Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wójcik, A.J." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Example of Structure Modeling and Analysis of Ultrasound Scattering for Trabecular Bone
Autorzy:
Wójcik, J.
Litniewski, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177853.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-scattering
random complex structures
trabecular bone model
Opis:
A trabecular bone consists of trabeculae whose mechanical properties differ significantly from the surrounding marrow, therefore an ultrasonic wave propagating within the bone structure is strongly scattered. The aim of this paper was to evaluate the contribution of the first, second and higher order scattering (multiple scattering) into the total scattering of ultrasound in a trabecular bone. The scattering due to the interconnections between thick trabeculae, usually neglected in trabecular bone models, has been also studied. The basic element in our model of the trabecular bone was an elastic cylinder with a various finite-length and diameter as well as orientation. The applied model was taking into account variation of both, elements size and their spatial configuration. The field scattered on the bone model was evaluated by solving numerically the integral form of the generalized Sturm-Liouville equation describing a scalar wave in inhomogeneous and lossy media. For the scattered fields calculated numerically the effective cross-sections were determined. The influence of absorption on the scattering coefficients was demonstrated. The results allowed to conclude that within the frequency range from 0.5 to 1.5 MHz contribution of the second order scattering to the effective backscattering cross-section is at least 500 times lower than that due to the first order scattering. It was noticed that for a frequency higher than 1.5 MHz fast growth of the backscattering (reflection) coefficients, calculated for the second order scattering, occurs.
Źródło:
Archives of Acoustics; 2010, 35, 4; 701-713
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Empirical Mode Decomposition of Backscattered Ultrasound Signal Power Spectrum for Assessment of Tissue Compression
Autorzy:
Byra, M.
Wójcik, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177950.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tissue characterization
tissue compression
quantitative ultrasound
empirical mode decomposition
signal analysis
Opis:
Quantitative ultrasound has been widely used for tissue characterization. In this paper we propose a new approach for tissue compression assessment. The proposed method employs the relation between the tissue scatterers’ local spatial distribution and the resulting frequency power spectrum of the backscattered ultrasonic signal. We show that due to spatial distribution of the scatterers, the power spectrum exhibits characteristic variations. These variations can be extracted using the empirical mode decomposition and analyzed. Validation of our approach is performed by simulations and in-vitro experiments using a tissue sample under compression. The scatterers in the compressed tissue sample approach each other and consequently, the power spectrum of the backscattered signal is modified. We present how to assess this phenomenon with our method. The proposed in this paper approach is general and may provide useful information on tissue scattering properties.
Źródło:
Archives of Acoustics; 2018, 43, 3; 447-453
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical and Ultrasonographic Model of the Left Ventricle : in Vitro Studies
Autorzy:
Olszewski, R.
Trawiński, Z.
Wójcik, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/176705.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
left ventricle
echocardiography
speckle modeling
ultrasound phantoms
strain
strain rate
Opis:
The main objective of this study is to develop an echocardiographic model of the left ventricular and numerical modeling of the speckles- markers tracking in the ultrasound (ultrasonographic) imaging of the left ventricle. The work is aimed at the creation of controlled and mobile environment that enables to examine the relationships between left ventricular wall deformations and visualizations of these states in the form of echocardiographic imaging and relations between the dynamically changing distributions of tissue markers of studied structures.
Źródło:
Archives of Acoustics; 2012, 37, 4; 583-595
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound
Autorzy:
Secomski, W.
Nowicki, A.
Wójcik, J.
Lewandowski, M.
Walczak, M.
Tymkiewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/177840.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic therapy
annular array transducer
ultrasonic field
Opis:
The use of therapeutic ultrasound continues to grow. A focused ultrasonic wave can increase the tissue temperature locally for the non-invasive cancer treatment or other medical applications. The authors have designed a seven-element annular array transducer operating at 2.4 MHz. Each element was excited by sine burst supplied by a linear amplifier and FPGA control circuits. The acoustic field, generated by a transducer was initially numerically simulated in a computer and next compared to water tank hydrophone measurements performed at 20, 40 and 60 mm focal depth. The results showed good agreement of the measurements with theory and the possibility to focus the ultrasound in the preselected area. The total acoustic power radiated by the annular array was equal to 2.4 W.
Źródło:
Archives of Acoustics; 2010, 35, 4; 653-660
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thick Film Transducers for High Frequency Coded Ultrasonography
Autorzy:
Nowicki, A.
Lewandowski, M.
Wójcik, J.
Tymkiewicz, R.
Lou-Moller, R.
Wolny, W.
Zawada, T.
Powiązania:
https://bibliotekanauki.pl/articles/176939.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
transducers
thick film
high frequency ultrasound
pulse compression
Golay codes
Opis:
Recently a new technology of piezoelectric transducers based on PZT thick film has been developed as a response to a call for devices working at higher frequencies suitable for production in large numbers at low cost. Eight PZT thick film based focused transducers with resonant frequency close to 40 MHz were fabricated and experimentally investigated. The PZT thick films were deposited on acoustically engineered ceramic substrates by pad printing. Considering high frequency and nonlinear propagation it has been decided to evaluate the axial pressure field emitted (and reflected by thick metal plate) by each of concave transducer differing in radius of curvature – 11 mm, 12 mm, 15 mm, 16 mm. All transducers were activated using AVTEC AVG-3A-PS transmitter and Ritec diplexer connected directly to Agilent 54641D oscilloscope. As anticipated, in all cases the focal distance was up to 10% closer to the transducer face than the one related to the curvature radius. Axial pressure distributions were also compared to the calculated ones (with the experimentally determined boundary conditions) using the angular spectrum method including nonlinear propagation in water. The computed results are in a very good agreement with the experimental ones. The trans- ducers were excited with Golay coded sequences at 35–40 MHz. Introducing the coded excitation allowed replacing the short-burst transmission at 20 MHz with the same peak amplitude pressure, but with almost double center frequency, resulting in considerably better axial resolution. The thick films exhibited at least 30% bandwidth broadening comparing to the standard PZ 27 transducer, resulting in an increase in matching filtering output by a factor of 1.4–1.5 and finally resulting in a SNR gain of the same order.
Źródło:
Archives of Acoustics; 2011, 36, 4; 945-954
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies