The cooling rate of the heated vapor compression cycle in case of using refrigerants R134a, R22, and R600a
Autorzy:
Abd-Elhady, Mohamed Salama
Melad, Emmanoueil Bishara
Abd-Elhalim, Mohamed
Seif Alnasr, Ahmed
Powiązania:
https://bibliotekanauki.pl/articles/1845463.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
compression
cycle
power saving
refrigerant
refrigerating cycle
cooling rate
Opis:
The most power consuming part in the vapor compression cycle (VCC) is the gas compressor. Heating the refrigerant under constant volume after the compressor increases the condenser pressure, which consequently increases the cooling rate of the VCC. This study examined the influence of heating different refrigerants, i.e. R143a, R22, and R600a on the cooling rate of the VCC. Four experiments have been performed: the first experiment is a normal VCC, i.e. without heating, while in the second, third, and fourth experiments were carried out to raise the temperature of the refrigerant to 50◦C, 100◦C, and 150◦C. It has been found that heating raises the refrigerant pressure in VCC and thereby improves the refrigerant’s mass flow rate resulting in an improvement in the cooling power for the same compressor power. Heating the refrigerant after the mechanical compressor increases the temperature of the condenser as well as the temperature of the evaporator when using refrigerant R134a, which prevents the refrigeration cycle to be used in freezing applications, however using refrigerant R22 or refrigerant R600a promotes the heated VCC to be used in freezing applications. Refrigerant R600a has the lowest operating pressure compared to R134a and R22, which promotes R600a to be used rather than R134a and R22 from a leakage point of view.
Źródło:
Archives of Thermodynamics; 2021, 42, 2; 11-30
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of pressure drop during refrigerant condensation in pipe minichannels
Autorzy:
Sikora, M.
Bohdal, T.
Powiązania:
https://bibliotekanauki.pl/articles/240860.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
minichannels
pressure drop
refrigerant
condensation
minikanał
spadek ciśnienia
chłodziwo
kondensacja
Opis:
Investigations of refrigerant condensation in pipe minichannels are very challenging and complicated issue. Due to the multitude of influences very important is mathematical and computer modeling. Its allows for performing calculations for many different refrigerants under different flow conditions. A large number of experimental results published in the literature allows for experimental verification of correctness of the models. In this work is presented a mathematical model for calculation of flow resistance during condensation of refrigerants in the pipe minichannel. The model was developed in environment based on conservation equations. The results of calculations were verified by authors own experimental investigations results.
Źródło:
Archives of Thermodynamics; 2017, 38, 4; 15--28
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of flow structures during HFE-7100 refrigerant condensation
Autorzy:
Bohdal, T.
Sikora, M.
Widomska, K.
Radchenko, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/240718.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
minichannels
flow structures
refrigerant
kondensacja
minikanał
struktura przepływu
czynnik chłodniczy
Opis:
The experimental research of environmentally friendly refrigerant HFE-7100 condensation in pipe minichannels was conducted. During the investigations of HFE-7100 condensation in a minichannel with internal diameter 2 mm together with visualization of flow patterns was made. Visualization results were compared with existing flow structure maps. The identification of the range of flow patterns occurrence during the condensation process of low-pressure refrigerant HFE-7100 was made. The tests were performed throughout the whole range of condensation process.
Źródło:
Archives of Thermodynamics; 2015, 36, 4; 25-34
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Condensation of refrigerant R407C in multiport minichannel section
Autorzy:
Bohdal, T.
Charun, H.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/240486.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
minichannels
R407C refrigerant
heat exchanger
kondensacja
minikanały
czynnik chłodniczy R407C
wymiennik ciepła
Opis:
Analysis of the state of-the-art in research of refrigerant condensation in miniature heat exchangers, so-called multiports, was made. Results of refrigerant R407C condensation in a mini condenser made in the form of two bundles of tubular minichannels from stainless steel with an inside diameter 0.64 mm and length 100 mm have been presented. Two exchangers consisted of four minichannels and 8 minichannels have been investigated. The values of average heat transfer coefficient and frictional pressure drops throughout the condensation process were designated. The impact of the vapor quality of refrigerant and the mass flux density on the intensity of heat transfer and flow resistance were illustrated. A comparative analysis of test results for various refrigerants in both mini heat exchangers were made.
Źródło:
Archives of Thermodynamics; 2016, 37, 4; 3-18
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system
Autorzy:
Mishra, S.
Sarkar, J.
Powiązania:
https://bibliotekanauki.pl/articles/240184.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eco-friendly refrigerant
two-phase ejector
optimization
COP
area ratio
critical temperature
ekologiczny czynnik chłodniczy
strumienica dwufazowa
optymalizacja
stosunek powierzchni
temperatura krytyczna
Opis:
Performance assessment of ejector-expansion vapor compression refrigeration system with eco-friendly R134a alternative refrigerants (R152a, R1234yf, R600a, R600, R290, R161, R32, and propylene) is presented for air-conditioning application. Ejector has been modeled by considering experimental data based correlations of component efficiencies to take care of all irreversibilities. Ejector area ratio has been optimized based on maximum coefficient of performance (COP) for typical air-conditioner operating temperatures. Selected refrigerants have been compared based on area ratio, pressure lift ratio, entrainment ratio, COP, COP improvement and volumetric cooling capacity. Effects of normal boiling point and critical point on the performances have been studied as well. Using ejector as an expansion device, maximum improvement in COP is noted in R1234yf (10.1%), which reduces the COP deviation with R134a (4.5% less in basic cycle and 2.5% less in ejector cycle). Hence, R1234yf seems to be best alternative for ejector expansion system due to its mild flammability and comparable volumetric capacity and cooling COP. refrigerant R161 is superior to R134a in terms of both COP and volumetric cooling capacity, although may be restricted for low capacity application due to its flammability.
Źródło:
Archives of Thermodynamics; 2016, 37, 4; 55-72
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrid cascade refrigeration systems for refrigeration and heating
Autorzy:
Megdouli, K.
Ezzaalouni, Y.
Nahdi, E.
Mhimid, A.
Kairouani, L.
Powiązania:
https://bibliotekanauki.pl/articles/240448.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ejector cycle
heat pump
comparison
refrigerant
coefficient of performance
irreversibility
exergy loss
second law efficiency
pompa ciepła
porównanie
czynnik chłodniczy
współczynnik
efektywność
nieodwracalność
Opis:
In this study a cooling ejector cycle coupled to a compression heat pump is analyzed for simultaneous cooling and heating applications. In this work, the influence of the thermodynamic parameters and fluid nature on the performances of the hybrid system is studied. The results obtained show that this system presents interesting performances. The comparison of the system performances with hydrofluorocarbons (HFC) and natural fluids is made. The theoretical results show that the a low temperature refrigerant R32 gives the best performance.
Źródło:
Archives of Thermodynamics; 2018, 39, 2; 73-95
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies