Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "electromagnetic energy" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Energy balance in self-powered MR damper-based vibration reduction system
Autorzy:
Snamina, J.
Sapiński, B.
Powiązania:
https://bibliotekanauki.pl/articles/202332.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
MR damper
electromagnetic generator
vibration
energy balance
Opis:
The study is focused on the energy balance in self-powered vibration reduction system with a linear magnetorheological (MR) damper. The mathematical model of the vibration reduction system is outlined and numerical simulation data are provided. The model involves the mechanical and electrical sub-systems of the electromagnetic generator and an MR damper. For the purpose of the numerical simulations, the parameters of the model were identified through experiments. The objective of the simulations was to establish the energy balance of the system. Energy fluxes associated with energy inputs and outputs as well as a rate of change of inertial energy were determined.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 1; 75-80
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and investigations of inductive power transfer (IPT) systems in terms of efficiency and magnetic field distribution properties
Autorzy:
Miśkiewicz, R. M.
Anczewski, P.
Moradewicz, A. J.
Powiązania:
https://bibliotekanauki.pl/articles/202253.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
contactless energy transfer
inductive power transfer
resonant compensation circuits
electromagnetic field distribution
Opis:
The problems connected to developing inductive power transfer IPT systems in aspects of high efficiency and suppression of electromagnetic field (EMF) emission are discussed. It is shown how important it is to compensate for large leakage impedance of IPT coils (air transformer) to improve efficiency of high power transfer. Such compensation circuits operating with resonant frequencies at soft switching conditions additionally allow for reduction of switching losses in power semiconductor devices of converters. The consideration has been illustrated and verified by experimental results measured on two different test stands (50 kW with planar coils and with two 12 kW receiver coils) built in a laboratory of the Łukasiewicz Research Network – Electrotechnical Institute.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 4; 789-797
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power losses and energy efficiency analysis of HPS lamps with electromagnetic control gear and electronic ballast under the sinusoidal and nonsinusoidal condition
Autorzy:
Sikora, Roman
Markiewicz, Przemysław
Rózga, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2173621.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
HPS lamps
electromagnetic control gear
electronic ballast
energy performance indicator
road lighting
lampa HPS
układ sterowania elektromagnetyczny
balast elektroniczny
wskaźnik wydajności energetycznej
oświetlenie drogowe
Opis:
Outdoor lighting is an important element in creating an evening and nocturnal image of urban spaces. Properly designed and constructed lighting installations provide residents with comfort and security. One way to improve the energy efficiency of road lighting installation is to replace the electromagnetic control gear (ECG) with electronic ballasts (EB). The main purpose of this article is to provide an in-depth comparative analysis of the energy efficiency and performance of HPS lamps with ECG and EB. It will compare their performance under sinusoidal and nonsinusoidal voltage supply conditions for the four most commonly used HPS lamps of 70 W, 100 W, 150 W, and 250 W. The number of luminaires supplied from one circuit was determined based on the value of permissible active power losses. With the use of the DIALux program, projects of road lighting installation were developed. On this basis, energy performance indicators, electricity consumption, electricity costs, and CO 2 emissions were calculated for one-phase and three-phase installations. The obtained results indicate that an HPS lamp with EB is better than an HPS lamp with ECG in terms of energy quality, energy savings, and environmental impact. The results of this analysis are expected to assist in the choice of HPS lighting technology.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; art. no. e137194
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power losses and energy efficiency analysis of HPS lamps with electromagnetic control gear and electronic ballast under the sinusoidal and nonsinusoidal condition
Autorzy:
Sikora, Roman
Markiewicz, Przemysław
Rózga, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2128159.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
HPS lamps
electromagnetic control gear
electronic ballast
energy performance indicator
road lighting
lampa HPS
układ sterowania elektromagnetyczny
balast elektroniczny
wskaźnik wydajności energetycznej
oświetlenie drogowe
Opis:
Outdoor lighting is an important element in creating an evening and nocturnal image of urban spaces. Properly designed and constructed lighting installations provide residents with comfort and security. One way to improve the energy efficiency of road lighting installation is to replace the electromagnetic control gear (ECG) with electronic ballasts (EB). The main purpose of this article is to provide an in-depth comparative analysis of the energy efficiency and performance of HPS lamps with ECG and EB. It will compare their performance under sinusoidal and nonsinusoidal voltage supply conditions for the four most commonly used HPS lamps of 70 W, 100 W, 150 W, and 250 W. The number of luminaires supplied from one circuit was determined based on the value of permissible active power losses. With the use of the DIALux program, projects of road lighting installation were developed. On this basis, energy performance indicators, electricity consumption, electricity costs, and CO 2 emissions were calculated for one-phase and three-phase installations. The obtained results indicate that an HPS lamp with EB is better than an HPS lamp with ECG in terms of energy quality, energy savings, and environmental impact. The results of this analysis are expected to assist in the choice of HPS lighting technology.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; e137194, 1--22
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies