Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Fang, Yan" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Research on regional emergency DC power support strategy of VSC-MTDC transmission system
Autorzy:
Li, Congshan
Sheng, Tingyu
Fang, Yan
Li, Yikai
Powiązania:
https://bibliotekanauki.pl/articles/1841327.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coordinated control
dynamic active power support
emergency DC power support
VSC-MTDC
skoordynowana kontrola
dynamiczne wspomaganie mocy czynnej
awaryjne wsparcie zasilania prądem stałym
Opis:
In the asynchronous interconnected power grid that is composed of the multiterminal voltage-source converter high voltage direct current (VSC-MTDC) system, the control methods of each converter station and the frequency of the connected AC systemare not the same. When a fault occurs in any place of the asynchronous interconnected system, it will cause the system to have power shortage or surplus, affecting the safe and stable operation of the interconnected power grid. In order to solve the problem of insufficient regional active power reserve, based on the VSC-MTDC asynchronous regional interconnection system and the principle of regional sharing, the dynamic power controller under disturbance conditions is established, and the controller parameters are set to achieve the accuracy of unbalanced power in the disturbance area measuring. Then, according to the degree of the disturbance power, considering the factors that affect the support effect of the converter station, an emergency DC power support (EDCPS) scheme under different power disturbances is formulated to achieve power compensation for the disturbance area. Basedon PSCAD/EMTDC software, the proposed control strategy is simulated. The result showst hat the converter station closer to the disturbance area has a better support effect, and the dynamic active power controller can timely and accurately deliver to the disturbance area when the active power reserve is insufficient.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 145-160
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An approach to suppress low-frequency oscillation in the hybrid multi-Infeed HVDC of mixed H2/H∞ robust-based control theory
Autorzy:
Li, Congshan
Liu, Yan
Li, Yikai
He, Ping
Fang, Yan
Sheng, Tingyu
Powiązania:
https://bibliotekanauki.pl/articles/2042784.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additional damping controller
CSP
HMIDC
LFO
mixed 2/∞ control
TLS-ESPRIT
Opis:
A hybrid multi-infeed HVDC (HMIDC) system is composed of line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage-source converterbased high-voltage direct current (VSC-HVDC), whose receiving ends have electrical coupling. To solve the problem of low-frequency oscillation (LFO) caused by insufficient damping in the HMIDC system, according to the multi-objective mixed 2/∞ output feedback control theory with regional pole assignment, an additional robust damping controller is designed in this paper, which not only has good robustness, but also has strong adaptability to the change of system operation mode. In the paper, the related oscillation modes and transfer function of the controlled plant are obtained, which are identified by the total least squares estimation of signal parameters via rotary invariance technology (TLS-ESPRIT). In addition, the control-sensitive point (CSP) for suppressing LFO based on the small disturbance test method is determined, which is suitable for determining the installation position of the controller. The results show that the control sensitivity factor of VSC-HVDC is greater than that of LCC-HVDC so that adding an additional damping controller to VSC-HVDC is better than LCC-HVDC in suppressing the LFO of HMIDC. Finally, a hybrid double infeed DC transmission system with three receiving terminals is built on PSCAD/EMTDC where the time-domain simulations are performed to verify the correctness of the CSP selection and the effectiveness of the controller.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 109-124
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies