Tytuł:
Sravnitelʹnyj analiz datčikov gazovyh izveŝatelej dlâ rannego obnaruženiâ požara
Comparative Analysis of Sensors Contained in Gas Detectors Designed For Early Fire Detection
Analiza porównawcza czujników wykorzystywanych w czujkach gazu do wczesnego wykrywania pożaru
Autorzy:
Kozubovskiy, V. R.
Misevich, I. Z.
Ivanchuk, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/372872.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire
detector
multisensory
gas
sensor
concentration
electrochemical
electrolytic
oxidic
pożar
czujka
wielosensorowy
dym
gaz
czujnik
stężenie
elektrochemiczny
tlenkowy
elektrolityczny
Opis:
Aim: The purpose of this article is to help designers of fire detectors with the selection of a carbon monoxide (CO) sensor for a multi-sensor fire detector. Academic work on detectors provides an abundance of material about sensors suitable for CO analysis. Each sensor has its advantages and disadvantages. Therefore, choosing a suitable sensor is quite difficult. The authors, based on their extensive experience in the development and production of devices for gas analysis and fire detectors, propose most adequate solutions. Introduction: Current devices for discovering a fire, work on the principle of detecting smoke, often incorporating a temperature sensor. However, these have many disadvantages. They do not function in a discerning way in relation to smoke (aerosols, water vapour, cooking vapour and dust are all identified as smoke). A CO fire detector is free of these shortcomings, since it is selective and reacts to CO. For this reason many perspective European norms and international standards emerged, which recommend CO analysis for detection of fires. Obviously, high concentrations of CO can occur in areas where people smoke, where heating appliances utilising solid and gaseous fuels are used, in garages and in underground car parks. Multi-Sensor Detectors with two methods of detecting fire, CO and smoke, compensate shortcomings of each method. It can be confidently stated that through a simultaneous response from both detection methods, a fire will be dealt with at an early stage of development and resources will not be sidetracked by dust, water vapour, aerosols or high concentration of CO. For detection of CO, existing standards recommend the use of electrochemical sensors. Methods: The article describes the technical parameters of the most appropriate electrochemical sensors for monitoring of CO. These are electrolytic, based on acidic electrolyte and metal oxide semiconductors, namely Nap-508 (505) and TGS2442. The principles of operation and recommended circuit connection are suitably described in the article. The sensors are specially designed for use with gas fire detectors and were tested in accordance with requirements for fire detectors. It is noted that metal-oxide sensors have the most acceptable performance characteristics, across the broadest temperature range, long period of validity and absence of aggressive substances in composite elements. Among its disadvantages is a relatively high power consumption ~ 15 mW. Conclusions: Examined prospects for the development and production of metal oxide semiconductor sensors. It is indicated that the use of micro and nanotechnology in the manufacture of sensors will solve the problem of reducing energy consumption to a level sufficient for the production of self-contained smoke detectors powered by batteries. At present, Figaro has developed a sensor TGS8410 with an average power consumption of 0.087 mW.Aim: The purpose of this article is to help designers of fire detectors with the selection of a carbon monoxide (CO) sensor for a multi-sensor fire detector. Academic work on detectors provides an abundance of material about sensors suitable for CO analysis. Each sensor has its advantages and disadvantages. Therefore, choosing a suitable sensor is quite difficult. The authors, based on their extensive experience in the development and production of devices for gas analysis and fire detectors, propose most adequate solutions. Introduction: Current devices for discovering a fire, work on the principle of detecting smoke, often incorporating a temperature sensor. However, these have many disadvantages. They do not function in a discerning way in relation to smoke (aerosols, water vapour, cooking vapour and dust are all identified as smoke). A CO fire detector is free of these shortcomings, since it is selective and reacts to CO. For this reason many perspective European norms and international standards emerged, which recommend CO analysis for detection of fires. Obviously, high concentrations of CO can occur in areas where people smoke, where heating appliances utilising solid and gaseous fuels are used, in garages and in underground car parks. Multi-Sensor Detectors with two methods of detecting fire, CO and smoke, compensate shortcomings of each method. It can be confidently stated that through a simultaneous response from both detection methods, a fire will be dealt with at an early stage of development and resources will not be sidetracked by dust, water vapour, aerosols or high concentration of CO. For detection of CO, existing standards recommend the use of electrochemical sensors. Methods: The article describes the technical parameters of the most appropriate electrochemical sensors for monitoring of CO. These are electrolytic, based on acidic electrolyte and metal oxide semiconductors, namely Nap-508 (505) and TGS2442. The principles of operation and recommended circuit connection are suitably described in the article. The sensors are specially designed for use with gas fire detectors and were tested in accordance with requirements for fire detectors. It is noted that metal-oxide sensors have the most acceptable performance characteristics, across the broadest temperature range, long period of validity and absence of aggressive substances in composite elements. Among its disadvantages is a relatively high power consumption ~ 15 mW. Conclusions: Examined prospects for the development and production of metal oxide semiconductor sensors. It is indicated that the use of micro and nanotechnology in the manufacture of sensors will solve the problem of reducing energy consumption to a level sufficient for the production of self-contained smoke detectors powered by batteries. At present, Figaro has developed a sensor TGS8410 with an average power consumption of 0.087 mW.
Cel: Celem artykułu jest udzielenie wskazówek konstruktorom czujek pożarowych odnośnie wyboru czujników tlenku węgla w komorze wielosensorowej czujki pożarowej. W monografiach poświęconych tej tematyce znaleźć można wiele czujników nadających się do analizy CO. Każdy czujnik ma swoje zalety jak i wady. W związku z tym wybór odpowiedniego czujnika jest dość trudny. Autorzy, na bazie wieloletniego doświadczenia w projektowaniu i produkcji przyrządów do analizy gazowej i czujek pożarowych, zaproponowali najbardziej adekwatne rozwiązania. Wprowadzenie: Obecnie do wykrywania pożarów bardzo często wykorzystywane są czujki dymu (zwykle z czujnikiem temperatury). Mają one jednak wiele wad – nie działają w sposób selektywny na dym (rozpoznają jako dym aerozole, parę wodną, parę powstającą przy gotowaniu, kurz). Czujka pożarowa CO nie ma takich wad, ponieważ reaguje wyłącznie na CO. Dlatego powstało wiele perspektywicznych norm europejskich i standardów międzynarodowych, które do wykrywania pożarów przewidują analizę CO. Oczywiście, duże stężenia CO mogą powstać w pomieszczeniach, w których pali się papierosy, również tam gdzie znajdują się urządzenia ciepłownicze na paliwo stałe lub gazowe, w garażach i parkingach podziemnych. Wielosensorowe czujki, wykorzystujące dwie komory wykrywania pożaru – CO i dymu, rekompensują wady każdej z tych komór. Przy jednoczesnej aktywacji obu, można z pewnością stwierdzić, że mamy do czynienia z pożarem we wczesnym stadium rozwoju, a nie z kurzem, parą wodną, aerozolem lub po prostu dużym stężeniem CO. Do wykrywania CO odpowiednie nomy rekomendują użycie czujników elektrochemicznych. Metody: W artykule opisano parametry techniczne najbardziej odpowiednich do kontroli CO czujników elektrochemicznych na bazie elektrolitów kwasowych i półprzewodników tlenkowych, a dokładnie Nap-508 (505) и TGS2442. Opisano również zasady pracy i zalecane schematy połączeń. Czujniki te były opracowywane specjalnie do wykorzystania w pożarniczych czujkach gazu i przeszły wszystkie badania zgodnie z wymogami dla czujek pożarniczych. Zaznaczono, że czujniki tlenkowe mają najbardziej akceptowalne charakterystyki eksploatacyjne – najszerszy zakres temperatur, długi termin ważności, brak w składzie elementów środowiska agresywnego. Do ich wad należy względnie duże zużycie energii ~ 15 mW. Wnioski: Rozpatrzono perspektywy rozwoju technologii produkcji półprzewodnikowych czujników tlenkowych. Wskazano, że zastosowanie mikro- i nanotechnologii przy produkcji tych czujników rozwiązuje kwestię zmniejszenia zużycia energii do poziomu dostatecznego do przygotowania autonomicznych czujek pożarniczych zasilanych baterią. Już teraz firma Figaro opracowała czujkę TGS8410 za średnim zużyciem prądu 0,087 mW.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 4; 107-122
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Povyšenie èffektivnosti raboty sovremennyh točečnyh optičeskih dymovyh izveŝatelej
Improvement in the Operating Effectiveness of Modern Optical Point Smoke Detectors
Zwiększenie skuteczności pracy nowoczesnych optycznych punktowych czujek dymu
Autorzy:
Kitsak, A. I.
Lushchik, A. P.
Yesipovich, D. L.
Kaval'chuk, I. V.
Powiązania:
https://bibliotekanauki.pl/articles/373121.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
optical point smoke detector
linear smoke detector
laser source
smoke
sensitivity
emission
punktowa czujka dymu
liniowa czujka dymu
źródło laserowe
dym
czułość
skupianie promieniowania
Opis:
Aim: Optical point smoke detectors have a number of significant drawbacks. The foremost are: dependence on the sensitivity of average smoke particle size, of different smoke variety, detection of the smoke emission path, dispersed by given particles, and reaction lead time, determined by the speed of convective air flow and design characteristics of the smoke detector chamber. These drawbacks are absent in linear optical smoke detectors, where the reaction to a fire is determined by the control of flow intensity of transmitted rays (non-dispersed) from smoke emissions. The purpose of this research is to improve the optical design of laser smoke detectors by exploiting traditional fire detection methods (intensity level of rays dispersed by smoke particles), and techniques used by linear smoke detectors. Methods: The project aim is realized with the aid of mathematical techniques and experimental modeling of energy transfer processes, by recording light beam expansion in an optically disparate environment, using aerosol smoke. Results: A two-channel laser smoke detector model was produced and tested for effectives. The main focus of tests was on the sensor’s sensitivity threshold. Tests were conducted in a flow through smoke chamber, with transverse dimensions of 500-500 mm2. The optical smoke density in the channel was controlled by a smoke control block. Sawdust was applied to create smoke. The lowest average unit value of optical smoke density during tests revealed a stable deviation for measured signals in both channels of the sensor. During an absence of smoke the value was identified as 0.11 dB/m. The optical smoke density measurements in the testing chamber, for dispersed ray emissions of the test model, revealed a reading of 0.065 dB/m.. Conclusions: Sensitivity research results for the enhanced laser smoke detector confirmed the potential for improving reliability, by increasing the proportion of detected emissions dispersed at small angles. The special structure of the detector light beam allows for the creation of an effective algorithm used for processing of registered signals, thus improving the sensor’s resistance to noise interference.
Cel: Punktowe optyczne czujki dymu, jak wiadomo, mają wiele istotnych wad. Główne z nich to: 1) zależność czułości od średnich rozmiarów cząsteczek różnorodnych dymów i kierunku rejestrowania promieniowania, rozproszonego przez dane cząsteczki; 2) zależność czasu reakcji od prędkości strumieni konwekcyjnych powietrza i właściwości konstrukcyjnych komory dymowej czujki. Wymienione niedoskonałości nie dotyczą liniowych optycznych czujek dymu, których reakcja na rozgorzenie pożaru polega na kontroli intensywności przechodzącego (nierozproszonego) przez dym promieniowania. Celem pracy jest udoskonalenie optycznego schematu laserowej punktowej czujki dymu, pozwalającego na jednoczesne zastosowanie tradycyjnej metody wykrywania pożaru charakterystycznej dla czujek tego typu (stopień intensywności promieniowania rozproszonego przez cząsteczki dymu) oraz metody stosowanej w liniowych czujkach dymu. Projekt i metody: Aby zrealizować ten cel, wykorzystano metodę matematycznego i eksperymentalnego modelowania procesu przenoszenia i rejestrowania wiązek świetlnych poprzez optycznie niejednorodne środowisko typu aerozol dymowy. Wyniki: Przygotowano model punktowej dwukanałowej laserowej czujki dymu, na którym przeprowadzono badanie jej skuteczności. Podstawową badaną cechą modelu czujki była jej czułość progowa. Badania prowadzono w dymowej komorze przepływowej o rozmiarach poprzecznych 500 x 500 mm2. Optyczna gęstość dymu w komorze była kontrolowana przez blok kontroli zadymienia. Do wytworzenia dymu zastosowano trociny. Najmniejsza średnia wartość jednostkowej optycznej gęstości dymu w komorze badawczej, przy której odnotowano stabilne odchylenie wartości sygnałów mierzonych w obu kanałach modelu czujki od ich średnich wartości przy braku dymu, wyniosła 0,11 dB/m. Przy tym optyczna gęstość dymu mierzona w kanale rejestrowania rozproszonego promieniowania modelu czujki wyniosła 0,065 dB/m. Wnioski: Wyniki badania czułości udoskonalonego modelu laserowej dymowej czujki świadczą o możliwości poprawienia jej niezawodności poprzez zwiększenie udziału rejestrowanego promieniowania rozproszonego na małe kąty. Specjalna struktura wiązki świetlnej w czujce pozwala na sformułowanie skutecznego algorytmu przetwarzania rejestrowanych sygnałów w celu poprawy odporności czujki na zakłócenia.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 4; 125-130
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fotele tapicerowane jako źródło zagrożenia pożarowego sal kinowo-widowiskowych
Upholstered Seats in Cinemas and Theatres – Source of Fire Hazard
Autorzy:
Kopański, M. K.
Powiązania:
https://bibliotekanauki.pl/articles/373353.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fotel
PN-EN 1021
kalorymetr meblowy
intensywność wydzielania ciepła
pożar
zabezpieczenie p.poż
termowizja
dym
PN-EN 45545
upholstered seating
EN1021
furniture calorimeter
heat release rate
fire
fire protection
thermal
smoke
EN 45545
Opis:
Cel: Celem publikacji jest ocena zagrożenia pożarowego sal kinowo-widowiskowych wyposażonych w siedziska tapicerowane (fotele) spełniające aktualne wymogi techniczno-prawne. Fotele w salach mieszczących powyżej 200 osób dorosłych lub 100 dzieci bada się przy użyciu źródeł ognia o małej mocy (tlący się papieros, płomień zapałki). Należy ustalić jak zareagują fotele i jaki będzie miał przebieg pożar, gdy zastosujemy inne źródło ognia (np. palącą się złożoną gazetę). Materiał i metody: Badania przeprowadzono na pełnowymiarowych fotelach oraz ich układach tapicerskich, które są ogólnodostępnymi wyrobami handlowymi na rynku europejskim spełniającymi wymagania zapalności mebli tapicerowanych, które są zgodne z metodą EN-PN 1021-1 Ocena zapalności mebli tapicerowanych. Źródło zapłonu: tlący się papieros oraz EN-PN 1021-2 Ocena zapalności mebli tapicerowanych. Źródło zapłonu: równoważnik płomienia zapałki. W celu ustalenia zagrożenia pożarowego siedzisk tapicerowanych od innych źródeł zapłonu, poddano je badaniom według wymagań normy kolejowej PN-EN 45545-2 Aneks B, C, PN-ISO 9705, ISO/TR 9705-2 (kalorymetr meblowy). Dodatkowo wyznaczono profile temperatur na powierzchni podpalanych foteli wykorzystując do tego celu kamerę termowizyjną. Wyniki: Stopień zagrożenia pożarowego w pomieszczeniach wypełnionych fotelami spełniającymi wymagania (PN-EN 1021-1/2) wzrasta w zależności od rodzaju użytego źródła zapłonu. Fotel uważany za bezpieczny i spełniający wymagania zapalności mebli przebadano na kalorymetrze meblowym i uzyskano następujące wyniki: maksymalną intensywność wydzielania ciepła fotel 1 – 10,78 kW, fotel 2 – 356,83 kW; ciepło wydzielone przez fotel 1 – 635,8 kJ oraz fotel 2 – 81605,6 kJ; MAHRE fotel 1 – 1,62 kW, fotel 2 – 204,37 kW, które świadczą o bardzo dużym zagrożeniu pożarowym. W czasie badań laboratoryjnych zaobserwowano bardzo duże zadymienie pomieszczenia, w którym prowadzone były badania. Potwierdziły to wyniki całkowitej ilości wydzielonego dymu: fotel 1 – 5,3 m2, fotel 2 – 750,3 m2, a osłabienie wiązki światła w fotometrze wyniosło prawie 91%. W czasie pożaru fotela nr 2 temperatura jego powierzchni przekroczyła 900°C. Wnioski: Zaleca się modyfikację i rozszerzenie palety źródeł zapłonu w obowiązującej normie. Za wzór można przyjąć angielską normę BS 5852, zgodnie z którą rozpatrywanych jest osiem różnych rodzajów źródeł zapłonu w zależności od rodzaju i przeznaczenia pomieszczenia. Przegląd mebli tapicerowanych pod względem oceny palności wskazuje, że powinny one być przebadane w pełnej skali z uwzględnieniem większych źródeł zapłonu, jak np. kule z gazety lub stosy z drewna.
Aim: The purpose of this paper is to evaluate potential fire hazards in cinemas and theatres, equipped with upholstered furniture, which satisfy prevailing technical requirements. Introduction: Upholstered seating in public places, which accommodate above two hundred adults or one hundred children, are tested in laboratories with the aid of small fire sources (a smouldering cigarette or ignited match). However, it is appropriate to determine the behaviour of upholstery material and potential development of a fire when other fire sources are applied, such as a folded burning newspaper. Materials and methods: The study was conducted on upholstered furniture, which is generally available on the European market and, which satisfies fire safety standards for upholstered furniture in accordance with EN-PN 1021-1. The fire source used for tests was a smouldering cigarette in accordance with EN-PN 1021-2 and the equivalent of a burning match flame. In order to determine the fire hazard of upholstered seating from other ignition sources, research was performed in accordance with test standards; EN 45545-2, Annex B and C, PN-ISO 9705, ISO/TR 9705-2 (Furniture Calorimeter). Additionally, temperature profiles were identified on the surface of ignited armchairs with the aid of thermal cameras. Results: The fire hazard level in premises furnished with upholstered furniture, which satisfy standards (PN-EN1021-1/2), increases, depending on the employed ignition source. Upholstered furniture, which was considered safe and satisfied fire safety standards was further exposed to tests on a furniture calorimeter with following results: The maximum intensity of heat release for armchair 1 = 10.78 kW, armchair 2 = 356.83 kW; total heat release for armchair 1 = 635.8 kJ, armchair 2 = 81605.6 kJ; MAHRE armchair 1 = 1.62 kW, MAHRE armchair 2 = 204.37 kW, which demonstrates a high risk of fire. During laboratory tests a large volume of smoke was observed in the room where research was performed. This is borne out by the total volume of smoke output for armchair 1 = 5.3 m2, armchair 2 = 750.3 m2. and the reduction in intensity of light rays, measured by the light meter, was approaching 91%. During a fire of armchair 2 the surface temperature exceeded 900°C. Conclusions: It is recommended that the range of ignition tests utilised in current standards is modified and extended. United Kingdom (UK) provides such an example with the BS 5852 standard, where eight different sources of ignition are employed, depending on type and use the premises are put to (cinema, hospital, hotel, museum). An examination of upholstered furniture, involving an evaluation of flammability, should be performed within a full range of the most significant sources of ignition, such as balls of newspaper or piles of wood.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 3; 31-42
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies