Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heat exchange" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Investigations of thermal-flow characteristics of minichannel evaporator of air heat pump
Autorzy:
Kowalczyk, Michał Jan
Łęcki, Marcin
Romaniak, Artur
Warwas, Bartosz
Gutkowski, Artur
Powiązania:
https://bibliotekanauki.pl/articles/1955042.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CFD
numerical methods
heat exchange
minichannel
louvered fin
Opis:
The results of experimental investigations of heat transfer and a friction factor in an air channel of the minichannel heat exchanger are presented. The main aim of the analysis was to examine an influence of geometrical parameters of the fin shape with two geometries on heat transfer and flow characteristics of the air channel. The test rig was designed to monitor the parameters of the airflow during cooling by the minichannel heat exchanger. The analysis was conducted with the airflow in the range of 1–5 m/s. The temperature of the evaporation in a refrigeration system was set at 288.15 K. The energy balance of the refrigeration system was carried out. A numerical model describes the airflow through a part of the heat exchanger. Numerical simulations were validated with the experimental data. Numerical methods were used to evaluate the performance of the system and possibilities to improve the fin geometry. The characteristics of the friction factor (a measure of the pressure loss in the airflow) and the Colburn j-factor (heat transfer performance) were calculated. For the maximal velocity of the airflow, the Colburn factor was equal to 0.048 and the evaporator capacity equaled 1914 W.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 261-279
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the flow conditions in a high-performance heat exchanger
Autorzy:
Łopata, S.
Ocłoń, P.
Powiązania:
https://bibliotekanauki.pl/articles/240227.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
awaria
symulacja komputerowa
wymiana ciepła
computational simulation
failure
heat exchange
Opis:
CFD (Computational Fluid Dynamics) computations are carried out in order to investigate the flow distribution and its influence on the heat transfer processes in the high-performance heat exchanger. The subject of this investigation is the classical model of the high-performance heat exchanger with elliptical tubes and rectangular fins. It is possible to find the flow domains where the heat transfer conditions are impaired due to the fully developed turbulent flow. Therefore, the considerable thermal loads occur that may cause the breakdown of the heat exchanger. The emphasis of this investigation is put on the zones and the locations where the tubes are not properly fed with liquid, that result in occurrence of cavitation.
Źródło:
Archives of Thermodynamics; 2010, 31, 3; 37-53
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of energy efficiency and environmental safety of thermal energy through the implementation of contact energy exchange processes
Autorzy:
Varlamov, G. B.
Romanova, K. A.
Nazarova, I.
Daschenko, O.
Kapustiansky, A.
Powiązania:
https://bibliotekanauki.pl/articles/240126.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal efficiency
heat generator
energy consumption
contact hydrogen
contact energy exchange
sprawność cieplna
generator ciepła
zużycie energii
Opis:
Energy efficiency improvement and ecological safety of heat power plants are urgent problems, which require scientifically grounded approaches and solutions. These problems can be solved partly within the presented heat-and-power cycles by including contact energy exchange equipment in the circuits of existing installations. A significant positive effectis obtained in the contact energy exchange installations, such as gas-steam installation ‘Aquarius’ and the contact hydrogen heat generator that also can use hydrogen as a fuel. In these plants, the efficiency increases approximately by 10–12% in comparison with traditional installations, and the concentration of toxic substances, such as nitrogen oxides and carbon monoxide in flue gas can be reduced to 30 mg/m3 and to 5 mg/m3, respectively. Moreover, the plants additionally ‘generate’ the clean water, which can be used for technical purposes.
Źródło:
Archives of Thermodynamics; 2017, 38, 4; 127--137
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies