Ti and steel samples were grinded with SiO2. The surface of the steel samples was then treated by polishing with Al2O3 paste (grain size up to 1 μm), while the surface of the Ti samples, i.e. a material not suitable for polishing, was finished by brushing using another type of Al2O3 paste with slightly larger grains. Thus, the surface of the steel samples was finally smoother and glossy, while the Ti surface was rougher and matted. For the in vitro biocompatibility tests, human osteoblast-like MG 63 cells (European Collection of Cell Cultures, Salisbury, UK) were used. The smaller samples (9 x 9 mm) were inserted into polystyrene 2 4-well cell culture plates (TPP, Trasadingen, Switzerland; well diameter 1.5 cm). Each well contained 25000 cells (approx. 14150 cells / cm 2 ) and 1.5 ml of Dulbecco’s Modified Eagle Minimum Essential Medium (DMEM; Sigma, USA, Cat. No. 10270-106) supplemented with 10 % foetal bovine serum (FBS; Gibco, Cat. No. 10270-106) and gentamicin (40 μg/ml, LEK, Slovenia). These samples were used for evaluating the size of the cell spreading area (day 1), and for evaluating cell shape and cell viability (days 1, 4 and 7 after seeding). The size o f the cell spreading area was measured using Atlas Software (Tescan Ltd., Brno, Czech Republic). The viability of the cells was determined by the LIVE/DEAD viability cytotoxicity kit for mammalian cells (Invitrogen, Molecular Probes, USA). The larger samples (30x30 mm) were inserted into GAMA polystyrene dishes (diameter 5 cm; GAMA Group Joint- Stock Company, Ceske Budejovice, Czech Republic) and seeded with 300000 cells/dish (approx. 15300 cells/cm 2) suspended in 9 ml of the above mentioned culture medium. These samples were used for evaluating the cell number on days 1, 4 and 7 after seeding, using a Beckman Vi- CELL XR Cell Analyser automatic cell counter. The results indicated that the number of initially adhering cells on day 1 after seeding was significantly lower on the titanium (5320±390 cells/cm2) and on the stainless steel ( 4110±370 cells/cm 2) than on the control polystyrene culture dishes (7740±350 cells/cm2). However, on day 4 after seeding, the cell population density on both metallic materials studied here became significantly higher than on the control polystyrene dishes (75200±2 890 cells/cm2 on Ti and 90870 ±2350 cells/cm2 on steel vs. 56440±1180 cells/cm2 on polystrene). This suggests faster cell proliferation on both metallic materials than on polystyrene. At the same time, the cell number on the stainless steel samples was significantly higher than on the Ti samples. On day 7, the differences in number of adhered cells on both studied metals and on the control polystyrene substrate was on an average similar (from 328780±680 cells/cm2 to 362200 ±760 cells/cm2). The cell viability on all tested materials was almost 100 % in all culture intervals. The morphology of the cells on the studied materials was similar to the morphology of the adhered cells on the control polystyrene dishes, i.e. the cells were mostly flat and polygonal, and the size of their cell spreading areas w as similar on all tested materials. The cells were distributed homogeneously on the entire material surface, and on day 4 they started to form confluent cell layers (FIG. (1). It can be concluded that the tests of biocompatibility confirmed that the titanium and the stainless steel promoted the adhesion and growth of bone - derived cells, and thus these materials are promising for construction of bone implants and for their good integration with the surrounding bone tissue. Further studies on osteogenic cell differentiation, potential immune activation and the response of the bone cells to growth factors, including bone morphogenetic protein, are in progress.
Źródło:
Engineering of Biomaterials; 2011, 14, no. 109-111 spec. iss.; 10-11
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrid carbon layers for medical application
Autorzy:
Nowak, D.
Niedzielski, P.
Powiązania:
https://bibliotekanauki.pl/articles/285091.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
hybrid carbon layer
corrosion resistance of stainless steel
RF PACVD methods
Opis:
Carbon layers thanks to their advantages (high biocompatibility, good wear resistance, high corrosion resistance) found the application in medicine. The authors of presented work have obtained improvement of above-mentioned properties (high hardness) with use of hybrid RF PACVD method. Carburizing of the AISI 316L stainless steel is connected with risk of decrease of corrosion resistance which is caused by Cr23C6 formation on the grain boundaries. In the presented work corrosion parameters of the modified elements was investigated. The substrate material used in this work was AISI 316L stainless steel. The hybrid process was performed by RF PACVD method and consisted in carburizing of the sample at the beginning and afterwards carbon film synthesis. The corrosion resistance investigation was conducted using saline solution at similar to human body temperature (37oC), the duration of the investigation was two weeks. Corrosion investigation of modified elements proved that suitable choice of carburizing parameters during the hybrid process doesn’t cause lowering of corrosion resistance of AISI 316L steel. Moreover microscope observations of the modified materials’ structures didn’t show any track of carbide disengagements on the grain boundaries.
Źródło:
Engineering of Biomaterials; 2008, 11, 76; 20-23
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie własności fizykochemicznych bezcementowych panewek stawu biodrowego
Electrochemical study of uncemented hip endoprosthesis cups
Autorzy:
Kajzer, W.
Kajzer, A.
Grzeszczuk, O.
Semenowicz, J.
Mroczka, A.
Powiązania:
https://bibliotekanauki.pl/articles/284760.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stal Cr-Ni-Mo
panewka stawu biodrowego
odporność korozyjna
stainless steel
hip endoprosthesis
corrosion resistance
Opis:
Celem prowadzonych badań było porównanie własności panewki nowej oraz po alloplastyce rewizyjnej przebywającej w organizmie człowieka przez 68 miesięcy. W ramach badań przeprowadzono analizę składu chemicznego, własności mechanicznych oraz fizykochemicznych. Własności te analizowano na podstawie badań z wykorzystaniem optycznej spektrometrii emisyjnej ze wzbudzeniem jarzeniowym, pomiarów twardości oraz badań potencjodynamicznych odporności na korozję wżerową i elektrochemicznej spektroskopii impedancyjnej EIS. Badanie elektrochemiczne przeprowadzono w roztworze Ringera. Dodatkowo przeprowadzono analizę makroskopową powierzchni. Na podstawie przeprowadzonych badań stwierdzono, że badane panewki zostały wytworzone ze stali Cr-Ni-Mo spełniającej zalecenia normy ISO 5832-9. Wyniki pomiarów twardości ujawniły obszary o zróżnicowanym umocnieniu biomateriału panewki. Uzyskane parametry odporności korozyjnej dla panewki po implantacji były porównywalne do wartości uzyskanych dla panewki w stanie wyjściowym. Dodatkowo przeprowadzone badania EIS określiły charakter warstwy tlenkowej występującej na powierzchni implantu po usunięciu z organizmu. Wykazały one występowanie warstwy podwójnej stanowiące dobre zabezpieczenie biomateriału metalowego przed rozwojem niekorzystnych zjawisk korozyjnych. Natomiast przeprowadzone obserwacje makroskopowe ujawniły występowanie warstwy hydroksyapatytu na powierzchni panewki po 68-miesięcznym przebywaniu w organizmie. Podsumowując można stwierdzić, że przyczyną alloplastyki rewizyjnej był brak osteointegracji powierzchni zewnętrznej implantu spowodowany nierównomiernym przyleganiem implantu do powierzchni kości. Nie zaobserwowano jednak zmniejszenia odporności korozyjnej panewki po implantacji, co wskazuje na jej biokompatybilność w środowisku tkankowym.
The aim of the research was to compare the properties of the new cup and the cup after alloplastic revision surgery which has been staying in the human body for 68 months. In the studies chemical composition, mechanical and physicochemical properties were analyzed. The properties were analyzed on the basis of studies of glow discharge atomic emission, measurements of hardness and potentiodynamic studies of resistance to pitting corrosion and electrochemical impedance spectroscopy (EIS). The electrochemical research was conducted in Ringer’s solution. Additionally, analysis of the macroscopic surface was conducted. The results revealed that the cups were produced from high nitrogen stainless steel which chemical composition and mechanical properties met the requirements of the ISO 5832-9 standards. The results of hardness revealed areas with varied strengthening of the cup’s biomaterial. Parameters of the corrosion resistance for the cup after implantation were comparable to the values obtained for the cup in the initial state. Additionally, EIS study determined the nature of the oxide layer on the surface of the implant removed from the body. The results showed the existence of a double layer forming good protection of the metal biomaterial against corrosion. The performed macroscopic observation revealed the presence of hydroxyapatite on the surface of the cup after the 68 months in the body. We conclude that the reason for revision arthroplasty was the lack of osteointegration of the outer surface of the implant caused by non- -uniform adhesion of the implant to the bone surface. However, no reduction in corrosion resistance of the cup after implantation was observed which indicates its biocompatibility in the tissue environment.
Źródło:
Engineering of Biomaterials; 2015, 18, 132; 9-16
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testy potencjodynamiczne drutów stalowych przeznaczonych dla kardiologii
Potentiodynamic tests of steel wires for cardiology
Autorzy:
Przondziono, J.
Walke, W.
Filipek, M.
Wrona, P.
Powiązania:
https://bibliotekanauki.pl/articles/284051.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
druty ze stali nierdzewnej X2CrNiMo 17-12-2
korozja elektrochemiczna
testy potencjodynamiczne w sztucznym osoczu
modyfikacja powierzchni
wires made of stainless steel X2CrNiMo 17-12-2
electrochemical corrosion
potentiodynamic tests in artificial blood plasma
surface modification
Opis:
Celem pracy była ocena wpływu modyfikacji powierzchni oraz odkształcenia zadawanego w procesie ciągnienia na właściwości korozyjne drutów ze stali X2CrNiMo 17-12-2 przeznaczonych dla kardiologii inwazyjnej. Odporność na korozję elektrochemiczną oceniano w oparciu o rejestrację krzywych polaryzacji anodowej metodą potencjodynamiczną. Krótkotrwałe testy potencjodynamiczne, jak również testy po 30. dniowej ekspozycji realizowano w sztucznym osoczu symulującym środowisko układu krwionośnego. Kolejne etapy modyfikacji powierzchni polegały na szlifowaniu drutów po technologicznym procesie ciągnienia, ich elektrochemicznym polerowaniu oraz chemicznej pasywacji. Testy potencjodynamiczne w roztworze sztucznego osocza wykazały zróżnicowaną odporność na korozję elektrochemiczną drutów ciągnionych z odkształceniem w zakresie £=0+2,99. Stwierdzono, że najwyższą odpornością korozyjną charakteryzuje się walcówka w stanie wyżarzonym. Wraz ze wzrostem odkształcenia następuje obniżenie charakterystyk korozyjnych drutu. Zaobserwowano, że z kolei zabiegi modyfikacji powierzchni poprawiają właściwości korozyjne drutów. Dodatkowe polepszenie odporności drutów na korozję elektrochemiczną spowodowała 30. dniowa ekspozycja w sztucznym osoczu.
The study was aimed at evaluation of the impact of surface modification and strain applied in drawing process on corrosion characteristics of wires made of X2CrNiMo 17-12-2 steel used in invasive cardiology. Resistance to electrochemical corrosion was evaluated on the ground of anodic polarisation curves registered by means of potentiodynamic method. Short-term potentiodynamic tests as well as tests after 30-day exposure were performed in artificial blood plasma simulating blood vascular system. Further steps of surface modification comprised grinding wires that have been subject to technological drawing process, their electrochemical polishing and chemical passivation. Potentiodynamnic tests in artificial blood plasma solution showed differentiated resistance to electrochemical corrosion of wires drawn with strain applied within the range of £=0+2,99. It was proved that annealed wire rod featured the highest corrosion resistance. With increasing strain, wire corrosion properties decrease. Next, it was observed that surface treatment increases wire corrosion characteristics. Additional improvement of wire resistance to electrochemical corrosion was brought forth by 30-day exposure to artificial blood plasma.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 104-108
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies