Investigation of the stator inductances of the expanded Park model and an approach on parameter identification using the evolution strategy
Autorzy:
Schmuelling, Ch.
Kreischer, Ch.
Gołebiowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/141147.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
evolution strategy
FEM
Park equations
Park theory
synchronous machines
transients
Opis:
Commonly, the Park model is used to calculate transients or steady-state operations of synchronous machines. The expanded Park theory derives the Park equations from the phase-domain model of the synchronous machine by the use of transformations. Thereby, several hypothesis are made, which are under investigation in this article in respect to the main inductances of two different types of synchronous machines. It is shown, that the derivation of the Park equations from the phase-domain model does not lead to constant inductances, as it is usually assumed for these equations. Nevertheless the Park model is the most common analytic model of synchronous machines. Therefore, in the second part of this article a method using the evolution strategy is shown to obtain the parameters of the Park model.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 585-599
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of synchronous generators for the analysis of frequency transients above 1 Hz/s
Autorzy:
Assenkamp, Alf
Powiązania:
https://bibliotekanauki.pl/articles/2135729.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
control system
distributed energy systems
frequency support
generator model
RoCoF
synchronous generators
synchronous machines
Opis:
Large synchronous generators are of high importance for the stability of power systems. They generate the frequency of the system and stabilize it in case of severe grid faults like trips of large in-feeders or loads. In distributed energy systems, in-feed via inverters will replace this generation in large parts. Modern inverters are capable of supporting grid frequency during severe faults by different means on the one hand. On the other hand, higher Rates of Change of Frequency (RoCoF) after incidents need to be accustomed by future systems. To be able to analyse the RoCoF withstand capability of synchronous or induction generators, suitable models need to be developed. Especially the control and excitation system model need enhancements compared to models proposed in standards like IEEE Std 421.5. This paper elaborates on the necessary modelling depth and validates the approach with example results.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 687--700
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified concept of permanent magnet excited synchronous machines with improved high-speed features
Autorzy:
May, H.
Palka, R.
Paplicki, P.
Szkolny, S.
Canders, W.-R.
Powiązania:
https://bibliotekanauki.pl/articles/140362.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pojazd elektryczny
magnes trwały
maszyna synchroniczna
osłabianie pola
electric vehicles
permanent magnet
synchronous machines
field weakening
optimal feeding
Opis:
Permanent magnet (PM) excited synchronous machines used in modern drives for electro-mobiles suffer in high speed regions from the limited battery-voltage. The field weakening requires designing machines with reduced power conversion properties or increasing the size of the power converter. A new concept of such a machine features PM excitation, single-tooth winding and an additional circumferential excitation coil fixed on the stator in the axial center of the machine. By the appropriate feeding of this coil, the amplitude of the voltage effective excitation field can be varied from zero to values above those of the conventional PM-machines. The capability of reducing the excitation field to zero is an important safety aspect in case of failing of the feeding convertor.
Źródło:
Archives of Electrical Engineering; 2011, 60, 4; 531-540
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Armature MMF and electromagnetic performance analysis of dual three-phase 10-pole/24-slot permanent magnet synchronous machine
Autorzy:
Chen, Zhenfei
Xing, Ning
Ma, Hongzhong
Li, Zhixin
Li, Jiayu
Fan, Chenyang
Powiązania:
https://bibliotekanauki.pl/articles/2202550.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dual three-phase winding
fractional-slot
concentrated winding
permanent magnet synchronous machines (SCW-PMSMs)
MMF harmonic analysis
space harmonics
magnet eddy-current loss (ECL)
SVPWM voltage supply
Opis:
Fractional-slot concentrated-winding permanent magnet synchronous machines (FSCW-PMSMs) have a good prospect of application in the drive system of electric and hybrid electric vehicles. However, the armature magnetomotive force (MMF) of FSCWPMSM contains a large number of space harmonics, which induce large magnet eddycurrent loss (ECL). To solve this problem, a dual three-phase 10-pole and 24-slot winding layout is proposed.MMFharmonic analysis shows that the 1st, 7th and 17th space-harmonic winding factors of the proposed winding can be reduced by 100%, 87% and 87% respectively, compared with a dual three-phase 10-pole and 12-slot winding. Electromagnetic performances of the proposed machine under rated sinusoidal current supply and space vector pulse-width-modulated (SVPWM) voltage supply are investigated based on 2D finite-element analysis. It is shown that the proposed machine can meet the requirement of torque and efficiency in the full speed range. Especially, magnet ECL can be reduced greatly due to the reduction of the 7th and 17th space harmonics.
Źródło:
Archives of Electrical Engineering; 2023, 72, 1; 189--210
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies