Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "meat industry" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
The application of UASB reactor in meat industry wastewater treatment
Zastosowanie reaktora UASB do oczyszczania ścieków z zakładów mięsnych
Autorzy:
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Mielczarek, K.
Krzywicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/395840.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków z zakładów mięsnych
reaktor UASB
biogaz
meat industry wastewater
reactor UASB
hydraulic retention time
biogas
Opis:
The meat industry is a branch of the food sector, which significantly affects the degradation of the environment. Consuming large amounts of water consequently produces significant quantities of water which are characterised by a high organic content and high concentration of suspended solids, inorganic salts and nutrients. The study attempted to determine the influence of the HRT and OLR on biogas production and the treatment of wastewater from the meat industry, and it was found that the most preferred treatment process carried out was at HRT 3d (OLR-0.55 kgCOD/m3d). The anaerobic process under HRT 3d obtained a considerable degree of the removal of organic pollutants from raw wastewater designated as COD (79%), BOD (77%) and TOC (73%). The concentrations of COD and BOD were 350 mg/dm3 and 363 mg/dm3 respectively. The value of TOC reached a level of 142 mg/dm3. Due to its poor quality, effluent from a UASB reactor cannot be discharged into natural water without additional treatment processes. The addition of reverse osmosis in the meat industry wastewater treatment is suggested.
W badaniach podjęto próbę określenie wpływu czasu zatrzymania ścieków z zakładu mięsnego w reaktorze UASB na efektywność ich oczyszczania oraz na wielkość dobowej produkcji biogazu. HRT zmieniano w zakresie od 2 do 6 dób co wiązało się ze zmianą obciążenia komory ładunkiem zanieczyszczeń z 0,27 kgChZT/m3d do 0,82 kgChZT/m3d. Stwierdzono, że wraz ze skracaniem czasu zatrzymania z 6d do 2d, jakość ścieków ulega pogorszeniu, ale ilość produkowanego biogazu zwiększała się. Zaobserwowano, że wielkość współczynnika biogazu ulegała obniżeniu. Stwierdzono, że najkorzystniej prowadzić proces oczyszczania badanych ścieków przy HRT równym 3 doby z uwagi na dobre efekty oczyszczania i wysoki współczynnik produkcji biogazu wynoszący 0,45 dm3 biogazu/gChZT_us. Prowadzenie procesu fermentacji przy tak ustalonych warunkach pozwoliło na wysoki stopień usunięcia zanieczyszczeń oznaczanych, jako ChZT (79%), BZT5 (77%) i OWO (73%). Stężenie ChZT ścieków oczyszczonych wynosiło 350 mg/dm3, BZT5 463mg/dm3 a OWO 142 mg/dm3. Pomimo wysokiego stopnia usunięcia zanieczyszczeń z badanych ścieków nie ma jednak możliwości odprowadzenia ich do odbiornika naturalnego. Proponuje się, aby w kolejnych etapach badań podjąć próbę doczyszczania ścieków w procesie odwróconej osmozy co w przyszłości może pozwolić na zamknięcie obiegu wody na terenie zakładu.
Źródło:
Civil and Environmental Engineering Reports; 2011, 7; 119-128
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of meat industry wastewater using coagulation and Fentons reagent
Oczyszczanie ścieków zakładów mięsnych w procesie koagulacji i z zastosowaniem odczynnika Fentona
Autorzy:
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Mielczarek, K.
Krzywicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/395853.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
koagulacja
odczynnik Fentona
zakłady mięsne
meat industry wastewater
coagulation process
Fenton process
PIX 113
PAX XL 19
Opis:
The aim of the paper was to study meat industry wastewater treatment efficiency during chemical processes. The research was carried out in two steps. The first step was the coagulation process and the second step was the Fenton reaction. It was found that wastewater treatment with the use of Fenton's reagent achieved a higher degree of removal of the pollutants determined as COD, TOC and TN in comparison to the coagulation of PIX 113. The most profitable dose of the Fenton's reagent was 0.6/1.8 Fe2+/H2O2 g/dm3. The degree of COD removal from the wastewater with the use of the Fenton's reagent was higher by 10% on average compared to PIX 113. TOC and TN removal efficiency, using the Fenton's reagent was higher by 13% and 40.5% respectively when compared to the coagulation process. The aim of the paper was to study meat industry wastewater treatment efficiency during chemical processes. The research was carried out in two steps. The first step was the coagulation process and the second step was the Fenton reaction. It was found that wastewater treatment with the use of Fenton's reagent achieved a higher degree of removal of the pollutants determined as COD, TOC and TN in comparison to the coagulation of PIX 113. The most profitable dose of the Fenton's reagent was 0.6/1.8 Fe2+/H2O2 g/dm3. The degree of COD removal from the wastewater with the use of the Fenton's reagent was higher by 10% on average compared to PIX 113. TOC and TN removal efficiency, using the Fenton's reagent was higher by 13% and 40.5% respectively when compared to the coagulation process.
W badaniach porównano efektywności oczyszczania ścieków powstających podczas uboju i przetwórstwa mięsa w procesie koagulacji oraz w procesie utleniania z zastosowaniem odczynnika Fentona. W procesie koagulacji wykorzystano dwa rodzaje koagulantów (PIX 113 i PAX XL 19). Stwierdzono, że stopień usunięcia ChZT przy użyciu PIX 113 był średnio o 9% wyższy w porównaniu do PAX XL 19. Stosując wyznaczoną jako najkorzystniejszą dawkę PIX 113 wynoszącą 0,6 g/dm3 ścieki po procesie koagulacji charakteryzowały się wartością ChZT, OWO i CA odpowiednio na poziomie 836 mg/dm3, 363 mg/dm3 i 359 mg/dm3. Porównując efektywność usunięcia zanieczyszczeń z oczyszczanych ścieków stwierdzono, że korzystniej prowadzić chemiczny proces ich oczyszczania z zastosowanie odczynnika Fentona. Jako najkorzystniejszą dawkę odczynnika Fentona wyznaczono 0,6/1,8 Fe2+/H2O2 g/dm3. Wartość ChZT ścieków oczyszczonych na drodze koagulacji oraz z zastosowaniem odczynnika Fentona wynosiła odpowiednio 515 mg/dm3 i 834 mg/dm3. Stopień usunięcia OWO ze ścieków z zastosowaniem odczynnika Fentona był średnio o 13% wyższy w porównaniu do procesu koagulacji. Stężenie OWO ścieków oczyszczonych w przypadku reakcji Fentona było na poziomie 241,4 mg/dm3 a po procesie koagulacji 363 mg/dm3. Przeprowadzone badania pokazały również, że pomimo wysokiego stopnia usunięcia zanieczyszczeń ścieki oczyszczone w obu procesach chemicznych nie mogą być odprowadzone do odbiornika naturalnego. Po obu procesach wartość ChZT ścieków oczyszczonych była prawie 7-krotnie (proces koagulacji) i 4- krotnie (reakcja Fentona) przekroczona w stosunku do dopuszczalnych wartości. Wartość OWO po procesie koagulacji i Fentona została przekroczona odpowiednio 12 i 8-krotnie. Prawie 5-krotnie (odczynnik Fentona) i 12-krotnie (proces koagulacji) w ściekach oczyszczonych została przekroczona wartość azotu całkowitego. Z uwagi na to sugeruje się łączenie tych procesów z innym procesami jednostkowymi np. procesem biologicznym lub ciśnieniowymi technikami membranowymi.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 45-58
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies