Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "POWER" wg kryterium: Temat


Tytuł:
One phase active filter with energy storage for active power surge compensation in feed line
Autorzy:
Sowa, K.
Baszyński, M.
Piróg, S.
Powiązania:
https://bibliotekanauki.pl/articles/141248.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
active power filter
power surge compensation
Opis:
The paper presents a concept of an active filter with energy storage. This solution can be used for the compensation of momentary one phase high power loads with discontinued power consumption (e.g. spot welding machines). Apart from the typical filtering capabilities, the system’s task is also the continuity of the input power from the feeder line and limiting its fluctuation. The proposed by the author’s solution can produce measurable economic benefits by reducing the rated power necessary to energize periodically operating loads and improving the indicators of electrical energy quality. The developed method of active power surges compensation enables a flexible approach to requirements concerning the rated power of the point to which the periodically operating loads with high peak current value are connected. The tests were conducted on a simulation model specially developed in Matlab & Simulink environment, proving high effectiveness of the presented solution.
Źródło:
Archives of Electrical Engineering; 2016, 65, 2; 221-234
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shunt power electronic buffer as active filter and energy flow controller
Autorzy:
Szromba, A.
Powiązania:
https://bibliotekanauki.pl/articles/141224.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
active current
power control
power quality
Opis:
The considered shunt active power filter can be controlled not only to compensate non-active current in the supply source, but additionally to optimize energy flow between the source and the load. In such a case the filter shapes the source current to be active and simultaneously regulates its magnitude. The presented filter/buffer can operate properly even when the load contains AC or DC variable energy source of any characteristic. The device can optimize energy flow for a single load, but also for a group of loads as well. The distinctive feature of the employed control method of the filter/buffer is that certain changes of energy stored in the device are utilized as the source of information concerning the active current of the load. This control method is very flexible and can be implemented to nearly all structures of active filters, for DC, single- and multiphase circuits.
Źródło:
Archives of Electrical Engineering; 2013, 62, 1; 55-75
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of transient states in the start-up path during voltage and start-up power application
Autorzy:
Grządzielski, Ireneusz
Olejnik, Bartosz
Zakrzewski, Mikołaj
Powiązania:
https://bibliotekanauki.pl/articles/949916.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
blackout
electric power system
restoration power
Opis:
During a blackout, after the post-disaster collapse of an electric power system (EPS), units of thermal power plants should switch-over to the house load operation mode (PPW). However, regarding the dynamics of a post-disaster blackout process, many units can be in forced outage Therefore, restart of these units from the start-up sources with a self-start capability is necessary. The Transmission Network Code in force imposes periodic tests and system tests for such sources. Any system test must be preceded and followed by simulation investigations in which the possibilities: (1) to bring voltage to the started-up power plant by a starting path and (2) to activate the highest-power auxiliaries (PW) of the unit being started-up are evaluated. In the paper, chosen results of simulative investigations of the transient phenomena in the starting path from the hydroelectric power plant of Włocławek (HPP Włocławek) to the thermal power plant of Pątnów (w (TPP Pątnów), related to the system test conducted in September 2017 have been presented.
Źródło:
Archives of Electrical Engineering; 2019, 68, 4; 749-769
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A power constraint index to rank and group critical contingencies based on sensitivity factors
Autorzy:
Arenas-Crespo, O.
Candelo, J. E.
Powiązania:
https://bibliotekanauki.pl/articles/141453.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
contingency ranking
critical contingencies
power system operation
power system planning
sensitivity power factors
Opis:
Finding the most critical contingencies in a power system is a difficult task as multiple evaluations of load and generation scenarios are needed. This paper presents a mathematical formulation for selecting, ranking, and grouping the most critical N-1 net- work contingencies, based on the calculation of a Power Constraint Index (PCI) obtained from the Outage Transfer Distribution Factors (OTDF). The results show that the PCI is only affected by the impedance parameter of the transmission network, the topology, and the location of all generators. Other methods, such as the Performance Index (PI) and the Overload Index (OL) are affected by the power generation and demand variations. The proposed mathematical formulation can be useful to accelerate the calculation of other methods that evaluate contingencies in power system planning and operation. Furthermore, the fast calculation of indices makes it suitable for online evaluation and classification of multiple events considering the current topology. The results showed that the proposed algorithm easily selected and ranked the expected contingencies, with the highest values of the index corresponding to the most critical events. In the filtering process, the computational calculation time improved without losing the robustness of the results.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 247--261
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power supply risk assessment method for relay protection system faults
Autorzy:
Tuyou, S.
Jiekang, W.
Weideng, Y.
Anan, D.
Powiązania:
https://bibliotekanauki.pl/articles/141134.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
reduced power supply load power
relay protection systems
risk value
power supply risk assessment
Opis:
The influence and the potential risk due to hidden faults of a relay protection system on power supply in distribution systems are paid more and more attention to. A probability analysis method is used to analyse fault characteristics and action mechanism of dominant faults, hidden misoperation and non-operation of the relay protection systems, and failure probability model of relay protection system is constructed and simplified. The effects of dominant faults, hidden misoperation and non-operation of the relay protection systems on the reduced power supply load power are analysed, and a probabilistic model for reduced power supply load power is constructed by three parts corresponding to dominant faults, hidden misoperation and non-operation. A probability calculation method of power supply risk occurrence due to hidden faults of relay protecttion system is proposed considering the fault probability of the relay protection systems, the frequency of the hidden faults occurring in operation period, the reduced power supply load power or load power outage, and the connection mode of the in-lines, out-lines and transformers in a substation. The feasibility and applicability of the proposed method for estimation of risk value probability of the relay protection systems is verified by two studied examples.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 803-814
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical analysis and dimensioning of a wind farm energy storage system
Autorzy:
Waśkowicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/141698.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy storage
power quality
renewable energy
wind power
Opis:
The growth in renewable power generation and more strict local regulations regarding power quality indices will make it necessary to use energy storage systems with renewable power plants in the near future. The capacity of storage systems can be determined using different methods most of which can be divided into either deterministic or stochastic. Deterministic methods are often complicated with numerous parameters and complex models for long term prediction often incorporating meteorological data. Stochastic methods use statistics for ESS (Energy Storage System) sizing, which is somewhat intuitive for dealing with the random element of wind speed variation. The proposed method in this paper performs stabilization of output power at one minute intervals to reduce the negative influence of the wind farm on the power grid in order to meet local regulations. This paper shows the process of sizing the ESS for two selected wind farms, based on their levels of variation in generated power and also, for each, how the negative influences on the power grid in the form of voltage variation and a shortterm flicker factor are decreased.
Źródło:
Archives of Electrical Engineering; 2017, 66, 2; 265-277
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected methods for improving operating conditionsof three-phase systems working in the presenceof current and voltage deformation – part II
Autorzy:
Pasko, M.
Buła, D.
Dębowski, K.
Grabowski, D.
Maciążek, M.
Powiązania:
https://bibliotekanauki.pl/articles/141598.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filters
compensation of higher harmonics
hybrid active power filters
power quality
symmetrisation
Opis:
The paper includes a summary of long-time research conducted by a research team in the Institute of Electrical Engineering and Computer Science at Silesian University of Technology. The research work has principally been related to selected problems in the field of analysis and synthesis of systems aimed at symmetrisation and improvement of some power quality parameters. This paper constitutes the second part of the report on the research. It has been devoted to three-phase system symmetrisation as well as effective elimination of higher harmonics and substantial improvement of power quality by means of hybrid active power filters.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 603--616
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proposal of a regional grid cluster model for analysis of electrical power network performance
Autorzy:
Li, Yang
Janik, Przemysław
Schwartz, Harald
Pfeiffer, Klaus
Powiązania:
https://bibliotekanauki.pl/articles/2135739.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
decentralized generation
grid cluster
power balance
regional power grid
Opis:
This paper provides a method for simplified description of a regional power grid model aimed to deliver a grid reduction, and improve grid performance observability. The derived power grid model can be used to analyze the regional allocation of the decentralized energy generation and consumption. The expansion of wind and solar generation in the power system affects the residual load. The power balance between electricity consumption and generation was calculated and analyzed based on the temporal and spatial scales. The proposed grid clustering method is a useful approach for performance analysis in systems with a growing share of renewable generation.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 601--613
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Induced sheath voltages in 110 kV power cables – case study
Autorzy:
Czapp, S.
Dobrzyński, K.
Klucznik, J.
Lubośny, Z.
Powiązania:
https://bibliotekanauki.pl/articles/140786.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electric shock hazard
induced voltages
power cables
power system
Opis:
This paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse various configurations of the metallic cable sheaths bonding and earthing (singlepoint bonding, both-ends bonding, cross-bonding) and their impact on induced voltages in the cable sheaths. The analysis presented in the paper shows, that it is possible to find an optimal configuration of the complicated power cable system, in terms of electric shock hazard, maximal power transfer as well as economic aspects.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 361-370
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robust design of power system stabilizer using bacterial foraging algorithm
Autorzy:
Abdul Hameed, K.
Palani, S.
Powiązania:
https://bibliotekanauki.pl/articles/141194.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bacterial foraging algorithm
power system stabilizer
power system stability
Opis:
In this paper, a novel bacterial foraging algorithm (BFA) based approach for robust and optimal design of PID controller connected to power system stabilizer (PSS) is proposed for damping low frequency power oscillations of a single machine infinite bus bar (SMIB) power system. This paper attempts to optimize three parameters (Kp, Ki, Kd) of PID-PSS based on foraging behaviour of Escherichia coli bacteria in human intestine. The problem of robustly selecting the parameters of the power system stabilizer is converted to an optimization problem which is solved by a bacterial foraging algorithm with a carefully selected objective function. The eigenvalue analysis and the simulation results obtained for internal and external disturbances for a wide range of operating conditions show the effectiveness and robustness of the proposed BFAPSS. Further, the time domain simulation results when compared with those obtained using conventional PSS and Genetic Algorithm (GA) based PSS show the superiority of the proposed design.
Źródło:
Archives of Electrical Engineering; 2013, 62, 1; 141-152
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement-based harmonic current modeling of mobile storage for power quality study in the distribution system
Autorzy:
Wenge, C.
Guo, H.
Roehrig, C.
Powiązania:
https://bibliotekanauki.pl/articles/140847.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical vehicle
harmonic load modeling
harmonic measurement in power system
power quality
power system harmonics
Opis:
Electric vehicles (EVs) can be utilized as mobile storages in a power system. The use of battery chargers can cause current harmonics in the supplied AC system. In order to analyze the impact of different EVs with regardto their number and their emission of current harmonics, a generic harmonic current model of EV types was built and implemented in the power system simulation tool PSS®NETOMAC. Based on the measurement data for different types of EVs three standardized harmonic EV models were developed and parametrized. Further, the identified harmonic models are used by the computation of load flow in a modeled, German power distribution system. As a benchmark, a case scenario was studied regarding a high market penetration of EVs in the year 2030 for Germany. The impact of the EV charging on the power distribution system was analyzed and evaluated with valid power quality standards.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 801-814
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The risk of large blackout failures in power systems
Autorzy:
Sroka, Krzysztof
Złotecka, Daria
Powiązania:
https://bibliotekanauki.pl/articles/141708.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
blackout
power deficit
power system
risk assessment
extraordinary events
Opis:
The paper concerns the assessment of blackout hazards in the power systems. On the basis of statistical data from more than one hundred failures in power systems that affected the world in the last fifty years, the analysis was carried out regarding the number of people affected by a blackout, power losses in the system, duration of a failure and its direct causes. The paper also describes the methodology of risk analysis and vulnerability analysis of the extraordinary events occurrence in electrical power systems resulting in failures. The structure of risk analysis was based on the bow tie model, identifying threats, unwanted events, barriers and consequences of a system failure. Moreover, particular attention was drawn to the impact of the power reserve deficit in the Polish Power System in the coming years on the increase in the risk of a blackout failure.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 411-426
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A control topology for frequency regulation capability in a grid integrated PV system
Autorzy:
Kumar, Ritesh
Sahu, Balakrushna
Shiva, Chandan Kumar
Rajender, B.
Powiązania:
https://bibliotekanauki.pl/articles/140902.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
frequency controller
maximum power point tracking (MPPT)
photovoltaic (PV)
power system
pseudo maximum power point tracking (PMPPT)
Opis:
Photovoltaic (PV) cells are very costly because of the silicon element which is not cheaply available. Usually, PV cells are preferred to be used at maximum efficiency. Therefore, PV plants are emphasized to extract maximum power from PV cells. When inertia free PV plants are integrated into the grid in large numbers, the problem of maintaining system stability subjected to load perturbation is quite difficult. In response to this, a control topology is being an approach to make available the PV cells in maintaining system stability by utilizing the system frequency deviation as feedback to the controller. To implement this, the PVs are operated at Maximum Power Point Tracking (MPPT). This allows the PV to operate at Pseudo Maximum Power Point tracking (PMPPT) which makes it possible to run the PV with reserve power capacity without employing a battery for storage. The control strategy has been implemented over a two-stage power conversion model of the PV system. The simulation results showed that the proposed control PMPPT topology is effective in frequency regulation capability as compared to the MPPT technique.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 389-401
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New approaches for the identification of influential and critical nodes in an electric grid
Autorzy:
Adebayo, Isaiah
Sun, Yanxia
Powiązania:
https://bibliotekanauki.pl/articles/2135727.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
centrality measures
critical nodes
influential nodes
power flow
power system
Opis:
The aftermath of including new technologies in a modern electric system in conjunction with the incessant rise in power demand could pose a risk to the optimal operation of the system. Therefore, it becomes imperative to identify the most influential and critical nodes of such a system to avert future problems in network operation. In this paper, to identify most significant nodes of the system, the authors propose two measures of centrality in accordance with the network structural properties of a power system, namely, degree centrality (DC) and eigenvector centrality (EC). These are expressed considering the admittance matrix that exists among the interconnection of load to load nodes in an electrical power network. A critical node closeness centrality (CNCC) method is also proposed to identify critical nodes of the system. This is done by modifying the conventional closeness centrality (CC) to include the influence of interconnection that exists between network load to load nodes as captured by the admittance matrix between them. A comparative analysis of the proposed techniques with other conventional methods is also carried out. The result of the simulation shows that the proposed methods could serve as alternative tools in the identification of influential and weak nodes in a power system.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 671--686
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active power decoupling topology for AC-DC and DC-AC single-phase systems with decoupling capacitor minimization
Autorzy:
Stawiarski, Ł.
Piróg, S.
Powiązania:
https://bibliotekanauki.pl/articles/141750.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power decoupling
capacitance reduction
microgrid converter
double-line frequency ripple power
single-phase systems
power factor correction
Opis:
Passive power decoupling in single-phase DC-AC and AC-DC systems usually requires usage of electrolytic capacitors. To minimize converter volume, increase reliability, robustness and to eliminate ripple power effect on the DC side, new solutions for Active Power Decoupling are proposed. In this paper a novel Active Power Decoupling topology for low power single-phase AC-DC and DC-AC converters is presented. The proposed topology is based on well-known boost and buck-boost topologies but with a completely different control scheme. The topology description with a complete control algorithm is presented. The proposed APD solution is verified by experimental results of a 450 W converter in AC-DC mode and a 320 W converter in DC-AC mode.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 193-205
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies