Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Łaskawiec, E." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/387996.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
integrated process
washings nanofiltration
coagulation
sedimentation
swimming pool water
Installation
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
Opis:
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5–3.0 mgAl/dm3 and sedimentation where the scope of duration 0.5–24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. DK GE Osmonics membrane was used as a nanofiltration membrane. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mgAl/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after coagulation with dose 3.0 mgAl/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
W pracy przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu koagulacji–sedymentacji–nanofiltracji do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5–3,0 mgAl/dm3) oraz sedymentacji (czas trwania 0,5–24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mgAl/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Obecność cząsteczek osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, w której zastosowano wyższą dawkę koagulantu (3,0 mgAl/dm3), równocześnie spowodowała stopniowy wzrost zdolności separacyjnych membrany – utworzyła się tzw. membrana wtórna charakteryzująca się mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 227-236
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the possibility of recycling backwashing water from the swimming pool water treatment system
Ocena możliwości recyklingu popłuczyn z systemu oczyszczania wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/388489.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
swimming pool water
backwashing
toxicological assessment
physicochemical analysis
biotests
wody basenowe
popłuczyny
ocena toksykologiczna
analiza fizykochemiczna
biotest
Opis:
The paper presents the physicochemical analysis and toxicological assessment of backwashing samples taken after the process of washing filter beds in a raw condition after the process of their aeration and dechlorination. The backwash water under investigation originated from circulation systems existing in two indoor swimming pool facilities. The backwash water, as used at the preliminary and the main stages, was characterized by different physicochemical properties. For toxicological assessment, the Mictorox® bioluminescence inhibition test, the Chaoborus sp. insect larva survival test and the phyto test using Lemna minor fine cilium were involved. The investigation presented in the paper included a preliminary phase focusing on the ecotoxic characterization of backwash water subjected to aeration and dechlorination processes. In turn, at the main stage, the effect of aeration duration on the quality of backwash water in terms of its physicochemical parameters was analyzed. The results of the preliminary stage investigation indicate that backwash water, both in a raw condition and after 30 minutes’ aeration, could not be discharged directly to the environment due to the threat to living organisms caused by its high toxicity. Whereas, using 160 minutes’ aeration duration contributed to a significant improvement in the quality of the backwash water and elimination of its toxic properties with respect to the indicator organisms used. The chemical dechlorination process brought about varying effects. In the case of the Microtox® test, a stimulation of bacterial bioluminescence was noted, but, at the same time, the death of individual insect larva specimens was observed. In spite of the high biomass increase in the Lemna minor test, a gradual discolouration of fronds under the influence of backwash water was observed. Because of the presence of numerous compounds being disinfection by-products, as well as coagulant residues in backwash water deriving from swimming pool systems, it is necessary to seek further solutions that will allow them to be recycled, which will result in a reduction of water consumption and effluent discharges.
W pracy przedstawiono analizę fizykochemiczną oraz ocenę toksykologiczną próbek popłuczyn pobranych po procesie płukania złóż filtracyjnych w stanie surowym po procesie napowietrzania oraz dechloracji. Badane popłuczyny pochodziły z obiegów zlokalizowanych w dwóch obiektach basenowych krytych. Do oceny toksykologicznej włączono test inhibicji bioluminescencji Mictorox®, przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania obejmowały fazę wstępną, skupiającą się na charakterystyce ekotoksykologicznej popłuczyn poddanych procesom dechloracji oraz napowietrzania. W etapie zasadniczym badań analizowano dodatkowo wpływ czasu napowietrzania na jakość popłuczyn pod względem parametrów fizykochemicznych. Wyniki wstępnego etapu badań sygnalizuj ą, że popłuczyny zarówno w stanie surowym, jak i po 30-minutowym napowietrzaniu nie mogły zostać bezpośrednio odprowadzone do środowiska ze względu na zagrożenie dla organizmów żywych, spowodowane ich wysoką toksycznością. Natomiast zastosowane wydłużenie czasu napowietrzania (160 min) przyczyni ło się do znaczącej poprawy jakości popłuczyn i pozbawienia ich właściwości toksycznych w stosunku do wykorzystanych organizmów wskaźnikowych. Zróżnicowane efekty przyniósł zabieg chemicznej dechloracji. W przypadku testu Microtox® odnotowano stymulację bioluminescencji bakterii, równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem użytych popłuczyn. Niezbędne jest poszukiwanie dalszych rozwiązań umożliwiających ich recykling, co zapewni ograniczenie zużycia wody oraz odprowadzania ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 4; 401-410
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies