Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ostrowska, J." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Determination of operator’s impact on the measurement done using coordinate technique
Autorzy:
Ostrowska, K.
Szewczyk, D.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102406.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
R&R method
coordinate measuring arms (CMA)
operator impact
repeatability
reproducibility
Opis:
Coordinate measuring arms (CMAs) are devices which more and more often replace conventional coordinate measuring machines because of their undoubted advantages, such as mobility, the opportunity to increase the measuring volume, the opportunity to connect the optical probe, and above all, good price-quality ratio. Because these devices are handheld and redundant, what has the greatest impact on the measurement result accuracy are the operator, the machine kinematics and its ability to obtain repeatable measurement results; despite the fact that one point can be obtained from an infinite number of shoulders’ positions. In this paper it was determined by using R&R method how significant are the impacts of both the operator and the measuring device on the accuracy of measurements done with CMA, both with rigid switch probe and optical probe.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 20; 11-16
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of measurement uncertainty with the use of uncertainty database calculated for optical coordinate measurements of basic geometry elements
Autorzy:
Owczarek, D.
Ostrowska, K.
Harmatys, W
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/101965.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
estimation of measurement uncertainty
optical coordinate measuring systems
Opis:
The paper presents a method for estimating the uncertainty of optical coordinate measurement based on the use of information about the geometry and the size of measured object as well as information about the measurement system, i.e. maximum permissible error (MPE) of the machine, selection of a sensor, and also the required measurement accuracy, the number of operators, measurement strategy and external conditions contained in the developed uncertainty database. Estimation of uncertainty is done with the use of uncertainties of measurements of basic geometry elements determined by methods available in the Laboratory of Coordinate Metrology at Cracow University of Technology (LCM CUT) (multi-position, comparative and developed in the LCM CUT method dedicated for non-contact measurements) and then with the use of them to determine the uncertainty of a given measured object. Research presented in this paper are aimed at developing a complete database containing all information needed to estimate the measurement uncertainty of various objects, even of a very complex geometry based on previously performed measurements.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 27; 112-117
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Validation of the metrological model of coordinate measuring arm using multifeature check
Autorzy:
Gromczak, K.
Ostrowska, K.
Owczarek, D.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/957962.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
validation
metrological model
coordinate measuring arms
Opis:
The article presents the validation research scheme of metrological model of coordinate measuring arm (CMA) using multifeature check. The scheme shows the comparison of the calibration results of the check using selected coordinate methods and criteria of validation. The comparison shows the insignificance of differences between the obtained results of both: metrological model of CMA and multi-position method. It evidently proves the correctness of the development of metrological model of CMA. The use of appropriate quality multifeature check also had a significant impact on the results. This check is now the most accurate measurement length check and its use for this validation process was the most suitable.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 28; 120-124
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies