Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "high-frequency" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
On the Noise Hazard Assessment within the Intermediate Range of the High Audible and the Low Ultrasonic Frequencies
Autorzy:
Śliwiński, A.
Powiązania:
https://bibliotekanauki.pl/articles/177315.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic noise assessment
high frequency audiometry
Opis:
In parallel to the ultrasonic noise assessment procedures and research activity in the field there have appeared several papers in the domain of so called high-frequency audiometry which covers the range of frequencies 8–20 kHz. They are important for recognizing the harmfulness and hazard of the audible high frequency sound components in the same range as the one of the low frequency ultrasonic noise. On the other hand there exists a certain inconsequent situation in the general approach to the problem of ultrasonic noise hazard assessment in work places environment which concerns the convention to include the frequency range of 10–20 kHz to the domain of ultrasonics. The range consists of one third octave bands of central frequencies: 10, 12.5, 16, 20 kHz and conventionally is called low frequency ultrasonic noise though at least the components of the two lowest bands are naturally audible by a majority of population (mainly young people).The paper presents a discussion related to some achievements of the two domains and some conclusions which could be useful for a more consequent description of the subject and could be taken into account in the future regulations for the ultrasonic noise assessment in work places environment.
Źródło:
Archives of Acoustics; 2016, 41, 2; 331-338
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Extended High Frequency Hearing Thresholds in Tinnitus Patients with Normal Hearing
Autorzy:
Ristovska, Lidija
Jachova, Zora
Powiązania:
https://bibliotekanauki.pl/articles/31339952.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
extended high frequency
hearing loss
tinnitus
Opis:
The aim of the study was to compare the extended high-frequency (EHF) hearing thresholds (10–16 kHz) in tinnitus and non-tinnitus ears, in a group of 98 patients with unilateral tinnitus and normal hearing at standard audiometric frequencies, in a 0.125–8 kHz range. It was found that a total of 65 patients (66%) had a hearing loss (a threshold shift >20 dB HL) in the EHF range and the EHF hearing loss occurred more frequently in the tinnitus ear than in the non-tinnitus ear. The data also indicate that the EHF thresholds increased with the patient’s age and were in most patients higher in the tinnitus ear than in the non-tinnitus ear.
Źródło:
Archives of Acoustics; 2022, 47, 4; 449-455
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Study of Identifying Emission Sources of Acoustic Signals on the Cylinder Body of a Two-Stroke Marine Diesel Engine
Autorzy:
Dong, Xuan Thin
Nguyen, Manh Hung
Powiązania:
https://bibliotekanauki.pl/articles/1953513.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission
two-stroke marine diesel engine
experimental method
low-to-high frequency ranges
medium-to-high frequency ranges
vibration
Opis:
In this paper, an experimental method was utilized to investigate acoustic emission (AE) characteristics and to identify emission sources of the nonlinear AE signal on the cylinder body of a large low-speed two-stroke marine diesel engine in real-working conditions on the sea in misfiring and normal firing modes. Measurements focused on the AE signal acquired in a transverse direction in low-frequency (20-80 kHz), medium-frequency (100-400 kHz) and high-frequency (400-900 kHz) ranges. The collected signals were analyzed on the crank angle and crank angle-frequency domains. The results showed that all potential sources of the nonlinear AE signal could be mapped in the low-frequency range. However, only the AE signal caused by the combustion process at around the top dead center could be well-observed in the medium-to-high-frequency range. The findings also revealed that in normal firing conditions, the AE energy radiated by friction in the down-stroke period was smaller than in the up-stroke process due to gas-sealing forces. Moreover, the AE energy in the misfiring condition was higher than in the normal firing state. These outcomes considerably contributed understandings to characteristics of friction and wear around the mid-stroke area of the cylinder on a two-stroke marine diesel engine.
Źródło:
Archives of Acoustics; 2021, 46, 1; 105-119
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thick Film Transducers for High Frequency Coded Ultrasonography
Autorzy:
Nowicki, A.
Lewandowski, M.
Wójcik, J.
Tymkiewicz, R.
Lou-Moller, R.
Wolny, W.
Zawada, T.
Powiązania:
https://bibliotekanauki.pl/articles/176939.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
transducers
thick film
high frequency ultrasound
pulse compression
Golay codes
Opis:
Recently a new technology of piezoelectric transducers based on PZT thick film has been developed as a response to a call for devices working at higher frequencies suitable for production in large numbers at low cost. Eight PZT thick film based focused transducers with resonant frequency close to 40 MHz were fabricated and experimentally investigated. The PZT thick films were deposited on acoustically engineered ceramic substrates by pad printing. Considering high frequency and nonlinear propagation it has been decided to evaluate the axial pressure field emitted (and reflected by thick metal plate) by each of concave transducer differing in radius of curvature – 11 mm, 12 mm, 15 mm, 16 mm. All transducers were activated using AVTEC AVG-3A-PS transmitter and Ritec diplexer connected directly to Agilent 54641D oscilloscope. As anticipated, in all cases the focal distance was up to 10% closer to the transducer face than the one related to the curvature radius. Axial pressure distributions were also compared to the calculated ones (with the experimentally determined boundary conditions) using the angular spectrum method including nonlinear propagation in water. The computed results are in a very good agreement with the experimental ones. The trans- ducers were excited with Golay coded sequences at 35–40 MHz. Introducing the coded excitation allowed replacing the short-burst transmission at 20 MHz with the same peak amplitude pressure, but with almost double center frequency, resulting in considerably better axial resolution. The thick films exhibited at least 30% bandwidth broadening comparing to the standard PZ 27 transducer, resulting in an increase in matching filtering output by a factor of 1.4–1.5 and finally resulting in a SNR gain of the same order.
Źródło:
Archives of Acoustics; 2011, 36, 4; 945-954
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tinnitus Therapy Based on High-Frequency Linearization Principles - Preliminary Results
Autorzy:
Poremski, T.
Kostek, B.
Powiązania:
https://bibliotekanauki.pl/articles/177726.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tinnitus
sensorineural hearing loss
tinnitus masking
Tinnitus Retraining Therapy (TRT)
signal quantization
dithering technique
high-frequency linearization
ultrasound dither noise
Opis:
The aim of this work is to present problems related to tinnitus symptoms, its pathogenesis, hypothe- ses on tinnitus causes, and therapy treatment to reduce or mask the phantom noise. In addition, the hypothesis on the existence of parasitic quantization that accompanies hearing loss has been recalled. Moreover, the paper describes a study carried out by the Authors with the application of high-frequency dither having specially formed spectral characteristics. Discussion on preliminary results obtained and conclusions are also contained.
Źródło:
Archives of Acoustics; 2012, 37, 2; 161-170
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing Status in Young People Using Portable Audio Players
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Zaborowski, K.
Zamojska-Daniszewska, M.
Rutkowska-Kaczmarek, P.
Dudarewicz, A.
Śliwinska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/176501.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
portable audio players
PAPs
pure-tone audiometry
transient-evoked otoacoustic emissions
TEOAEs
hearing threshold levels
high-frequency notches
noise-induced hearing loss
Opis:
The aim of this study was to evaluate the hearing status in young adults using portable audio players (PAPs) in relation to their listening habits. The study included 58 subjects, aged 22.8±2.8 years, non-occupationally exposed to noise. Questionnaire inquiry aimed at collecting personal data, the information on PAPs usage habits, self-assessment of hearing status and identification of risk factors for noise-induced hearing loss (NIHL) were performed in study subjects. Hearing tests included pure-tone audiometry (PTA) and transient-evoked optoacoustic emission (TEOAE). All subjects were PAPs users. Depending on listening habits they were divided into the subgroups of “frequent” users (>1 h/day) and “non-frequent” users (≤1 h/day). There were no significant differences between subgroups in prevalence of NIHL risk factors and self-assessment of hearing status. However, frequent users more often complained of tinnitus and hyperacusis. Majority (81.9 %) of participants had normal hearing. Nevertheless, 6.9 % of audiograms showed high-frequency notches typical for NIHL. Both, the PTA and TEOAE indicated worse hearing in non-frequent users compared to frequent users. No significant differences in prevalence of high-frequency notches between subgroups were noted. The outcomes do not support some previous studies results that the excessive exposure to music listened through PAPs might result in accelerating of development of NIHL loss in young adults.
Źródło:
Archives of Acoustics; 2017, 42, 1; 113-120
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies