Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "combined heat and power" wg kryterium: Wszystkie pola


Wyświetlanie 1-6 z 6
Tytuł:
Technical and economical analysis of exploitation of gas fired small scale combined heat and power systems in Poland
Analiza uwarunkowań techniczno-ekonomicznych budowy gazowych układów kogeneracyjnych małej mocy w Polsce
Autorzy:
Skorek, J.
Powiązania:
https://bibliotekanauki.pl/articles/172934.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
układ CHP
układ kogeneracyjny
combined heat and power module
cogeneration system
Opis:
Paper presents an estimation of influence of selected technical and financial parameters on the cost-effectiveness of the small scale cogeneration systems in Poland. The influence of electrical efficiency of the combined heat and power (CHP) module and power-to-heat ratio on the exploitation costs and incomes of the whole cogeneration system has been analysed. Analysis has been carried out on the example of small scale CHP with the reciprocating internal combustion (IC) gas engine or gas turbine fired by natural gas or coal bed methane.
Przeprowadzono ocenę wpływu wybranych parametrów technicznych, eksploatacyjnych i cenowych na wskaźniki opłacalności budowy gazowych układów kogeneracyjnych małej mocy w Polsce. Określono wpływ sprawności elektrycznej modułu kogeneracyjnego (CHP - combined heat and power) i eksploatacyjnego wskaźnika skojarzenia na podstawowe składniki kosztów i przychodów z eksploatacji układu. Przeprowadzono analizę obliczeniową układu kogeneracyjnego z gazowym silnikiem tłokowym lub turbiną gazową zasilanych gazem ziemnym systemowym lub gazem z odmetanowania kopalni
Źródło:
Archiwum Energetyki; 2012, 42, 1; 39-51
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The theoretical model of the transient behaviour for the micro combined heat and power organic Rankine cycle
Teoretyczny model ciągły dla obiegu kogeneracyjnego ORC
Autorzy:
Matysko, R.
Mikielewicz, J.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/172873.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
układ mikro CHP
obieg ORC
modelowanie dynamiczne
wymiana ciepła
micro CHP system
ORC cycle
dynamical modelling
heat transfer
Opis:
W pracy przedstawiono wyniki obliczeń obiegu ORC w warunkach eksploatacyjnych. Przeprowadzone obliczenia umożliwiają określenie bezwładności układu podczas zmiany obciążeń cieplnych parownika i skraplacza. Z obliczeń uzyskano czasy bezwładności oraz parametry temperatury na dolocie do turbiny i skraplacza dla czynnika R123. Bardzo zbliżone wyniki obliczeń parametrów uzyskanych z własnego modelu obiegu ORC do przeprowadzonego niezależnie eksperymentu dają podstawy do stwierdzenia, że model dobrze odzwierciedla układy rzeczywiste. Podkreślić należy fakt, że obliczenia dynamiki obiegu za pomocą tego modelu przeprowadzono dla różnych czynników roboczych (R123, HFE7100, propan) uzyskując dobre jakościowo wyniki, co pozwala poszerzyć zakres jego stosowalności również na inne czynniki robocze. Wyniki własnych obliczeń porównano z badaniami eksperymentalnymi obiegu ORC innych autorów uzyskując dobrą zgodność.
This article presents results of calculations of the organic Rankine cycle (ORC) in working conditions. The calculations make it possible to define the inertia of the evaporator and condenser while the heat loads change occurs. Calculations allow to get the inertia of the system, and the parameters of temperature at the inlet to the turbine and condenser for the R123 refrigerant. Very similar calculations results of the parameters were obtained from own model for ORC cycle, and experiment results performed independently gave basis to conclude that the model well reflects the real systems. It should be emphasized that the dynamics calculations for the cycle prepared by this model was conducted for different working fluids (R123, HFE7100, propane). Good quality of the results from these calculations, allows to expand the scope of the model applicability to other working fluids. Our own results of calculations were compared with other authors experimental studies of the ORC cycle obtaining a good compliance.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 93-102
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy and economic effectiveness of gas-steam combined heat and power plants fired with natural gas
Efektywność energetyczna i ekonomiczna elektrociepłowni gazowo-parowych opalanych gazem ziemnym
Autorzy:
Zaporowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/172966.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrociepłownia gazowo-parowa
gaz ziemny
efektywność energetyczna
gas-steam power station
natural gas
energy efficiency
Opis:
The paper presents the energy and economic effectiveness analysis of technological systems of natural gas fired gas-steam combined heat and power (CHP) plants, operating in district heating systems. The analysis was performed for the following technological systems of gas-steam CHP plants: (1) gas-steam CHP plant with two-pressure heat recovery steam generator (HRSG) and extraction-condensing steam turbine, and (2) gas-steam CHP plant with three-pressure HRSG and extraction-condensing steam turbine. For particular kinds of technological systems of gas-steam CHP plants there were determined the following quantities characterizing their energy effectiveness: annual efficiency of electricity produced in cogeneration, annual efficiency of heat produced in cogeneration, annual overall efficiency, power to heat ratio and primary energy savings (PES). In the second part of the paper there is presented the analysis of the following quantities characterizing the economic effectiveness of natural gas fired gas-steam CHP plants: net present value (NPV), internal rate of return (IRR) and unitary electricity generation costs (EGC). The results of performed calculations of these quantities are presented in figures and in table.
W pracy przedstawiono analizę efektywności energetycznej i ekonomicznej układów technologicznych elektrociepłowni gazowo-parowych opalanych gazem ziemnym, pracujących w miejskich systemach ciepłowniczych. Analiza była wykonana dla następujących układów technologicznych elektrociepłowni gazowo-parowych: 1) elektrociepłowni gazowo-parowej z dwuciśnieniowym kotłem odzysknicowym i upustowo-kondensacyjną turbiną parową i 2) elektrociepłowni gazowo-parowej z trójciśnieniowym kotłem odzysknicowym i upustowo-kondensacyjną turbiną parową. Dla każdego z tych układów były wyznaczane następujące wielkości, charakteryzujące ich efektywność energetyczną: średnioroczna sprawność wytwarzania energii elektrycznej w skojarzeniu, średnioroczna sprawność wytwarzania ciepła w skojarzeniu, średnioroczna sprawność ogólna elektrociepłowni, wskaźnik skojarzenia oraz oszczędność energii pierwotnej. W drugiej części pracy jest przedstawiona analiza następujących wielkości charakteryzujących efektywność ekonomiczną elektrociepłowni gazowo-parowych opalanych gazem ziemnym: wartości bieżąca netto (ang. net present value - NPV), wewnętrznej stopa zwrotu (ang. internal rate of return IRR) oraz jednostkowych kosztów wytwarzania energii elektrycznej. Wyniki wykonanych obliczeń tych wielkości są przedstawione na wykresach i w tablicy.
Źródło:
Archiwum Energetyki; 2012, 42, 1; 123-137
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of supercritical coal-fired combined heat and power plant integrated with membrane carbon capture and storage installation
Analiza nadkrytycznej elektrociepłowni węglowej zintegrowanej z membranową instalacją CCS
Autorzy:
Bartela, Ł.
Kotowicz, J.
Janusz-Szymańska, K.
Powiązania:
https://bibliotekanauki.pl/articles/172857.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrociepłownia węglowa
blok CHP
membranowa instalacja CCS
coal power plant
CHP block
CCS membrane installation
Opis:
In the paper, the results of analysis of integrating chosen supercritical combined heat and power (CHP) unit with a membrane carbon capture and storage (CCS) installation are shown. As a way to improving the operation characteristics of such a system, the use of heat from cooling of permeate compressed in area of carbon capture installation for useful heat production is proposed. An additional source of heat is the cooling of carbon dioxide which is compressed for its preparation for transport to storage place. The considered use of cooling heat to useful heat production of leads to a reduction in steam consumption, and in consequence to an increase of steam turbine power. For two analyzed cases the influence of changing thermal load of unit on gross power and loads of heat exchangers is determined. The study involved the influence of assumed annual operation time of CHP unit on the basic thermodynamic characteristics: annual efficiency of electricity production, annual efficiency of heat production and annual overall efficiency. In conclusions, the paper highlighted the importance of the heat integration of CHP unit with CCS installation.
W artykule przedstawiono rezultaty analizy dotyczącej integracji wybranego nadkrytycznego bloku CHP z membranową instalacją CCS. Zaproponowano sposób na poprawę charakterystyk pracy takiego układu polegający na wykorzystaniu ciepła chłodzenia permeatu sprężanego w obrębie instalacji wychwytu dwutlenku węgla do produkcji ciepła użytkowego. Dodatkowym źródłem ciepła jest chłodzenie dwutlenku węgla sprężanego celem jego przygotowania do transportu do miejsca składowania. Rozpatrywane wykorzystanie ciepła chłodzenia jako ciepła grzewczego prowadzi do zmniejszenia poboru pary upustowej i w rezultacie do wzrostu mocy turbiny parowej. Dla dwóch analizowanych przypadków określono wpływ zmiany obciążeń cieplnych bloku na moc brutto oraz obciążenia poszczególnych wymienników ciepłowniczych. Badaniom poddano wpływ przyjętego czasu pracy elektrociepłowni w roku na podstawowe charakterystyki efektywności średniorocznej: średniorocznej sprawności wytwarzania energii elektrycznej, średniorocznej sprawności wytwarzania ciepła oraz średniorocznej sprawności ogólnej układu. W podsumowaniu pracy podkreślono duże znaczenie samej integracji bloku CHP z instalacją CCS po stronie cieplnej.
Źródło:
Archiwum Energetyki; 2011, 41, 3-4; 185-195
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza efektywności energetycznej i ekonomicznej elektrociepłowni gazowo-parowej zintegrowanej ze zgazowaniem biomasy
Energy and economic effectiveness analysis of gas-steam combined heat and power plant integrated with biomass gasification
Autorzy:
Zaporowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/172913.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrociepłownia gazowo-parowa
zgazowanie biomasy
efektywność energetyczna
efektywność ekonomiczna
gas-steam power plant
biomass gasification
energy effectiveness
economic effectiveness
Opis:
W artykule jest przedstawiona analiza efektywności energetycznej i ekonomicznej elektrociepłowni gazowo-parowej zintegrowanej ze zgazowaniem biomasy. W pierwszej części pracy zostały wyznaczone następujące wielkości charakteryzujące efektywność energetyczną procesu zgazowania biomasy: skład wytwarzanego gazu, wartość współczynnika nadmiaru czynnika zgazowującego, zużycie czynnika zgazowującego na 1 kg biomasy, objętość gazu uzyskiwana z 1 kg biomasy, wartość opałowa wytwarzanego gazu oraz sprawność chemiczna i energetyczna procesu zgazowania. W drugiej części została wykonana analiza efektywności energetycznej ciepłowniczego bloku gazowo-parowego z dwuciśnieniowym kotłem odzysknicowym i upustowo-kondensacyjną turbiną parową, zintegrowanego ze zgazowaniem biomasy. W trzeciej części zostały wyznaczone następujące wielkości charakteryzujące efektywność ekonomiczną analizowanego bloku ciepłowniczego: wielkość bieżąca netto, wewnętrzna stopa zwrotu oraz jednostkowe, zdyskontowane na rok 2012, koszty wytwarzania energii elektrycznej.
The paper presents the energy and economic effectiveness analysis of gas-steam combined heat and power (CHP) plant integrated with biomass gasification. In the first part of the paper there have been determined the following quantities characterizing the energy effectiveness of biomass gasification process: composition of gas, gasifying agent excess ratio, gasifying agent consumption per 1 kg of biomass, volume of gas obtained from 1 kg of biomass, lower heating value of gas and chemical and energy efficiencies of biomass gasification process. In the second part of the paper there has been made the analysis of energy effectiveness of gas-steam CHP block integrated with biomass gasification with two-pressure heat recovery steam generator (HRSG) and extraction condensing steam turbine. In the third part of the paper there have been determined the following quantities characterizing the economic effectiveness of the analyzed CHP block: net present value (NPV), internal rate of return (IRR) and unitary, discounted of 2012 year, electricity generation costs.
Źródło:
Archiwum Energetyki; 2012, 42, 2; s. 121-130
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic evaluation of a combined heat and power plant with carbon dioxide capture installation integrated with a gas turbine
Ocena termodynamiczna bloku elektrociepłowni współpracującej z instalacją wychwytu dwutlenku węgla przy jej integracji z turbiną gazową
Autorzy:
Bartela, Ł.
Skorek-Osikowska, A.
Rożek, M.
Powiązania:
https://bibliotekanauki.pl/articles/172973.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza termodynamiczna
wychwyt CO2
turbina gazowa
elektrociepłownia
thermodynamic analysis
CO2 capture
gas turbine
CHP plant
Opis:
The paper presents the results of a thermodynamic analysis carried out for a coal-fired combined heat and power plant (CHP) working at supercritical parameters, integrated with an absorption based carbon dioxide capture installation. The power of a plant was set at 320 MW, and it was assumed that it produces heat in accordance with heat demand characteristics. It was also assumed that in order to obtain heat for the desorption unit, the plant was integrated with a gas turbine installation, at the outlet of which a recovery heat exchanger was mounted. For the analysis, the values of the characteristic quantities of the gas turbine were adopted. Power of the machine, in turn, depended on the heat demand of the desorption process. For the evaluation of the integration of a CHP plant, the defined in the paper average annual thermodynamic quantities and unit carbon dioxide emissions were used.
W artykule przedstawiono rezultaty analizy termodynamicznej przeprowadzonej dla bloku elektrociepłowni węglowej na parametry nadkrytyczne zintegrowanej z absorpcyjną instalacją wychwytu dwutlenku węgla. Moc elektrociepłowni określono na poziomie 320 MW, zakładając, że produkuje ona ciepło zgodnie z przyjętymi charakterystykami zapotrzebowania. Założono ponadto, iż dla potrzeb pozyskania ciepła dla procesu desorpcji blok elektrociepłowni zintegrowany został z instalacją turbiny gazowej, na wylocie której zabudowano wymiennik odzyskowy. Dla celów analizy określono odpowiednie wielkości charakteryzujące turbinę gazową. Moc maszyny z kolei zależała od ciepłochłonności procesu desorpcji. Przy ocenie integracji elektrociepłowni posłużono się zdefiniowanymi w pracy średniorocznymi wskaźnikami termodynamicznymi oraz emisją jednostkową dwutlenku węgla.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 37-47
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies