Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "beamforming" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Multi-Element Synthetic Transmit Aperture in Medical Ultrasound Imaging
Autorzy:
Trots, I.
Nowicki, A.
Lewandowski, M.
Tasinkevych, Y.
Powiązania:
https://bibliotekanauki.pl/articles/177855.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
synthetic aperture
beamforming
Opis:
Synthetic aperture (SA) technique is a novel approach to present day commercial systems and has previously not been used in medical ultrasound imaging. The basic idea of SA is to combine information acquired simultaneously from all directions over a number of emissions and to reconstruct the full image from these data. The paper presents the multi-element STA (MSTA) method for medical ultrasound imaging. The main difference with the STA approach is the use of a few elements in the transmit mode in contrast to a single element aperture. This allows increasing the system frame rate, decreasing the number of emissions, and provides the best compromise between the penetration depth and lateral resolution. Besides, a modified MSTA is proposed with a corresponding RF signal correction in the receive mode, which accounts for the element directivity property. In the experiments a 32-element linear transducer array with 0.48 mm interelement spacing and a burst pulse of 100 ns duration were used. Two elements wide transmission aperture was used to generate an ultrasound wave covering the full image region. The comparison of 2D ultrasound images of a tissue mimicking phantom obtained using the STA and MSTA methods is presented to demonstrate the benefits of the second one.
Źródło:
Archives of Acoustics; 2010, 35, 4; 687-699
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of the Multi-element Synthetic Transmit Aperture Method for Medical Ultrasound Imaging Applications
Autorzy:
Tasinkevych, Y.
Trots, I.
Nowicki, A.
Lewandowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/177208.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
synthetic aperture
beamforming
Opis:
The paper presents the optimization problem for the multi-element synthetic transmit aperture method (MSTA) in ultrasound imaging applications. The optimal choice of the transmit aperture size is made as a trade-off between the lateral resolution, penetration depth and the frame rate. Results of the analysis obtained by a developed optimization algorithm are presented. The maximum penetration depth and lateral resolution at given depths are chosen as optimization criteria. The results of numerical experiments carried out in MATLAB Ž using synthetic aperture data of point reflectors obtained by the FIELD II simulation program are presented. The visualization of experimental synthetic aperture data of a tissue mimicking phantom and in vitro measurements of the beef liver performed using the SonixTOUCH Research system are also shown.
Źródło:
Archives of Acoustics; 2012, 37, 1; 47-55
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Introduction to Virtual Phased Arrays for Beamforming Applications
Autorzy:
Comesaña, D. F.
Holland, K. R.
Escribano, D. G.
de Bree, H. E.
Powiązania:
https://bibliotekanauki.pl/articles/176345.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beamforming
source localization
virtual phased arrays
measurement techniques
Opis:
Sound localization problems are usually tackled by the acquisition of data from phased microphone arrays and the application of acoustic holography or beamforming algorithms. However, the number of sensors required to achieve reliable results is often prohibitive, particularly if the frequency range of interest is wide. It is shown that the number of sensors required can be reduced dramatically providing the sound field is time stationary. The use of scanning techniques such as “Scan & Paint” allows for the gathering of data across a sound field in a fast and efficient way, using a single sensor and webcam only. It is also possible to characterize the relative phase field by including an additional static microphone during the acquisition process. This paper presents the theoretical and experimental basis of the proposed method to localise sound sources using only one fixed microphone and one moving acoustic sensor. The accuracy and resolution of the method have been proven to be comparable to large microphone arrays, thus constituting the so called “virtual phased arrays”.
Źródło:
Archives of Acoustics; 2014, 39, 1; 81-88
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wave Generation by a Finite Baffle Array in Application to Beam-Forming Analysis
Autorzy:
Tasinkevych, Y.
Powiązania:
https://bibliotekanauki.pl/articles/177857.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phased array
beamforming
mixed boundary value problem
BIS expansion
Opis:
Directional excitation of sound in an aperiodic finite baffle system is analyzed using a method developed earlier in electrostatics. The solution to the corresponding boundary value problem is obtained in the spatial-frequency domain. The acoustic pressure and normal particle velocity distribution in acoustic media can be easily computed by the inverse Fourier transform from their spatial spectra on the baffle plane. The presented method can be used for linear acoustic phased arrays modeling with finite element size and inter-element interactions taken into account. Some illustrative numerical examples presenting the far-field radiation pattern and wavebeam steering are given.
Źródło:
Archives of Acoustics; 2010, 35, 4; 677-686
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Golay Coded Sequences in Synthetic Aperture Imaging Systems
Autorzy:
Trots, I.
Tasinkevych, Y.
Nowicki, A.
Lewandowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/176941.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
synthetic aperture
beamforming
radiation pattern
coded sequences
Golay codes
Opis:
The paper presents the theoretical and experimental study of synthetic transmit aperture (STA) method combined with Golay coded transmission for medical ultrasound imaging applications. The transmission of long waveforms characterized by a particular autocorrelation function allows to increase the total energy of the transmitted signal without increasing the peak pressure. It can also improve signal- to-noise ratio and increase the visualization depth maintaining the ultrasound image resolution. In the work the 128-element linear transducer array with 0.3 mm pitch excited by the 8 and 16-bits Golay coded sequences as well as a one cycle at nominal frequencies 4 MHz were used. The comparison of 2D ultrasound images of the tissue mimicking phantoms is presented to demonstrate the benefits of coded transmission. The image reconstruction was performed using synthetic STA algorithm with transmit and receive signals correction based on a single element directivity function.
Źródło:
Archives of Acoustics; 2011, 36, 4; 913-926
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Digital Signal Processing Approach in Air Coupled Ultrasound Time Domain Beamforming
Autorzy:
Herman, K.
Gudra, T.
Furmankiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/177033.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beamforming
air-coupled ultrasounds
DSP
digital signal processing
bat signals
direction of arrival
Opis:
The work presents the results of experimental study on the possibilities of determining the source of an ultrasonic signal in two-dimensional space (distance, horizontal angle). During the research the team used a self-constructed linear array of MEMS microphones. Knowledge in the field of sonar systems was utilized to analyse and design a location system based on a microphone array. Using the above mentioned transducers and broadband ultrasound sources allows a quantitative comparison of estimation of the location of an ultrasonic wave source with the use of broadband modulated signals (modelled on bats’ echolocation signals) to be performed. During the laboratory research the team used various signal processing algorithms, which made it possible to select an optimal processing strategy, where the sending signal is known.
Źródło:
Archives of Acoustics; 2014, 39, 1; 37-50
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Circular Radon Transform Inversion Technique in Synthetic Aperture Ultrasound Imaging : an Ultrasound Phantom Evaluation
Autorzy:
Tasinkevych, J.
Trots, I.
Powiązania:
https://bibliotekanauki.pl/articles/176632.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
synthetic aperture focusing method
circular Radon Transform
delay and sum beamforming
range migration algorithm
Opis:
The paper presents an overview of theoretical aspects of ultrasound image reconstruction techniques based on the circular Radon transform inversion. Their potential application in ultrasonography in a similar way as it was successfully done in the x-ray computer tomography is demonstrated. The meth- ods employing Radon transform were previously extensively explored in the synthetic aperture radars, geophysics, and medical imaging using x-ray computer tomography. In this paper the main attention is paid to the ultrasound imaging employing monostatic transmit-receive configuration. Specifically, a single transmit and receive omnidirectional source placed at the same spatial location is used for generation of a wide-band ultrasound pulse and detection of back-scattered waves. The paper presents derivation of the closed-form solution of the CRT inversion algorithms by two different approaches: the range-migration algorithm (RMA) and the deconvolution algorithm (DA). Experimentally determined data of ultrasound phantom obtained using a 32-element 5 MHz linear transducer array with 0.48 mm element pitch and 0.36 mm element width and 5 mm height, excited by a 2 sine cycles burst pulse are used for comparison of images reconstructed by the RMA, DA, and conventional synthetic aperture focusing technique (SAFT). It is demonstrated that both the RMA and SAFT allow better lateral resolution and visualization depth to be achieved as compared to the DA approach. Comparison of the results obtained by the RMA method and the SAFT indicates slight improvement of the lateral resolution for the SAFT of approximately 1.5 and 1.6% at the depth of 12 and 32 mm, respectively. Concurrently, however, the visualization depth increase for the RMA is shown in comparison with the SAFT. Specifically, the scattered echo amplitude increase by the factor of 1.36 and 1.12 at the depth of 22 and 32 mm is demonstrated. It is also shown that the RMA runs about 30% faster than the SAFT and about 12% faster than the DA method.
Źródło:
Archives of Acoustics; 2014, 39, 4; 569-582
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance Analysis of MVDR Beamformer Applied on an End-fire Microphone Array Composed of Unidirectional Microphones
Autorzy:
Šarić, Zoran
Subotić, Miško
Bilibajkić, Ružica
Barjaktarović, Marko
Zdravković, Nebojša
Powiązania:
https://bibliotekanauki.pl/articles/2141702.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adaptive beamforming
ambient noise suppression
differential microphone array
end-fire microphone array
MVDR beamformer
Opis:
Microphone array with minimum variance (MVDR) beamformer is a commonly used method for ambient noise suppression. Unfortunately, the performance of the MVDR beamformer is poor in a real reverberant room due to multipath wave propagation. To overcome this problem, we propose three improvements. Firstly, we propose end-fire microphone array that has been shown to have a better directivity index than the corresponding broadside microphone array. Secondly, we propose the use of unidirectional microphones instead of omnidirectional ones. Thirdly, we propose an adaptation of its adaptive algorithm during the pause of speech, which improves its robustness against the room reverberation and deviation from the optimal receiving direction. The performance of the proposed microphone array was theoretically analyzed using a diffuse noise model. Simulation analysis was performed for combined diffuse and coherent noise using the image model of the reverberant room. Real room tests were conducted using a four-microphone array placed in a small office room. The theoretical analysis and the real room tests showed that the proposed solution considerably improves speech quality.
Źródło:
Archives of Acoustics; 2021, 46, 4; 611-621
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies