Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ozimek" wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
Logatome and Sentence Recognition Related to Acoustic Parameters of Enclosures
Autorzy:
Kociński, J.
Ozimek, E.
Powiązania:
https://bibliotekanauki.pl/articles/176289.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
STI
Speech Transmission Index
speech intelligibility
reverberation time
Opis:
The paper deals with relationship between speech recognition and objective parameters of enclosures. Six enclosures were chosen: a church, an assembly hall of a music school, two courtrooms of different volumes, a typical auditorium and a university concert hall. Dirac 4.1 software was used to record impulse responses (IRs) in the chosen measurement points of each enclosure. On this base, the following objective parameters of the enclosure were determined: Reverberation Time (RT), Early Decay Time (EDT), Weighted Clarity (C50) and Speech Transmission Index (STI). A convolution of the IRs with logatome tests and the Polish Sentence Test (PST) was made. Logatome recognition and speech reception threshold (SRT – i.e., SNR yielding 50% speech recognition) were evaluated and their dependence on the objective parameters were determined. Generally a linear relationship between logatome or SRT and RT or EDT was found. However, speech recognition was nonlinearly related (according to psychometric function) to STI values. The most sensitive range of the logatome and sentence recognition relative to STI changes corresponded to the middle range of STI values. Below and above this range, logatome and sentence recognition were much less dependent of STI changes.
Źródło:
Archives of Acoustics; 2017, 42, 3; 385-394
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in Distortion Product Otoacoustic Emission Caused by Contralateral Broadband Noise
Autorzy:
Ozimek, E.
Wicher, A.
Powiązania:
https://bibliotekanauki.pl/articles/177139.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distortion product otoacoustic emissions
DPOAEs
contralateral acoustic stimulation
CAS
contralateral suppression
Opis:
The main purpose of this investigation was to measure the effect of contralateral acoustic stimulation (CAS) on distortion product otoacoustic emission (DPOAE) in twenty human ears, for a ratio of primary tones f2/f1 = 1.22 and a wide frequency range of f2 (1.4–9 kHz), for two intensity levels of primary tones (L1 = 60 dB SPL; L2 = 50 dB SPL and L1 = 70 dB SPL; L2 = 60 dB SPL) and two intensity levels of CAS (50 and 60 dB SPL). It was found that in the presence of CAS, in the majority of cases the DPOAE level decreased (suppression), but it might also increase (enhancement) or remain unchanged depending on the frequency. The mean suppression level of the component of the frequency fDP = 2f1 − f2 might be approximated by a linearly decreasing function of the f2 frequency of primary tones. The slope of this function was negative and increased with an increase of the contralateral stimulation level. The higher was the contralateral noise level the greater was the suppression. For the fDP level below about 15 dB SPL, suppression was observed in a substantial number of measurement cases (in about 85% of all measured cases on average). When the fDP level was higher than 15 dB SPL, only suppression (not enhancement) was observed.
Źródło:
Archives of Acoustics; 2014, 39, 1; 125-138
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Speech Recognition in an Enclosure with a Long Reverberation Time
Autorzy:
Kociński, J.
Ozimek, E.
Powiązania:
https://bibliotekanauki.pl/articles/177544.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
speech intelligibility
speech recognition
sentence test
reverberation time
clarity
speech transmission index
Opis:
The aim of this work was to measure subjective speech intelligibility in an enclosure with a long reverberation time and comparison of these results with objective parameters. Impulse Responses (IRs) were first determined with a dummy head in different measurement points of the enclosure. The following objective parameters were calculated with Dirac 4.1 software: Reverberation Time (RT), Early Decay Time (EDT), weighted Clarity (C50) and Speech Transmission Index (STI). For the chosen measurement points, a convolution of the IRs with the Polish Sentence Test (PST) and logatome tests was made. PST was presented at a background of a babble noise and speech reception threshold – SRT (i.e. SNR yielding 50% speech intelligibility) for those points were evaluated. A relationship of the sentence and logatome recognition vs. STI was determined. It was found that the final SRT data are well correlated with speech transmission index (STI), and can be expressed by a psychometric function. The difference between SRT determined in condition without reverberation and in reverberation conditions appeared to be a good measure of the effect of reverberation on speech intelligibility in a room. In addition, speech intelligibility, with and without use of the sound amplification system installed in the enclosure, was compared.
Źródło:
Archives of Acoustics; 2016, 41, 2; 255-264
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Speech Intelligibility in Rooms with and without an Induction Loop for Hearing Aid Users
Autorzy:
Kociński, J.
Ozimek, E.
Powiązania:
https://bibliotekanauki.pl/articles/177905.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
speech intelligibility
induction loop
hearing impairment
speech enhancement
Opis:
The paper presents the results of sentence and logatome speech intelligibility measured in rooms with induction loop for hearing aid users. Two rooms with different acoustic parameters were chosen. Twenty two subjects with mild, moderate and severe hearing impairment using hearing aids took part in the experiment. The intelligibility tests composed of sentences or logatomes were presented to the subjects at fixed measurement points of an enclosure. It was shown that a sentence test is more useful tool for speech intelligibility measurements in a room than logatome test. It was also shown that induction loop is very efficient system at improving speech intelligibility. Additionally, the questionnaire data showed that induction loop, apart from improving speech intelligibility, increased a subject’s general satisfaction with speech perception.
Źródło:
Archives of Acoustics; 2015, 40, 1; 51-58
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies