Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ventilation network" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Determining diagonal branches in mine ventilation networks
Wyznaczanie bocznic przekątnych w kopalnianej sieci wentylacyjnej
Autorzy:
Krach, A.
Powiązania:
https://bibliotekanauki.pl/articles/219890.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wentylacja kopalń
sieć wentylacyjna
bocznice przekątne
ventilation of mines
ventilation network
diagonal branches
Opis:
The present paper discusses determining diagonal branches in a mine ventilation network by means of a method based on the relationship A⊗ PT(k, l) = M, which states that the nodal-branch incidence matrix A, modulo-2 multiplied by the transposed path matrix PT(k, l ) from node no. k to node no. l, yields the matrix M where all the elements in rows k and l - corresponding to the start and the end node - are 1, and where the elements in the remaining rows are 0, exclusively. If a row of the matrix M is to contain only „0” elements, the following condition has to be fulfilled: after multiplying the elements of a row of the matrix A by the elements of a column of the matrix PT(k, l), i.e. by the elements of a proper row of the matrix P(k, l ), the result row must display only „0” elements or an even number of „1” entries, as only such a number of „1” entries yields 0 when modulo-2 added - and since the rows of the matrix A correspond to the graph nodes, and the path nodes level is 2 (apart from the nodes k and l, whose level is 1), then the number of „1” elements in a row has to be 0 or 2. If, in turn, the rows k and l of the matrix M are to contain only „1” elements, the following condition has to be fulfilled: after multiplying the elements of the row k or l of the matrix A by the elements of a column of the matrix PT(k, l), the result row must display an uneven number of „1” entries, as only such a number of „1” entries yields 1 when modulo-2 added - and since the rows of the matrix A correspond to the graph nodes, and the level of the i and j path nodes is 1, then the number of „1” elements in a row has to be 1. The process of determining diagonal branches by means of this method was demonstrated using the example of a simple ventilation network with two upcast shafts and one downcast shaft.
W artykule przedstawiono metodę wyznaczania bocznic przekątnych w sieci wentylacyjnej kopalni metodą bazującą na zależności A⊗PT(k, l) = M, która podaje, że macierz incydencji węzłowo bocznicowej A pomnożona modulo 2 przez transponowaną macierz ścieżek PT(k, l) od węzła nr k do węzła nr l daje w wyniku macierz M o takich własnościach że ma same jedynki w wierszach k i l, odpowiadającym węzłom początkowemu i końcowemu i same zera w pozostałych wierszach. Warunkiem na to, aby w wierszu macierzy M były same zera jest aby po pomnożeniu elementów wiersza macierzy A przez elementy kolumny macierzy PT(k, l), czyli przez elementy odpowiedniego wiersza macierzy P(k, l), w wierszu wynikowym były same zera lub parzysta liczba jedynek, ponieważ tylko taka liczba jedynek zsumowana modulo 2 daje w wyniku 0, a ponieważ wiersze macierzy A odpowiadają węzłom grafu, a węzły ścieżki są stopnia 2 (oprócz węzłów k i l, które są stopnia 1), to liczba jedynek w wierszu musi być równa 0 lub 2. Natomiast warunkiem na to, aby w wierszach k i l macierzy M były same jedynki jest aby po pomnożeniu elementów wiersza k lub l macierzy A przez elementy kolumny macierzy PT(k, l) w wierszu wynikowym była nieparzysta liczba jedynek, ponieważ tylko taka liczba jedynek zsumowana modulo 2 daje w wyniku 1, a ponieważ wiersze macierzy A odpowiadają węzłom grafu, a węzły k i j ścieżki są stopnia 1, to liczba jedynek w wierszu musi być równa 1. Wyznaczanie bocznic przekątnych tą metodą pokazano na przykładzie prostej sieci wentylacyjnej z dwoma szybami wydechowymi i jednym wdechowym.
Źródło:
Archives of Mining Sciences; 2014, 59, 4; 1097-1105
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of alternative characteristics of the vicinity of the ventilation district on air quantity
Autorzy:
Pach, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/220241.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wentylacja kopalni
rejon wentylacji
zagrożenie wentylacyjne
mine ventilation network
ventilation district
alternative characteristics
ventilation hazards
Opis:
Subnetwork with two nodes shared with entire ventilation network can be separated as its part. For the network under common ventilation conditions, one of these nodes will become the subnetwork starting node, while the other will be the subnetwork end node. According to the graphs theory, such a piece of the network can be considered as a subgraph of the graph representing the entire ventilation network. A special feature of that subgraph is lack of predecessors of the subnetwork starting node and lack of successors of the subnetwork end node. Ventilation district of a mine may be often treated as a subnetwork. Vicinity is a part of the network which is not separated as subnetwork. In the case of a ventilation district its vicinity forces air flow through the district. The alternative characteristic curve of the vicinity can therefore be compared to the characteristics curve of a fictional fan that forces the airflow in the district. The alternative characteristics (later in the text: the characteristics) of the vicinity of the ventilation district in an underground mine strongly influence air quantity and therefore play a crucial role in the reduction of methane, fire and thermal hazards. The role of these characteristics and proper selection of their approximating function were presented in the article. The reduction of resistance of an intake stopping (having influence on entire resistance of a ventilation district) produces increased airflow in the district. This changes of airflow in the district caused by a variation in internal resistance (e.g. by opening an internal regulation stopping) depends on the characteristic of the vicinity of the district. Proper selection of its approximating function is also important for this matter. The methods of determination of the alternative characteristic curve of the district vicinity are presented. From these procedures it was possible to obtain the results of air quantities and differences in isentropic potentials between an inlet and an outlet to/from the ventilation district. Following this, the characteristics were determined by graphic and analytic methods. It was proved that, in contrast to flat vicinity characteristics, steep ones have a smaller influence on the airflow modification in the district (which are caused by a regulation of the district resistance). The characteristic curve of the vicinity determines the ability to regulate air quantity and velocity in the district.
Źródło:
Archives of Mining Sciences; 2020, 65, 1; 47-58
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Costs reduction of main fans operation according to safety ventilation in mines – a case study
Redukcja kosztów pracy wentylatorów głównego przewietrzania przy zachowaniu bezpiecznej wentylacji – studium przypadków
Autorzy:
Pach, G.
Sułkowski, J.
Różański, Z.
Wrona, P.
Powiązania:
https://bibliotekanauki.pl/articles/220263.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kopalniana sieć wentylacyjna
rozpływ wymuszony powietrza
prądy zależne
koszty wentylacji
optymalizacja rozpływu powietrza
bezpieczna wentylacja kopalni
mine ventilation network
forced airflow
dependent air streams
ventilation costs
airflow optimization
safe mining ventilation
Opis:
Considering the various hazards present in an underground mine, safe ventilation entails maintaining a certain airflow rate in the mining workings. The air velocity, airflow rate and air composition must be regulated in a ventilation network by operation of the main fans. On the other hand, ventilation costs must be minimized. Thus, the optimal solution is when the requisite safety features are fulfilled and the power output of the fans is at a minimal yet sufficient rate. In real-world mines, it is common to have airstreams interlinking subnets of the main fans. The current restructuring of the mining sector commonly involves the connection of different mines, which leads to an increase in the number of such cases. This article presents the results of research into ventilation networks containing these kind of airstreams and introduces a new method for reducing ventilation costs. The method is based on an algorithm which allows the determination of the resistance of a stopping, the head of the fans and the air quantity for which air distribution is optimal. As a result, the total power output of the fans is at the lowest level that yields a reduction in ventilation costs. The method was applied for two theoretical examples and a practical one which was taken from a real ventilation network. In the first example, fan power output was reduced by 17.252 kW, which gave an annual reduction of 188.909 MWh, and an annual electricity cost reduction of €27014. Therefore, optimization enabled a saving of approximately 14% of the costs. In the second example, power output was reduced by 106.152 kW, which produced an annual reduction of 1162.364 MWh, and an annual electricity cost reduction of €166218. In this case, optimization allowed a reduction in costs of approximately 40%. Considering both examples, the cost reductions did not affect the safe airflow rate. For the real-world mine, the annual savings were 2343 MWh, which corresponds to approximately €335000.
Ze względu na zagrożenia występujące w podziemnej kopalni bezpieczna wentylacja powinna zapewniać dostarczenie właściwego wydatku objętościowego powietrza do wyrobisk górniczych. Wentylatory głównego przewietrzania powinny zapewnić w wyrobiskach bezpieczną prędkość powietrza oraz jego skład chemiczny . Jednocześnie ze względów ekonomicznych istotna jest minimalizacja jej kosztów. Celem więc jest znalezienie optymalnego rozpływu powietrza uwzględniającego bezpieczeństwo górników i minimalizującego zużycie energii przez wentylatory. W istniejących kopalniach występują prądy powietrza łączące podsieci wentylatorów głównego przewietrzania. Aktualnie prowadzona restrukturyzacja górnictwa polegająca także na łączeniu kopalń przyczynia się do zwiększenia liczby takich prądów. W artykule zaprezentowano wyniki badań nad sieciami wentylacyjnymi zawierającymi wspomniane prądy powietrza. Przedstawiono nową metodę pozwalającą na obniżenie kosztów wentylacji. Przedstawiony w pracy algorytm pozwala na wyznaczenie wartości oporu tamy regulacyjnej oraz spiętrzenia i wydajności wentylatorów, przy których rozpływ powietrza jest optymalny. Uzyskiwana przy nim wartość sumarycznej mocy użytecznej wentylatorów jest najniższa, co przyczynia się do obniżenia kosztów związanych z wentylacją. W artykule przedstawiono wyniki optymalizacji przeprowadzonej według nowej metody dla dwóch przykładów teoretycznych oraz dla rzeczywistej sieci wentylacyjnej kopalni. W pierwszym przykładzie uzyskano zmniejszenie mocy użytecznej wentylatorów o 17 252 W, rocznego zużycia energii 188 909 kWh, rocznych kosztów za energię elektryczna 113 345 zł. Oszczędności wyniosły 14% względem stanu przed optymalizacja. Dla drugiego przykładu uzyskano odpowiednio spadki: mocy o 106 152 W, rocznego zużycia energii o 1 162 364 kWh, rocznych kosztów 697 418 zł. W tym przykładzie zastosowanie metody pozwoliłoby uzyskać oszczędności na poziomie 40%. Dla rzeczywistej kopalni roczne oszczędności wyniosły 2 343 MWh, co odpowiada w przybliżeniu 335 000 Euro.
Źródło:
Archives of Mining Sciences; 2018, 63, 1; 43-60
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies