Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fault diagnosis" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Fault diagnosis of analog circuit based on wavelet transform and neural network
Autorzy:
Wang, Hui
Powiązania:
https://bibliotekanauki.pl/articles/141368.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog circuit
fault diagnosis
neural network
wavelet transform
Opis:
Analog circuits need more effective fault diagnosis methods. In this study, the fault diagnosis method of analog circuits was studied. The fault feature vectors were extracted by a wavelet transform and then classified by a generalized regression neural network (GRNN). In order to improve the classification performance, a wolf pack algorithm (WPA) was used to optimize the GRNN, and a WPA-GRNN diagnosis algorithm was obtained. Then a simulation experiment was carried out taking a Sallen–Key bandpass filter as an example. It was found from the experimental results that the WPA could achieve the preset accuracy in the eighth iteration and had a good optimization effect. In the comparison between the GRNN, genetic algorithm (GA)-GRNN and WPA-GRNN, the WPA-GRNN had the highest diagnostic accuracy, and moreover it had high accuracy in diagnosing a single fault than multiple faults, short training time, smaller error, and an average accuracy rate of 91%. The experimental results prove the effectiveness of the WPA-GRNN in fault diagnosis of analog circuits, which can make some contributions to the further development of the fault diagnosis of analog circuits.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 175-185
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of single and multiple IGBTs open-circuit faults in a field-oriented controlled induction motor drive
Autorzy:
Sobański, P.
Orłowska-Kowalska, T.
Powiązania:
https://bibliotekanauki.pl/articles/140648.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motor
field-oriented control
condition monitoring
open-circuit
fault
fault diagnosis
Opis:
In this paper a transistor open-circuit fault diagnosis method in a rotor field oriented controlled induction motor drive, fed by a two-level voltage inverter has been proposed. The diagnostic procedure ensures detection and localization of single or multiple power switch failures in time shorter than one period of a stator current fundamental harmonic, without regard to a drive operation point. A new simple scheme of the diagnostic system is proposed. In order to validate the proposed transistor fault diagnostic method, a detailed simulation as well as experimental tests of the field-oriented control drive system were carried out and some of them are shown in this paper.
Źródło:
Archives of Electrical Engineering; 2017, 66, 1; 89-104
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on operation fault diagnosis algorithm of power grid equipment based on power big data
Autorzy:
Qian, Jianguo
Zhu, Bingquan
Li, Ying
Shi, Zhengchai
Powiązania:
https://bibliotekanauki.pl/articles/949910.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
association rules
big data
data mining
fault diagnosis
grid equipment
Opis:
Power big data contains a lot of information related to equipment fault. The analysis and processing of power big data can realize fault diagnosis. This study mainly analyzed the application of association rules in power big data processing. Firstly, the association rules and the Apriori algorithm were introduced. Then, aiming at the shortage of the Apriori algorithm, an IM-Apriori algorithm was designed, and a simulation experiment was carried out. The results showed that the IM-Apriori algorithm had a significant advantage over the Apriori algorithm in the running time. When the number of transactions was 100 000, the running of the IM-Apriori algorithm was 38.42% faster than that of the Apriori algorithm. The IM-Apriori algorithm was little affected by the value of supportmin. Compared with the Extreme Learning Machine (ELM), the IM-Apriori algorithm had better accuracy. The experimental results show the effectiveness of the IM-Apriori algorithm in fault diagnosis, and it can be further promoted and applied in power grid equipment.
Źródło:
Archives of Electrical Engineering; 2020, 69, 4; 793-800
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault-tolerant control for three-phase three-level T-type inverters with a redundant leg
Autorzy:
Chen, Danjiang
Zheng, Liyuan
Powiązania:
https://bibliotekanauki.pl/articles/2172799.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault diagnosis
fault-tolerant control
open-circuit fault
phase-leg fault
redundant leg
T-type inverter
Opis:
Three-level T-type inverters have lower total harmonic distortion in output voltage, higher power density and lower voltage stress of power switches compared with conventional two-level inverters and have been widely used in applications with a wide-power range. Reliability improvement is particularly important for the T-type inverters because of the increased number of power switches and high system complexity. This paper proposes a fault-tolerant topology, which is constructed by adding a redundant leg including halfbridge switches and neutral-point switches connected between the DC bus capacitors and the DC-link midpoint of the conventional T-type inverter. In addition, an after-fault control strategy is proposed based on the results of a fault diagnosis method using bridge voltage. The fault-tolerant control of the open-circuit fault of the power switches and the phase-leg fault can both be achieved by the proposed method. Experimental results are given to verify that the proposed fault-tolerant three-level T-type inverter can output the full voltage level and power during the fault-tolerant operation based on the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 931--948
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of an open-switch fault detection algorithm for a three-phase interleaved DC–DC boost converter in a photovoltaic system
Autorzy:
Boudjellal, Bilal
Benslimane, Tara
Powiązania:
https://bibliotekanauki.pl/articles/27309944.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
DC–DC converters
fault diagnosis
interleaved boost converter
open switch fault
photovoltaic (PV) system
Opis:
This paper presents a novel fault detection algorithm for a three-phase interleaved DC–DC boost converter integrated in a photovoltaic system. Interleaved DC–DC converters have been used widely due to their advantages in terms of efficiency, ripple reductions, modularity and small filter components. The fault detection algorithm depends on the input current waveform as a fault indicator and does not require any additional sensors in the system. To guarantee service continuity, a fault tolerant topology is achieved by connecting a redundant switch to the interleaved converter. The proposed fault detection algorithm is validated under different scenarios by the obtained results.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 661--676
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis of power transformer based on improved particle swarm optimization OS-ELM
Autorzy:
Li, Yuancheng
Ma, Longqiang
Powiązania:
https://bibliotekanauki.pl/articles/140428.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
fault diagnosis
improved particle swarm optimization
OS-ELM
parameter optimization
Opis:
A transformer is an important part of power transmission and transformation equipment. Once a fault occurs, it may cause a large-scale power outage. The safety of the transformer is related to the safe and stable operation of the power system. Aiming at the problem that the diagnosis result of transformer fault diagnosis method is not ideal and the model is unstable, a transformer fault diagnosis model based on improved particle swarm optimization online sequence extreme learning machine (IPSO-OS-ELM) algorithm is proposed. The improved particle swarmoptimization algorithm is applied to the transformer fault diagnosis model based on the OS-ELM, and the problems of randomly selecting parameters in the hidden layer of the OS-ELM and its network output not stable enough, are solved by optimization. Finally, the effectiveness of the improved fault diagnosis model in improving the accuracy is verified by simulation experiments.
Źródło:
Archives of Electrical Engineering; 2019, 68, 1; 161-172
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A hybrid active fault-tolerant control scheme for wind energy conversion system based on permanent magnet synchronous generator
Autorzy:
Tahri, A.
Hassaine, S.
Moreau, S.
Powiązania:
https://bibliotekanauki.pl/articles/140788.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wind energy conversion system
active fault-tolerant control
permanent magnet synchronous generator
sensor fault diagnosis
sliding mode observer
Opis:
Wind energy has achieved prominence in renewable energy production. There- fore, it is necessary to develop a diagnosis system and fault-tolerant control to protect the system and to prevent unscheduled shutdowns. The presented study aims to provide an experimental analysis of a speed sensor fault by hybrid active fault-tolerant control (AFTC) for a wind energy conversion system (WECS) based on a permanent magnet synchronous generator (PMSG). The hybrid AFTC switches between a traditional controller based on proportional integral (PI) controllers under normal conditions and a robust backstepping controller system without a speed sensor to avoid any deterioration caused by the sensor fault. A sliding mode observer is used to estimate the PMSG rotor position. The proposed controller architecture can be designed for performance and robustness separately. Finally, the proposed methodwas successfully tested in an experimental set up using a dSPACE 1104 platform. In this experimental system, the wind turbine with a generator connection via a mechanical gear is emulated by a PMSM engine with controled speed through a voltage inverter. The obtained experimental results show clearly that the proposed method is able to guarantee service production continuity for the WECS in adequate transition.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 485--497
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Main inductances of induction motor for diagnostically specialized mathematical models
Autorzy:
Węgiel, T.
Weinreb, K.
Sułowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/141392.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
silnik indukcyjny
uszkodzenie wirnika
diagnostyka
ekscentryczność wirnika
wirnik
induction motors
rotor fault diagnosis
rotor eccentricity
Opis:
In the paper modeling of main inductances for mathematical models of induction motors is applied to study the effects caused by a rotor eccentricity and saturation effects. All three possible types of eccentricity: static, dynamic and mixed are modeled. The most important parameters describing rotor eccentricity include self and mutual inductances of the windings. The structural changes of the permeance function as a result of eccentricity appearance and the Fourier spectra of inductances in occurrence of saturation for each case are determined in the paper. The presented algorithm can be used for the diagnostically specialized models of induction motors.
Źródło:
Archives of Electrical Engineering; 2010, 59, 1-2; 51-66
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis of T-type three-level inverter based on bridge voltages
Autorzy:
Chen, Danjiang
Liu, Yutian
Zhang, Shaozhong
Powiązania:
https://bibliotekanauki.pl/articles/1841372.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bridge voltage
fault diagnosis
fault signal
open-circuit fault
T-type three-level inverter
napięcie mostka
błędna diagnoza
sygnał błędu
błąd obwodu otwartego
falownik trójpoziomowy typu T
Opis:
Multilevel inverters have been widely used in various occasions due to their advantages such as low harmonic content of the output waveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, anda diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when anopen-circuit fault of the device occurred, and the effect on the circuit switching states andthe bridge voltages were analyzed. Then comprehensively considered the bridge voltages,and proposed a fault diagnosis method for a T-type three-level inverter based on specificfault diagnosis signals. Finally, the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of theinverter device, and has the advantage of being easy to implement.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 73-87
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Open-circuit fault diagnosis in three-phase induction motor using model-based technique
Autorzy:
Aswad, Raya A. K.
Jassim, Bassim M. H.
Powiązania:
https://bibliotekanauki.pl/articles/949900.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motor
model-based diagnosis
number of turns
open-circuit fault
Opis:
The presence of an open-circuit fault subjects a three-phase induction motor to severely unbalanced voltages that may damage the stator windings consecutively causing total shutdown of systems. Unplanned downtime is very costly. Therefore, fault diagnosis is essential for making a predictive plan for maintenance and saving the required time and cost. This paper presents a model-based diagnosis technique for diagnosing an open-circuit fault in any phase of a three-phase induction motor. The proposed strategy requires only current signals from the faulty machine to compare them with the healthy currents from an induction motor model. Then the errors of comparison are used as an objective function for a genetic algorithm that estimates the parameters of a healthy model, which they employed to identify and localize the fault. The simulation results illustrate the behaviours of basic parameters (stator and rotor resistances, self-inductances, and mutual inductance) and the number of stator winding turn parameters with respect to the location of an open-circuit fault. The results confirm that the number of stator winding turns are the useful parameters and can be utilized as an identifier for an open-circuit fault. The originality of this work is in extracting fault diagnosis features from the variations of the number of stator winding turns.
Źródło:
Archives of Electrical Engineering; 2020, 69, 4; 815-827
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies