Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "kondensacja" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Studies on the process of recovering low-temperature waste heat from a flue gas in a pilot-scale plant
Autorzy:
Szulc, P.
Tietze, T.
Wójs, K.
Powiązania:
https://bibliotekanauki.pl/articles/185836.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat recovery
condensation
inert gas
odzysk ciepła
kondensacja
gaz obojętny
Opis:
This paper presents studies carried out in a pilot-scale plant for recovery of waste heat from a flue gas which has been built in a lignite-fired power plant. The purpose of the studies was to check the operation of the heat recovery system in a pilot scale, while the purpose of the plant was recovery of waste heat from the flue gas in the form of hot water with a temperature of approx. 90 °C. The main part of the test rig was a condensing heat exchanger designed and built on the basis of laboratory tests conducted by the authors of this paper. Tests conducted on the pilot-scale plant concerned the thermal and flow parameters of the condensing heat exchanger as well as the impact of the volumetric flow rate of the flue gas and the cooling water on the heat flux recovered. Results show that the system with a condensing heat exchanger for recovery of low-temperature waste heat from the flue gas enables the recovery of much higher heat flux as compared with conventional systems without a condensing heat exchanger.
Źródło:
Chemical and Process Engineering; 2016, 37, 4; 529-543
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer in helical coil heat exchanger:An experimental parametric study
Autorzy:
Kowalski, Krzysztof
Downarowicz, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/185443.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
helical coil
heat exchanger
condensation
Wilson method
laminar flow
pressure drop
wymiennik ciepła
kondensacja
Metoda Wilsona
przepływ laminarny
Spadek ciśnienia
Opis:
Helical coil heat exchangers are widely used in a variety of industry applications such as refrigerationsystems, process plants and heat recovery. In this study, the effect of Reynolds number and theoperating temperature on heat transfer coefficients and pressure drop for laminar flow conditions wasinvestigated. Experiments were carried out in a shell and tube heat exchanger with a copper coiledpipe (4 mm ID, length of 1.7 m and coil pitch of 7.5 mm) in the temperature range from 243 to 273 K.Air – propan-2-ol vapor mixture and coolant (methylsilicone oil) flowed inside and around the coil,respectively. The fluid flow in the shell-side was kept constant, while in the coil it was varied from 6.6to 26.6 m/s (the Reynolds number below the critical value of 7600). Results showed that the helicalpipe provided higher heat transfer performance than a straight pipe with the same dimensions. Theconvective coefficients were determined using the Wilson method. The values for the coiled pipe werein the range of 3–40 W/m2·K. They increased with increasing the gas flow rate and decreasing thecoolant temperature.
Źródło:
Chemical and Process Engineering; 2019, 40, 1; 101--114
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies