Tytuł:
Harmonic compensation using the sliding DFT algorithm for three-phase active power filter
Autorzy:
Sozański, K. P.
Powiązania:
https://bibliotekanauki.pl/articles/262743.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
active filters
harmonics
DSP
power quality
power factor correction
Opis:
This paper describes the sliding discrete Fourier transform (DFT) algorithm as an alternative for typical DFT used for spectrum analysis and synthesis. As an example a control circuit for a three-phase 75 kVA parallel active power filter (APF) is used. Such filters have been built and tested. Some illustrative, experimental results are also presented in the paper. The control algorithms of the proposed APF are implemented in the fixed-point digital signal processor TMS320C50. The presented control APF algorithm is a good alternative to classical APF control algorithms, because it allows easy selection of control parameters in mains currents: imbalance, reactive power or harmonics contents. In the proposed circuit transient performance of APF is improved using non-causal predictive current compensation.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 15-20
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power quality enhancement of three-phase front-end rectifier of UPS system using current injection technique
Autorzy:
Dhomane, G. A.
Suryawanshi, H.
Powiązania:
https://bibliotekanauki.pl/articles/262756.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
high frequency current injection
high power factor
soft transition
power factor correction circuit
Opis:
Power Quality, in terms of power factor and harmonics, is greatly hampered by a three-phase rectifier used as a front-end ac-to-dc converter in many systems including a UPS. This paper presents the high power factor operation of the converter with reduced total harmonic distortion up to 4%. The power quality up gradation is due to high-frequency current injection, at the input of the front-end rectifier. A small filter is required at the output for filtering the high-frequency content. Sinusoidal PWM technique is used for controlling the output voltage. DSP is used for generating the desired gate pulses. The converter has high efficiency, low EMI emissions, high power packing density and suitable for UPS system. A Simulation and experimentation is carried out on a 3 kW converter and experimental results are in good agreement with simulation results.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2008, 14, 2; 35-39
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies