Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "(mt)" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Clinical factors affecting the perception of hypoglycemia in type 1 diabetes patients treated with personal insulin pumps
Autorzy:
Matejko, B.
Grzanka, M.
Kiec-Wilk, B.
Malecki, M.T.
Klupa, T.
Powiązania:
https://bibliotekanauki.pl/articles/52037.pdf
Data publikacji:
2013
Wydawca:
Instytut Medycyny Wsi
Opis:
Introduction and Objective. The ability to perceive the symptoms of hypoglycemia during the early decrease in plasma glucose concentration may be critical for the safety of T1DM patients treated with intensive insulin therapy, including those treated with continuous subcutaneous insulin infusion (CSII). In the presented observational study an attempt was made to asses clinical factors that might affect subjective awareness of hypoglycemia in CSII-treated T1DM patients, with special attention to factors specific for this mode of treatment. Materials and Methods. For the purpose of the study, data of 110 CSII-treated T1DM patients were collected (78 females and 32 males). The records were analyzed from glucose meters (200-300 measurements/download, depending on meter type) and insulin pumps (total insulin dose, basal/bolus ratio, number of boluses/day, bolus calculator and dual wave/square bolus usage, continuous glucose monitoring data) from the last 3 years. Results. It was found that the level of subjective hypoglycemia perception inversely correlated with the number of hypoglycemic episodes per 100 measurements, age, duration of diabetes, time on insulin pump, and positively correlated with mean glycemia (n = 98; r = 0.22; p = 0.0286). With respect to CSII-related factors, hypoglycemia perception inversely correlated with the percentage of basal insulin (n = 106; r = -0.20; p = 0.0354). In stepwise regression analysis, independent predictors for impaired hypoglycemia perception were: age β = -0.29 (p = 0.023), duration of diabetes β = -0.24 (p = 0.029) and number of the hypoglycemia episodes for 100 measurements β = -0.33 (p = 0.0005). Conclusions. Risk factors for impaired hypoglycemia perception in CSII-treated patients include those identified previously for the general population of T1DM individuals. In addition, the presented results suggest that a higher basal/bolus ratio may lead to impairment of the ability to perceive early symptoms of hypoglycemia.
Źródło:
Annals of Agricultural and Environmental Medicine; 2013, 20, 1
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficacy and safety of insulin pump treatment in adult T1DM patients – influence of age and social environment
Autorzy:
Grzanka, M.
Matejko, B.
Cyganek, K.
Kozek, E.
Malecki, M.T.
Klupa, T.
Powiązania:
https://bibliotekanauki.pl/articles/51359.pdf
Data publikacji:
2012
Wydawca:
Instytut Medycyny Wsi
Opis:
Introduction and objective. Continuous subcutaneous insulin infusion (CSII) via personal insulin pump is a valuable therapeutic tool in T1DM patients. However, adherence to recommended CSII- related behaviours may be of concern to young adults with intensive, variable daily activities (students, young professionals). The aim of this observational study was to estimate treatment outcomes in young adult patients with T1DM, and compare them with older individuals. Materials and methods. Overall, 140 adults with T1DM on CSII were examined, divided into 2 subgroups: 77 patients younger than 26 years of age (mean 20.6 years) and 63 older subjects (mean 39.0). We compared the glycaemic control in both groups of T1DM subjects and analyzed treatment attitudes to identify potentially modifiable behaviours influencing the efficacy of the treatment. Results. The younger individuals were characterized by significantly worse treatment outcomes, compared to the older ones: the mean HbA1c levels were 7.6 ± 1.3% and 6.9±1.3% (p=0.00001), while the mean glucose levels based on glucometer downloads were 161±33.6 mg/dL and 136±21.8 mg/dL (p=0.00001), respectively. The frequency of self-monitoring of blood glucose (SMBG) was lower in younger individuals (5.3±2.1 vs. 7.0±2.8 daily, p=0.0005, respectively); they were also less frequently used advanced pump functions, e.g. the bolus calculator (48% vs. 67% users, p=0.0014, respectively). Conclusions. The efficacy of CSII treatment observed in young T1DM adults was worse than in older patients. The reason for this phenomenon remains unclear, it may be due simply to age-dependend behaviours, to social environment, or both.
Źródło:
Annals of Agricultural and Environmental Medicine; 2012, 19, 3
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chronic respiratory symptoms of poultry farmers and model-based estimates of long-term dust exposure
Autorzy:
Guillam, M.T.
Pedrono, G.
Le Bouquin, S.
Huneau, A.
Gaudon, J.
Leborgne, R.
Dewitte, J.D.
Segala, C.
Powiązania:
https://bibliotekanauki.pl/articles/51420.pdf
Data publikacji:
2013
Wydawca:
Instytut Medycyny Wsi
Tematy:
chronic respiratory disease
poultry farm
farmer
long-term exposure
dust exposure
occupational exposure
respirable dust
task
environment monitoring
chronic bronchitis
bronchitis
human disease
occupational disease
Opis:
Objectives. The airborne contaminant exposure levels experienced by poultry farmers have raised concerns about the possible health hazards associated with them. Thus, a longitudinal project was instituted in France to monitor these exposures in poultry workers and to evaluate the long-term effect on health. Method. Sixty-three workers in two different poultry housing systems were included (33 from floor-based systems and 30 from cage-based systems). Personal dust concentrations (over 2 days) and activity patterns (over 14 days) were collected and then modeled to obtain average long-term estimates. Health data were collected by questionnaire. Results. The mean daily time spent in the cage system was more than 2 hours longer than in the floor system. Two main common tasks accounted for ~70% of this time. Dust concentrations were higher in the floor system than in the cage system. The concentrations for the 14 days of known activity patterns estimated using the statistical model agreed well with the measured values. Several chronic respiratory symptoms were significantly associated with the high levels of long-term exposure estimated by the model. The highest risk was for chronic bronchitis symptoms (>4-fold higher for exposures of 0.1 mg/m3 of respirable dust). Conclusion. The presented modeling strategy can be used to estimate the long-term average personal exposure to respirable dust, and to study the association between dust exposure and chronic respiratory symptoms. This population of workers will be followed-up in subsequent examinations (3 years later) to determine whether the predictive model is valid, and whether long-term dust exposure is related to the incidence of respiratory symptoms and changes in pulmonary functions.
Źródło:
Annals of Agricultural and Environmental Medicine; 2013, 20, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Toxoplasma gondii in small ruminants in Northern Italy – prevalence and risk factors
Autorzy:
Gazzonis, A.L.
Veronesi, F.
Di Cerbo, A.R.
Zanzani, S.A.
Molineri, G.
Moretta, I.
Moretti, A.
Fioretti, D.P.
Invernizzi, A.
Manfredi, M.T.
Powiązania:
https://bibliotekanauki.pl/articles/51428.pdf
Data publikacji:
2015
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2015, 22, 1
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies