Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "PI controller" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Unified design method of time delayed PI controller for first order plus dead-time process models with different dead-time to time constant ratio
Autorzy:
Pathiran, Arun R.
Muniraj, R.
Iruthayarajan, M. Willjuice
Prabhu, S. R. Boselin
Jarin, T.
Powiązania:
https://bibliotekanauki.pl/articles/1409359.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PI controller
time delayed PI controller
dead-time compensation
Opis:
The time delay element present in the PI controller brings dead-time compensation capability and shows improved performance for dead-time processes. However, design of robust time delayed PI controller needs much responsiveness for uncertainty in dead-time processes. Hence in this paper, robustness of time delayed PI controller has been analyzed for First Order plus Dead-Time (FOPDT) process model. The process having dead-time greater than three times of time constant is very sensitive to dead-time variation. A first order filter is introduced to ensure robustness. Furthermore, integral time constant of time delayed PI controller is modified to attain better regulatory performance for the lag-dominant processes. The FOPDT process models are classified into dead-time/lag dominated on the basis of dead-time to time constant ratio. A unified tuning method is developed for processes with a number of dead-time to time constant ratio. Several simulation examples and experimental evaluation are exhibited to show the efficiency of the proposed unified tuning technique. The applicability to the process models other than FOPDT such as high-order, integrating, right half plane zero systems are also demonstrated via simulation examples.
Źródło:
Archives of Control Sciences; 2021, 31, 2; 447-476
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robust control system design in frequency domain
Autorzy:
Veselý, V
Osuský, J
Powiązania:
https://bibliotekanauki.pl/articles/964036.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hybrid control
equivalent subsystem method
PI controller
Opis:
In this paper two robust control methods for hybrid system are presented. Both methods are usefull for SISO and MIMO systems. Controller design procedure is developed in frequency domain. Equivalent subsystem method is used for controller design in this paper. Stability condition of proposed methods bases on small gain theory and uses additive and inverse additive model type. Two tank water system is presented in the paper and serves as a numerical example to compare effectiveness of described methods.
Źródło:
Archives of Control Sciences; 2013, 23, 1; 61-78
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of robust multi-loop PI controller for improved disturbance rejection with constraint on minimum singular value
Autorzy:
Arun, Pathiran
Muniraj, Rathinam
Boselin Prabhu, S.R.
Jarin, T.
Willjuice Iruthayarajan, M.
Powiązania:
https://bibliotekanauki.pl/articles/27324013.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
multi-loop PI controller
multivariable system
decentralized control
disturbance rejection
robust stability
Opis:
Disturbance rejection performance optimization with constraints on robustness for a multivariable process is commonly encountered in industrial control applications. This paper presents the tuning of a multi-loop Proportional Integral (PI) controller method to enhance the performance of load disturbance rejection using evolutionary optimization. The proposed design methodology is formulated to minimize the load disturbance rejection response and the input control energy under the constraints of robust stability. The minimum singular value of multiplicative uncertainty is considered a multi-loop system robust stability indicator. Optimization is performed to achieve the same, or higher level than the most-explored Direct Synthesis (DS) based multi-loop PI controller, which is derived from a conventional criterion. Simulation analysis clearly proved that the proposed multi-loop PI controller tuning method gives better disturbance rejection, and either, the same or a higher level of robust stability when compared to the DS-based multi-loop PI controller.
Źródło:
Archives of Control Sciences; 2023, 33, 4; 839--859
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of multiple-area renewable integrated hydro-thermal system considering artificial rabbit optimized PI (FOPD) cascade controller and redox flow battery
Autorzy:
Saha, Arindita
Chiranjeevi, Tirumalasetty
Devarapalli, Ramesh
Babu, Naladi Ram
Dash, Puja
Garcìa Màrquez, Fausto Pedro
Powiązania:
https://bibliotekanauki.pl/articles/27324511.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
solar thermal
automatic generation control
geothermal
artificial rabbit optimization
redox flow battery
PI(FOPD) controller
Opis:
The current task explores automatic generation control knowledge under old-style circumstances for a triple-arena scheme. Sources in area-1 are thermal-solar thermal (ST); thermalgeothermal power plant (GPP) in area-2 and thermal-hydro in area-3. An original endeavour has been set out to execute a new performance index named hybrid peak area integral squared error (HPA-ISE) and two-stage controller with amalgamation of proportional-integral and fractional order proportional-derivative, hence named as PI(FOPD). The performance of PI(FOPD) has been compared with varied controllers like proportional-integral (PI), proportional-integralderivative (PID). Various investigation express excellency of PI(FOPD) controller over other controller from outlook regarding lessened level of peak anomalies and time duration for settling. Thus, PI(FOPD) controller’s excellent performance is stated when comparison is undergone for a three-area basic thermal system. The above said controller’s gains and related parameters are developed by the aid of Artificial Rabbit Optimization (ARO). Also, studies with HPA-ISE enhances system dynamics over ISE. Moreover, a study on various area capacity ratios (ACR) suggests that high ACR shows better dynamics. The basic thermal system is united with renewable sources ST in area-1 also GPP in area-2. Also, hydro unit is installed in area-3. The performance of this new combination of system is compared with the basic thermal system using PI(FOPD) controller. It is detected that dynamic presentation of new system is improved. Action in existence of redox flow battery is also examined which provides with noteworthy outcome. PI(FOPD) parameters values at nominal condition are appropriate for higher value of disturbance without need for optimization.
Źródło:
Archives of Control Sciences; 2023, 33, 4; 861--884
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies