Tytuł:
Load regulation application of university campus based on solar power generation forecasting
Autorzy:
Han, Guozheng
Tan, Shujuan
Zhang, Zihan
Powiązania:
https://bibliotekanauki.pl/articles/24202744.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
load regulation
solar power generation forecast
photovoltaic generation
Opis:
For a solar photovoltaic power system on a university campus, the electricity generated by the system meets the campus load, and the extra electricity is delivered to the grid. Generally, the price of the photovoltaic system is cheaper than that of the utility power system. The full use of solar electricity can reduce the electricity cost of the school. The deep belief network is used to predict solar photovoltaic generation and electricity load, and the gap is found. According to the gap, the power loads on the campus are adjusted to improve the utilization rate of solar power generation. Through the practical application of Changqing Campus of Qilu University of Technology in China, it is found that the utilization rate of solar photovoltaic power generation effectively improved from 91.24% in 2017 to 98.16% in 2019, and the annual electricity is saved by 68 610 yuan (in 2019).
Źródło:
Archives of Electrical Engineering; 2023, 72, 2; 429--441
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electric power steering system controller design using induction machine
Autorzy:
Naibiao, Zhang
Tianfang, Cai
Xuezheng, Han
Powiązania:
https://bibliotekanauki.pl/articles/141715.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
motor induction
electric power
PID control
EPS
Opis:
An electric power steering system (EPS) is a new type of steering system developed after a mechanical hydraulic power system (MHPS) and electric-hydraulic power steering system (EHPS). In order to coordinate and solve the portability and sensitivity of the steering system optimally, taking an induction power steering system as the research object, the control algorithm of induction motor control under the EPS is studied in this paper. In order to eliminate the feed-forward performance degradation caused by the change of feed-forward parameters, an on-line identification algorithm of feed-forward parameters is proposed. It can improve the control performance of online identification among three feed-forward parameters in the T-axle motor, it improves on the robustness of feed-forward control performance, at the same time it also gives simulation and test results. This method can improve the control performance of the three feed-forward parameter online identification of the T-axis motor and improve the robustness of feed-forward control performance. At the same time, simulation and test results are given. The simulation results show that the algorithm can significantly improve the response speed and control accuracy of EPS system control.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 279-293
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of control parameters on synchronization stability of virtual synchronous generator
Autorzy:
Zhang, Yanxia
Cheng, Yachao
Liu, Kaixiang
Han, Yue
Powiązania:
https://bibliotekanauki.pl/articles/2172794.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
control parameter
frequency modulation coefficient
phase plane method
synchronization stability
virtual synchronous generator
Opis:
Different from the synchronization mechanism of synchronous generators, the non-synchronous generators must be synchronized with the grid through a controller. Generally, the virtual synchronous generator (VSG) control strategy is adopted for this purpose. In view of the current situation, where the control loops are not comprehensively considered in the research of the synchronization stability of the VSG, this paper considers multiple control loops, such as active frequency loops, virtual governors, power filters and current constraint control, to establish the mathematical model of the VSG and infinite system. On this basis, the correlation formula between power angle difference and control parameters is deduced. Adopting the phase plane method, the influence of different control loops and their parameters on the transient synchronization stability is analyzed. Finally, a setting principle of the frequency modulation coefficient of virtual governors is proposed, which not only meets the response speed of control systems, but also has good control performance.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 811--828
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel combinational evaluation method of voltage and reactive power in regional power grid containing renewable energy
Autorzy:
Ji, Yuqi
Chen, Xuehan
Xiao, Han
Shi, Shaoyu
Kang, Jing
Wang, Jialin
Zhang, Shaofeng
Powiązania:
https://bibliotekanauki.pl/articles/1955201.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adaptive weighting coefficient
combinational evaluation
renewable energy
typical scenarios
adaptacyjny współczynnik wagowy
ocena kombinacyjna
energia odnawialna
typowy scenariusz
Opis:
The output of renewable energy is strongly uncertain and random, and the distribution of voltage and reactive power in regional power grids is changed with the access to large-scale renewable energy. In order to quantitatively evaluate the influence of renewable energy access on voltage and reactive power operation, a novel combinational evaluation method of voltage and reactive power in regional power grids containing renewable energy is proposed. Firstly, the actual operation data of renewable energy and load demand are clustered based on the K-means algorithm, and several typical scenarios are divided. Then, the entropy weight method (EWM) and the analytic hierarchy process (AHP) are combined to evaluate the voltage qualified rate, voltage fluctuation, power factor qualified rate and reactive power reserve in typical scenarios. Besides, the evaluation results are used as the training samples for back-propagation (BP) neural networks. The proposed combinational evaluation method can calculate the weight coefficient of the indexes adaptively with the change of samples, which simplifies the calculation process of the indexes’ weight. At last, the case simulation of an actual regional power grid is provided, and the historical data of one year is taken as the sample for training, evaluating and analyzing. And finally, the effectiveness of the proposed method is verified based on the comparison with the existing method. The evaluated results could provide reference and guidance to the operation analysis and planning of renewable energy.
Źródło:
Archives of Electrical Engineering; 2021, 70, 4; 925-942
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies