Wyświetlanie 1-2 z 2
Tytuł:
Multichannel ultrasonic range finder for blind people navigation
Autorzy:
Gelmuda, W.
Kos, A.
Powiązania:
https://bibliotekanauki.pl/articles/202400.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multichannel ultrasonic range finder
blind people navigation
Opis:
The purpose of this paper is to present a multichannel ultrasonic range finder which was designed for the navigation system for blind people. A substantial number of consultations with blind people in the Blind People Centre in Krakow have shown that the navigation and obstacle detection with a help of a white stick only, is not sufficient enough to assure a high safety level. Electronic aids which are being designed for blind people should be mobile, comfortable and low-powered. That is why the MOBIAN© (a mobile safety system for the blind) project is being carried out by the authors to create a highly reliable safety navigation system for blind people. It could not only improve blind people quality of life but also their safety, especially when they are walking in unknown areas. As a part of this project, the multichannel ultrasonic range finder was designed, produced and tested. The tests have proven the device is capable of detecting objects from different directions in a range over 4 m. The device interface is easy to manage and can be controlled by almost any microcontroller or FPGA chip. The designed range finder is to be implemented in the electronic assistant project for blind people. Other systems, including the industrial ones, for instance, mobile robots or gates that count people entries, could benefit from this multichannel range finder. Usually, some low-cost ultrasonic range finders use two transducers for each channel (a transmitter and a receiver). The designed device employs only one transducer per channel which minimizes the end-device size and cost and at the same time provides with the main functionality. Novelty of this device is its multichannel design and the emplacement of the ultrasonic transducers, which can be used due to the application of the multichannel analog multiplexer. Thus, it is possible to detect obstacles, even the inclined ones, with higher reliability and increase the safety of blind people while walking. Also, this design and the transducers’ placement allow to detect obstacles much quicker, when the blind user suddenly turns.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 3; 633-637
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low-power low-area techniques for multichannel recording circuits dedicated to biomedical experiments
Autorzy:
Kmon, P.
Powiązania:
https://bibliotekanauki.pl/articles/201066.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomedical experiments
noise
multichannel integrated circuits
eksperymenty biomedyczne
hałas
wielokanałowe zintegrowane obwody
Opis:
This paper presents techniques introduced to minimize both power and silicon area of the multichannel integrated recording circuits dedicated to biomedical experiments. The proposed methods were employed in multichannel integrated circuit fabricated in CMOS 180nm process and were validated with the use of a wide range of measurements. The results show that both a single recording channel and correction blocks occupy about 0.061 mm2 of the area and consume only 8.5 μW of power. The input referred noise is equal to 4.6 μVRMS. With the use of additional digital circuitry, each of the recording channels may be independently configured. The lower cut-off frequency may be set within the range of 0.1 Hz–700 Hz, while the upper cut-off frequency, depending on the recording mode chosen, can be set either to 3 kHz/13 kHz or may be tuned in the 2 Hz–400 Hz range. The described methods were introduced in the 64-channel integrated circuit. The key aspect of the proposed design is the fact that proposed techniques do not limit functionality of the system and do not deteriorate its overall parameters.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 3; 615-624
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies