Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Major, B" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Contribution of titanium, chromium and carbon buffer interlayers to bio-tribological properties of multilayer composites
Autorzy:
Major, Ł.
Janusz, M.
Lackner, J. M.
Major, B.
Powiązania:
https://bibliotekanauki.pl/articles/352343.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bio-tribological coatings
wear mechanism
microstructure
Opis:
Research studies on bio-tribological protective coatings of titanium, chromium and carbon based have been performed. Thin films were fabricated by hybrid PLD technique (PLD supported by magnetron sputtering). Coatings consisted of two parts; the inner part (first from the substrate) in each case was formed by titanium or chromium/titanium nitride or chromium nitride (Ti/TiN or Cr/Cr2N). The outer part was formed by pure DLC or multilayer DLC'Ti or Cr. No delamination was found at the interface. Titanium or chromium metallic layer was deposited as a first layer directly on the metallic substrate to avoid delamination. All individual layers were built of columnar nano- crystallites. Mechanisms of the mechanical wear of analyzed systems were presented, focusing on the cracking propagation in ball-on-disc tests using an 1 N and 5 N applied loads for 5 000 cycles. Complex microstmcture analysis of presented nano-multilayer coatings, before and after mechanical tests, were performed by means of transmission electron microscopy (TEM). The highest stress concentration during mechanical uploading was moved through the multilayer coating by breaking only one layer at the time. The microstructure characterization revealed that cracking propagating in the outer part of the coating was stopped at the interface. In the case of the inner part of the coating Ti/TiN; Cr/Cr2N, ceramic layers showed brittle cracking, while metallic (Ti or Cr) ones deformed plastically. Fabricated coatings were subjected under the analysis in the biomechanical system optimized to test for the direct contact with a human whole blood. The study considered physiological conditions mainly related to the temperature and humidity and the frequency of cyclic deformation of the artificial vessel into which the tested sample was introduced.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1391-1398
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dry And Ringer Solution Lubricated Tribology Of Thin Osseoconductive Metal Oxides And Diamond-Like Carbon Films
Tribologia suchych i smarowanych roztworem Ringera cienkich filmów na bazie tlenków metali i diamentopodobnych promujących procesy ostointegracyjne
Autorzy:
Waldhauser, W.
Lackner, J. M.
Kot, M.
Major, B.
Powiązania:
https://bibliotekanauki.pl/articles/351772.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biotribology
thin films
lubrication
tribologia
cienki film
smarowanie
Opis:
Achieving fast and strong adhesion to jawbone is essential for dental implants. Thin deposited films may improve osseointegration, but they are prone to cohesive and adhesive fracture due to high stresses while screwing the implant into the bone, leading to bared, less osteoconductive substrate surfaces and nano- and micro-particles in the bone. Aim of this work is the investigation of the cohesion and adhesion failure stresses of osteoconductive tantalum, titanium, silicon, zirconium and aluminium oxide and diamond-like carbon films. The tribological behaviour under dry and lubricated conditions (Ringer solution) reveals best results for diamond-like carbon, while cohesion and adhesion of zirconium oxide films is highest.
Osiągnięcie szybkiego i trwałego przylegania powierzchni biomateriału do kości szczęki ma zasadnicze znaczenie dla implantów dentystycznych. Cienkie osadzone filmy mogą poprawić osteointegrację ale są podatne na kohezyjne i adhezyjne pękanie podczas wkręcania implantu do kości, prowadząc do odsłoniecia mniej osteokonduktywnych powierzchni podłoża oraz powodując tworzenie się nano- i mikro cząstek. Celem niniejszej pracy są badania naprężeń wywołujących defekty w osteointegracyjnych filmach na bazie tantalu, tytanu, cyrkonu oraz tlenku aluminium i diamentopodobnych. Tribologiczne najlepsze właściwości w warunkach suchych i smarowania (roztwór Ringera) wykazały powłoki diamentopodobne, natomiast spójność i przyczepność filmy z tlenku cyrkonu.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3; 2139-2144
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of surface modification methods for ReligaHeart® cardiac support system
Autorzy:
Major, R.
Kustosz, R.
Trembecka-Wójciga, K.
Lackner, J. M.
Major, B.
Powiązania:
https://bibliotekanauki.pl/articles/352605.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ReligaHeart® cardiac support system
pneumatic heart
blood-polymer barrier
proangiogenic effect
Opis:
The work is a review of the methods of the surface modification performed by the authors dedicated for for cardiac support system. It presents the evolution of designing the surface dedicated to direct contact with blood. Initially thin and ultrathin coatings were developed. They were designed as a blood-polymer barrier. The pneumatic heart assist devices are made of a medical grade polyurethane. A major milestone was to create advanced ceramic thin films expressing the flexible effects deposited by physical techniques. Coatings have evolved. Another milestone was the surface reproducing the microenvironment to capture progenitor cells from the bloodstream. Thin coatings were prepared, using methods of ion been, controlled residual stresses were introduced. Wrinkles appeared without cracking. This enabled taking control over the process of cell differentiation. Alternatively, the tissue inspired structure resulted of the coating in the form of extracellular matrix. The outer surface was modified with synthetic materials. This enabled the effective proteins docking to induce cell growth, recreating the luminal side of the blood vessel. Coagulation processes have been slowed down. In addition, it was found pro-angiogenic effect.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1399-1404
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Roughness Influence on Macro- and Micro-Tribology of Multi-Layered Hard Coatings on Carbon Fibre Polymer Composite
Wpływ chropowatości na makro- i mikro-tribologię wielowarstwowych twardych powłok na bazie zbrojonych włóknami kompozytów polimerowych
Autorzy:
Lackner, J. M.
Major, B.
Waldhauser, W.
Mzyk, A.
Major, Ł.
Kot, M.
Powiązania:
https://bibliotekanauki.pl/articles/354807.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
carbon fibre reinforced polymers
hard coatings
multi-layer
roughness
tribology
polimery węglowe wzmocnione włóknami
twarde powłoki
powłoki wielowarstwowe
chropowatość
tribologia
Opis:
Goal of this work is the investigation of roughness influences on the abrasive wear behaviour of magnetron sputtered multi- -layered, low-friction coatings on carbon-fibre reinforced polymers (CFRP). Higher coating roughness at similar CFRP quality was realized by higher deposition rates, leading to increased heat flux to the substrates during deposition. Thermal expansion of the epoxy matrix on the micro scale results in a wavy, wrinkled surface topography. Both in scratch and reciprocal sliding testing against alumina, the friction coefficients are lower for the smooth coatings, but their wear rate is higher due to low-cycle fatigue caused abrasion.
Celem pracy jest badanie wpływów szorstkości na zużycia abrazyjne osadzonych magnetronowo wielowarstwowych powłoki o niskim współczynniku tarcia na bazie wzmocnionych włóknami węglowych polimerów (CFRP). Większa szorstkość powłoki przy podobnej jakości (CFRP) została uzyskana przez wyższe szybkości osadzania, co prowadziło do zwiększonego strumienia ciepła do podłoża podczas osadzania. Rozszerzalność cieplna matrycy epoksydowej w skali mikro pozwalała na uzyskanie falistej, pofałdowanej topografii powierzchni. Zarówno w teście zarysowania jak i ścierania z przeciwpróbką korundową uzyskano niższe współczynniki tarcia dla gładkich powierzchni zaś ich szybkość zużycia była wyższa ze względu na nisko-cyklowe zmęczenie wywołujace przetarcie.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3; 2145-2151
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies