Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "PM2.5" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
The use of the GIS tools in the analysis of air quality on the selected University campus in Poland
Zastosowanie narzędzi GIS w analizie jakości powietrza atmosferycznego na terenie wybranego kampusu uczelni wyższej w Polsce
Autorzy:
Sówka, Izabela
Badura, Marek
Pawnuk, Marcin
Szymański, Piotr
Batog, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/205444.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PM2.5
ordinary kriging
campus area
PM2,5
zwykły kriging
kampus uczelni
Opis:
In our article the ordinary kriging interpolation method was used for a spatial presentation of PM2.5 concentrations. The data used in the research was obtained from the unique PM2.5 measuring system, based on low-cost optical sensors for PM2.5 concentration measurements, working on Wroclaw University of Science and Technology campus area. The data from this system was used as an input for the interpolations that were made for three different days characterized by the highest measured values of PM2.5 – 20.01.2019, 17.02.2019 and 30.03.2019. For each of the selected days, variants with the maximum and minimum PM2.5 values recorded on a given measurement day were presented. In the analyses performed, the ordinary kriging technique and cross-validation, was used as the interpolation and the validation method, respectively. Parameters determining the quality of performed interpolation were Mean Error, Mean Standardized Error, Root Mean Square Error, and Average Standard Error. As the main indicator of quality of interpolation RMSE parameter was used. Analysis of that parameter shows that the higher variability of the data used for interpolation affects its quality. The Root Mean Square Error parameter reached 0.64, 0.94 and 1.71 for the lowest concentrations variants characterized by low spatial variability, and 6.53, 7.51, 11.28 for the highest one, which were characterized by high spatial variability. The obtained results of the research with the use of GIS tools shows that the ordinary kriging method allowed for the correct spatial presentation of the PM2.5 concentration variability in areas not covered by the measurement system.
W artykule przedstawiono wyniki analiz przestrzennych zmienności stężeń pyłu PM2.5 uzyskanych z pomiarów przeprowadzonych przy zastosowaniu systemu nisko kosztowych czujników zlokalizowanych na terenie kampusu Politechniki Wrocławskiej dla scenariuszy trzech dni w okresie zimowym charakteryzujących się wartościami podwyższonych stężeń PM2.5 na badanym obszarze – 20/01/2019, 17/02/2019 i 30/03/2019. Dla każdego z wybranych dni przedstawiono warianty z odnotowanymi maksymalnymi oraz minimalnymi wartościami stężeń PM2.5 zanotowanych w danym dniu pomiarowym. W przeprowadzonych analizach jako metodę interpolacji wykorzystano technikę krigingu zwykłego, a jako metodę walidacji walidację krzyżową. Parametrami określającymi poprawność wykonanej interpolacji były Mean Error, Mean Standardized Error, Root Mean Square Error oraz Average Standard Error. Z przeprowadzonych badań i analiz wynika, iż większa zmienność danych użytych do interpolacji wpływa na jej jakość oraz iż dla wariantów obliczeniowych, w których analizowane były stężenia minimalne w danym dniu pomiarowym uzyskano mniejsze wartości błędów interpolacji. Parametr Root Mean Square Error będący głównym wskaźnikiem jakości wykonanych interpolacji dla stężeń najniższych osiągnął wartość równe 0.64, 0.94 oraz 17.71, w przypadku najwyższych – 6.53, 7.51, 11.28. Metoda krigingu zwykłego umożliwiła na jakościowo poprawną przestrzenną prezentację zmienności stężeń pyłów PM2.5.
Źródło:
Archives of Environmental Protection; 2020, 46, 1; 100-106
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seasonal variations of PM2.5 and PM10 concentrations and inhalation exposure from PM-bound metals (As, Cd, Ni) : first studies in Poznań (Poland)
Analiza zmienności stężeń PM2.5 i PM10 wraz z oceną narażenia inhalacyjnego na metale ciężkie w PM10 (As, Cd i NI) : pierwsze badania w Poznaniu
Autorzy:
Sówka, I.
Chlebowska-Styś, A.
Pachurka, Ł.
Rogula-Kozłowska, W.
Powiązania:
https://bibliotekanauki.pl/articles/205482.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PM2.5
PM10
cancer risk
Poznań
PM-bounds
PM2,5
ryzyko raka
średnie roczne stężenia PM
Opis:
Results of measurements of suspended particulate matter concentrations – PM10 and PM2..5 (ambient particles with aerodynamic diameter not greater than 10 and 2.5 μm respectively) in Poznań, Poland in years 2010–2016 alongside the results of cancer risk assessment analysis in relation to inhalation exposure to selected heavy metals: As, Cd and Ni related to PM103 in 2010 at the measurement station on Szymanowskiego street to 39 μg/m3 in 2016 at measurement stations on Polanka and Dąbrowskiego streets. Mean concentrations in the heating season were twice higher than in non-heating season at stations on Szymanowskiego street, Polanka street and Dąbrowskiego street. In the case of heavy metals, the highest average seasonal concentrations were: 3.34 ng/m3 for As in the heating season of 2016 (Chwiałkowskiego street), 0.92 ng/m3 for Cd in the heating season of 2012 (Chwiałkowskiego street), 10.82 ng/m3 for Ni in the heating season of 2016 (Szymanowskiego street). We have shown that the presence of As in PM in Poznań is connected with fossil fuel emission from home fireplaces. Road traffic and industry were a potential source of Cd and Ni. The highest risk values for residents of Poznań were acquired for average concentrations in the heating seasons from 2012–2016 of As and they were: 24.27·10-6 for children, 11.87·10-6 for women and 9.94·10-6 for men. Received risk value on an acceptable level according to US EPA is 1·10-6.
Celem pracy była analiza zmienności sezonowej stężeń PM2.5 i PM10 w Poznaniu wraz z oceną wpływu inhalacyjnego wybranych metali ciężkich związanych z PM10 (As, Cd i Ni) na mieszkańców. W pracy przedstawiono wyniki pomiarów stężenia pyłu zawieszonego PM10 i PM2.5 w Poznaniu w latach 2010-2016 oraz wyniki analizy oceny ryzyka zachorowania na raka w odniesieniu do ekspozycji inhalacyjnej na wybrane wartości PM: As, Cd, Ni. Dane wykorzystane w zestawieniu pochodzą z pomiarów WIOŚ i badań własnych. Przedstawione zostały średnie roczne stężenia PM w rozpatrywanym okresie wraz z analizą jego sezonowej zmienności. W celu określenia ryzyka autorzy wykorzystali metodologię oceny ryzyka US EPA. Średnie roczne stężenia PM10 kształtowały się w przedziale od 21 g/m3 w 2010 r. (ul. Szymanowskiego) do 39 g/m3 w 2016 roku (ul. Polanka i Dąbrowskiego). W przypadku metali ciężkich najwyższą wartość stężenia As (3,34 ng/m3) określono w sezonie grzewczym 2016 r. (ul. Chwiałkowskiego), stężenia Cd (0,92 ng/m3) w sezonie grzewczym w 2012 r. (ul. Chwiałkowskiego) oraz stężenia Ni (10,82 ng/m3) w sezonie grzewczym 2016 roku (ul. Szymanowskiego) Przeprowadzone obliczenia wskazały na najwyższe wartości ryzyka dla danych zebranych w latach 2012-2016 w sezonie grzewczym i wyniosły odpowiednio dla dzieci: 24,27-10-6, kobiet: 11,87 10-6 i mężczyzn: 9,9410-6. Wartość ryzyka na poziomie akceptowalnym zgodnie z US EPA wynosi 1‧10-6.
Źródło:
Archives of Environmental Protection; 2018, 44, 4; 86-95
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of PM2.5 hourly concentrations in Beijing based on machine learning algorithm and ground-based LiDAR
Autorzy:
Fang, Zhiyuan
Yang, Hao
Li, Cheng
Cheng, Liangliang
Zhao, Ming
Xie, Chenbo
Powiązania:
https://bibliotekanauki.pl/articles/2073773.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PM2.5
LiDAR
machine learning
air pollution monitoring
Opis:
The prediction of PM2.5 is important for environmental forecasting and air pollution control. In this study, four machine learning methods, ground-based LiDAR data and meteorological data were used to predict the ground-level PM2.5 concentrations in Beijing. Among the four methods, the random forest (RF) method was the most effective in predicting ground-level PM2.5 concentrations. Compared with BP neural network, support vector machine (SVM), and various linear fitting methods, the accuracy of the RF method was superior by 10%. The method can describe the spatial and temporal variation in PM2.5 concentrations under different meteorological conditions, with low root mean square error (RMSE) and mean square deviation (MD), and the consistency index (IA) reached 99.69%. Under different weather conditions, the hourly variation in PM2.5 concentrations has a good descriptive ability. In this paper, we analyzed the weights of input variables in the RF method, constructed a pollution case to correspond to the relationship between input variables and PM2.5, and analyzed the sources of pollutants via HYSPLIT backward trajectory. This method can study the interaction between PM2.5 and air pollution variables, and provide new ideas for preventing and forecasting air pollution.
Źródło:
Archives of Environmental Protection; 2021, 47, 3; 98--107
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hazardous Compounds in Urban Pm in the Central Part of Upper Silesia (Poland) in Winter
Niebezpieczne związki w miejskim pyle zawieszonym w centralnej części Górnego Śląska w zimie
Autorzy:
Rogula-Kozłowska, W.
Kozielska, B.
Klejnowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/204935.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pył zawieszony
pył PM2,5
pył PM1
metale ciężkie
WWA
wielopierścieniowe węglowodory aromatyczne
związki rakotwórcze
jakość powietrza
Zabrze
PM1
PM2,5
heavy metals
PAH
benzo(a)pyrene
carcinogenicity
hazardous compounds
toxicity equivalency factor
BEQ
Opis:
Thirteen fractions of ambient dust were investigated in Zabrze, a typical urban area in the central part of Upper Silesia (Poland), during a heating season. Fifteen PAH and Cr, Mn, Co, Ni, As, Se, Cd, Pb contents of each fraction were determined. The dust was sampled with use of a cascade impactor and chemically analyzed with an energy dispersive X-ray fl uorescence spectrometer (PANalytical Epsilon 5) and a gas chromatograph with a fl ame ionisation detector (Perkin Elmer Clarus 500). The concentrations of PM1 and the PM1-related PAH and elements were much higher than the ones of the coarse dust (PM2.5-10) and the substances contained in it. The concentrations of total PAH and carcinogenic PAH were very high (the concentrations of PM1-, PM2.5-, and PM10-related BaP were 16.08, 19.19, 19.32 ng m-3, respectively). The municipal emission, resulted mainly from hard coal combustion processes, appeared to be the main factor affecting the air quality in Zabrze in winter.
Próbki trzynastu frakcji pyłu zawieszonego były pobierane w Zabrzu w okresie grzewczym (centralna część Górnego Śląska, Polska). Punkt poboru jest charakterystyczny dla obszaru miejskiego. Zbadano zawartość 15 WWA oraz Cr, Mn, Co, Ni, As, Se, Cd, Pb w każdej frakcji pyłu. Do poboru pyłu zastosowano impaktor kaskadowy, a do analizy chemicznej – spektrometr fl uorescencji rentgenowskiej z dyspersją energii (PANalytical Epsilon 5) oraz chromatograf gazowy z detektorem płomieniowo-jonizacyjnym (Perkin Elmer Clarus 500). Zarówno stężenia pyłu PM1 jak i stężenia związanych z nim WWA i pierwiastków były znacznie wyższe niż stężenia pyłu grubego (PM2.5-10) i związanych z nim substancji. Stężenia sumy WWA, a w szczególności kancerogennych związków tej grupy były bardzo wysokie (np. stężenia dla BaP związanego z PM1- i PM2.5- oraz PM10- wynosiły odpowiednio: 16.08, 19.19, 19.32 ng m-3). Na podstawie uzyskanych wyników badań dla ww. zanieczyszczeń stwierdzono, że za stan jakości powietrza w Zabrzu, w zimie, odpowiedzialna jest emisja komunalna – stacjonarne źródła spalania, głównie spalanie węgla.
Źródło:
Archives of Environmental Protection; 2013, 39, 1; 53-65
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spatial analysis of air masses backward trajectories in order to identify distant sources of fine particulate matter emission
Analiza przestrzenna wstecznych trajektorii mas powietrza w celu rozpoznania odległych źródeł emisji pyłu drobnego
Autorzy:
Godłowska, J.
Hajto, M. J.
Tomaszewska, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/204690.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
backward trajectories
air masses
emission sources
particulate matter
PM2.5
trajektoria wsteczna
masy powietrza
źródła emisji
pył zawieszony
Opis:
The paper presents a method of identifying distant emission sources of fine particulate matter PM2.5 affecting significantly PM2.5 concentrations at a given location. The method involves spatial analysis of aggregate information about PM2.5 concentrations measured at the location and air masses backward trajectories calculated by HYSPLIT model. The method was examined for three locations of PM2.5 measurement stations (Diabla Góra, Gdańsk, and Katowice) which represented different environmental conditions. The backward trajectories were calculated starting from different heights (30, 50, 100 and 150 m a. g. l.). All points of a single backward trajectory were assigned to the PM2.5 concentration corresponding to the date and the site of the beginning of trajectory calculation. Daily average concentrations of PM2.5 were used, and in the case of Gdańsk also hourly ones. It enabled to assess the effectiveness of the presented method using daily averages if hourly ones were not available. Locations of distant sources of fine particulate matter emission were determined by assigning to each grid node a mean value of PM2.5 concentrations associated with the trajectories points located within the so-called search ellipse. Nearby sources of fine particulate matter emission were eliminated by filtering the trajectories points located close to each other (so-called duplicates). The analyses covered the period of January-March 2010. The results indicated the different origin of air masses in the northern and southern Poland. In Diabla Góra and Gdańsk the distant sources of fine particulate matter emission are identified in Belarus and Russia. In Katowice the impact of the Belarusian PM2.5 emission sources was also noted but as the most important fine particulate matter emission sources were considered those located in the area of Romania, Hungary, Slovakia and Ukraine.
W pracy zaprezentowano metodę rozpoznawania odległych źródeł emisji pyłu drobnego PM2.5, polegającą na przestrzennej analizie łącznej informacji o imisji PM2.5 oraz o wstecznych trajektoriach mas powietrza, obliczonych za pomocą modelu HYSPLIT. Trajektorie wsteczne obliczono startując z wysokości 30, 50, 100 i 150 m n.p.g., dla trzech lokalizacji stacji pomiarowych stężeń PM2.5 (Diabla Góra, Gdańsk, Katowice), reprezentujących różne warunki środowiskowe. Wszystkim punktom pojedynczej trajektorii wstecznej przyporządkowano stężenie PM2.5 odpowiadające dacie startu obliczeń tej trajektorii. Użyto dobowych średnich stężeń PM2.5, a w przypadku Gdańska dodatkowo także godzinnych średnich, co umożliwiło ocenę skuteczności przedstawionej metody. Położenie odległych źródeł emisji pyłu drobnego zostało określone poprzez interpolację danych punktowych trajektorii do regularnej siatki przy zastosowaniu metody metryki danych. Każdemu węzłowi siatki przypisano wartość średnią obliczoną ze stężeń PM2.5 przyporządkowanych punktom trajektorii znajdujących się w obrębie tzw. elipsy wyszukiwania. Przed obliczeniem wartości średniej ukryto część danych, eliminując w ten sposób bliskie źródła emisji pyłu drobnego. Analizy objęły okres styczeń-marzec 2010 roku. Wyniki wskazały na odmienne pochodzenie mas powietrza w północnej i południowej Polsce. W Diablej Górze i Gdańsku odległe źródła emisji pyłu drobnego rozpoznano głównie w Białorusi i Rosji. W Katowicach również zaznaczył się wpływ źródeł białoruskich, ale jako najbardziej istotne odległe źródła emisji PM2.5 uznano te zlokalizowane na obszarze Rumunii, Węgier, Słowacji i Ukrainy.
Źródło:
Archives of Environmental Protection; 2015, 41, 2; 28-35
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metals distribution on the surface of quartz fiber filters used for particulate matter collection
Rozkład metali na powierzchni filtrów kwarcowych stosowanych do poboru pyłu zawieszonego
Autorzy:
Widziewicz, K.
Loska, K.
Rogula-Kozłowska, W.
Powiązania:
https://bibliotekanauki.pl/articles/204939.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
particulate matter
PM2.5
metals
quartz fiber filters
homogeneity
distribution
pył zawieszony
rozkład metali
filtr kwarcowy
spektroskopia atomowa
Opis:
Presented study aimed to determine metals distribution on the quartz fiber filters surface coated with particulate matter by using high and low-volume samplers. The distribution pattern was tested using two different sub-sampling schemes. Each sub-sample was mineralized in the nitric acid in a microwave oven. An analysis was performed by means of atomic absorption spectroscopy with electrothermal atomization GF-AAS technique, and the determined elements were: As, Cd, Pb and Ni. A validation of the analytical procedure was carried out using NIES 28 Urban Aerosols standard reference material. It was assumed that metal is distributed uniformly if its normalized concentrations on a single sub-sample is within ±15% of the mean concentration over the whole filter. The normalized concentrations values exceed this range, indicating a non-homogenous metals distribution. There were no statistically significant differences in metals concentrations between particular sub-samples in the function of its position along the filters diameter.
Praca miała na celu zbadanie rozkładu metali na powierzchni filtrów kwarcowych pokrytych pyłem zawieszonym zebranym przy użyciu wysoko- oraz niskoprzepływowych analizatorów powietrza. Rozkład badano przy użyciu dwóch różnych systemów podpróbkowania filtrów. Każdą podpróbkę mineralizowano w kwasie azotowym w piecu mikrofalowym. Analizę przeprowadzono techniką absorpcyjnej spektroskopii atomowej z atomizacją elektrotermiczną GT–AAS, za pomocą której oznaczano następujące pierwiastki: As, Cd, Pb i Ni. Walidację procedury analitycznej przeprowadzono przy użyciu certyfikowanego materiału odniesienia NIES28 Urban Aerosols. Założono, że metal jest rozłożony na powierzchni filtra równomiernie, jeśli jego znormalizowane stężenie na pojedynczej podpróbce mieści się w zakresie ±15% średniego stężenia na całym filtrze. Ponieważ wartości znormalizowanych stężeń metali przekraczały ten zakres, wskazywało to jednoznacznie na nierównomierny ich rozkład na powierzchni filtrów. Nie stwierdzono statystycznie istotnych różnic w stężeniach metali pomiędzy poszczególnymi fragmentami filtrów w funkcji ich położenia względem średnicy filtrów.
Źródło:
Archives of Environmental Protection; 2015, 41, 4; 3-10
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies