Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "energy balance" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Energy Balance Sheet of a Semi Operational Thermic System
Autorzy:
Honus, S.
Sassmanová, V.
Frantík, J.
Bukowski, P.
Juchelková, D.
Powiązania:
https://bibliotekanauki.pl/articles/185341.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bilans energetyczny
piroliza
odpady
spalanie
gaz procesowy
energy balance
pyrolysis
waste
combustion
process gas
Opis:
The article is focused onthe energetical balance of a technical system for the conversion of crushed tyres by pyrolysis. Process temperatures were set in the range from 500 to 650°C. Mass input of the material was 30 kg per hour. The aim of the article is to answer the following questions as regards the individual products: Under which process conditions can the highest quality of the individual products related to energy be reached? How does the thermal efficiency of the system change in reaction to various conditions of the process? On the basis of the experimental measurements and calculations, apart from other things, it was discovered that the pyrolysis liquid reaches the highest energetic value, i.e. 42.7 MJ.kg-1, out of all the individual products of the pyrolysis process. Generated pyrolysis gas disposes of the highest lower calorific value 37.1 MJ.kg-1 and the pyrolysis coke disposes of the maximum 30.9 MJ kg-1. From the energetic balance, the thermal efficiency of the experimental unit under the stated operational modes ranging from about 52 % to 56 % has been estimated. Individual findings are elaborated on detail in the article.
Źródło:
Chemical and Process Engineering; 2014, 35, 3; 317-329
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of operation problems at a 200 MWe PF boiler
Autorzy:
Peta, S.
Toit, C. du
Naidoo, R.
Schmitz, W.
Jestin, L.
Powiązania:
https://bibliotekanauki.pl/articles/185774.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
process flow modeling
mass and energy balance
furnace CFD modeling
PF swirl burner
proces modelowania przepływu
bilans masy i energii
modelowanie pieca CFD
Opis:
To minimize oxides of nitrogen (NOx) emission, maximize boiler combustion efficiency, achieve safe and reliable burner combustion, it is crucial to master global boiler and at-the-burner control of fuel and air flows. Non-uniform pulverized fuel (PF) and air flows to burners reduce flame stability and pose risk to boiler safety by risk of reverse flue gas and fuel flow into burners. This paper presents integrated techniques implemented at pilot ESKOM power plants for the determination of global boiler air/flue gas distribution, wind-box air distribution and measures for making uniform the flow being delivered to burners within a wind-box system. This is achieved by Process Flow Modelling, at-the-burner static pressure measurements and CFD characterization. Global boiler mass and energy balances combined with validated site measurements are used in an integrated approach to calculate the total (stoichiometric + excess) air mass flow rate required to burn the coal quality being fired, determine the actual quantity of air that flows through the burners and the furnace ingress air. CFD analysis and use of at-the-burner static, total pressure and temperature measurements are utilized in a 2-pronged approach to determine root-causes for burner fires and to evaluate secondary air distribution between burners.
Źródło:
Chemical and Process Engineering; 2015, 36, 3; 305-320
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of heat transfer in combustion chamber waterwall tubes of supercritical steam boilers
Autorzy:
Grądziel, S.
Majewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/185848.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
waterwall tube
supercritical steam boiler
mathematical model
energy balance
thermal load
rura ekranowa
kocioł parowy
model matematyczny
balans energetyczny
obciążenie cieplne
Opis:
The paper presents the results of numerical computations performed for the furnace chamber waterwalls of a supercritical boiler with a steam output of 2400 x 10[3] kg/h. A model of distributed parameters is proposed for the waterwall operation simulation. It is based on the solution of equations describing the mass, momentum and energy conservation laws. The aim of the calculations was to determine the distribution of enthalpy, mass flow and fluid pressure in tubes. The balance equations can be brought to a form where on the left-hand side space derivatives, and on the right-hand side – time derivatives are obtained. The time derivatives on the right-hand side were replaced with backward difference quotients. This system of ordinary differential equations was solved using the Runge-Kutta method. The calculation also takes account of the variable thermal load of the chamber along its height. This thermal load distribution is known from the calculations of the heat exchange in the combustion chamber. The calculations were carried out with the zone method.
Źródło:
Chemical and Process Engineering; 2016, 37, 2; 199-213
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies