Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tętnica" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Mechanical guidelines on the properties of human healthy arteries in the design and fabrication of vascular grafts: experimental tests and quasi-linear viscoelastic model
Autorzy:
Faturechi, Rahim
Hashemi, Ata
Abolfathi, Nabiollah
Solouk, Atefeh
Powiązania:
https://bibliotekanauki.pl/articles/307007.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
elastyczność
model konstytutywny
tętnica
elasticity
constitutive model
human artery
artificial artery
quasi-linear viscoelasticity
Opis:
Knowledge of mechanical behavior of healthy human arteries as the guidelines to target properties of vascular grafts deserves special attention. There is a lack of mathematical model to characterize mechanical behavior of biomaterial while many mathematical models to reflect mechanics of human arteries have been proposed. The objective of this paper was set to measure mechanical properties of healthy human arteries including Common Carotid Artery (CCA), Abdominal Aorta Artery (AAA), Subclavian Artery (SA), Common Iliac Artery (CIA) and Right and Left Iliac Artery (RIA and LIA) and compare them to those of commercial ePTFE and Dacron®. Methods: Series of stress relaxation and strain to failure tests vere performed on all samples. The experimental data was utilized to develop quasi-linear viscoelastic (QLV) model of both natural and artificial arteries. Results: ePTFE is the stiffest sample, while the CCA is the most compliant one among all. RIA and CIA are more viscous than the other natural arteries, while AA and CCA are less viscous. The proposed model demonstrated an accurate fit to the experimental results, a proof of its ability to model both nonlinear elasticity and viscoelasticity of the human arteries and commercial ones. Conclusions: ePTFE and Dacron® are much stiffer than human arteries that may lead to the disruption of blood hemodynamic and may not be biomechanically feasible as a replacement.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 3; 13-21
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hemodynamic impacts of left coronary stenosis : a patient-specific analysis
Autorzy:
Chaichana, T.
Sun, Z.
Jewkes, J.
Powiązania:
https://bibliotekanauki.pl/articles/306747.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
coronary artery disease
computational fluid dynamics (CFD)
wall shear stress
tętnica wieńcowa
dynamika cieczy
naprężenie
Opis:
This study analyses the hemodynamic variations surrounding stenoses located at the left coronary bifurcation, and their influence on the wall shear stress (WSS) in realistic coronary geometries. Four patients with suspected coronary artery disease were chosen, and coronary models were reconstructed based on high-resolution CT data. The coronary stenoses were observed at the left circumflex and left anterior descending branches, resulting in a lumen narrowing of >50%. Flow analysis was performed using computational fluid dynamics, to simulate the cardiac flow conditions of the realistic individual patient geometry. Blood flow and WSS changes in the left coronary artery were calculated throughout the entire cardiac phases. Our results revealed that the recirculation regions were found at the poststenotic locations. WSS was found to increase at the stenotic positions in all four patients. There is a strong correlation between coronary stenosis and the hemodynamic changes, which are reflected in blood flow pattern and WSS, based on the realistic left coronary geometries.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 3; 107-111
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical and experimental analysis of balloon angioplasty impact on flow hemodynamics improvement
Autorzy:
Tomaszewski, Michał
Sybilski, Kamil
Małachowski, Jerzy
Wolański, Wojciech
Buszman, Piotr P.
Powiązania:
https://bibliotekanauki.pl/articles/27324133.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
angioplasty
stent
artery
hemodynamics
cfd analysis
PIV method
angioplastyka
tętnica
hemodynamika
analiza CFD
metoda PIV
Opis:
Purpose: The paper focuses on the numerical and experimental evaluation of the fluid flow inside chosen fragments of blood vessels. In the first stage of the study, the experimental tests were conducted using a research test stand, designed to be used in this evaluation. The study evaluated the blood flow through a silicone vessel with an implanted coronary stent. Methods: The PIV method was used in order to visualize the flow vectors inside a silicone vessel. Deformed vessel geometry implemented for computational fluid dynamics purposes was obtained owing to a non-linear simulation of the stent expansion (angioplasty process) in a silicone vessel. Additionally, a vessel model with a statistical 55% area stenosis and an irregular real vessel with an atherosclerotic plaque were also subjected to analysis from the hemodynamic flow point of view. A vessel with a statistical stenosis was also used to simulate the angioplasty process, which resulted in obtaining a flow domain for the vessel with an atherosclerotic plaque after the stent implantation. Results: For each case, distributions of parameters such as OSI or TAWSS were also analyzed and discussed. The areas of low TAWSS values appear close to the stent struts. Conclusions: Stents with increased diameters, compared to the normal vessel diameter, create a higher risk of occurrence of the areas with low WSS values. Excessive stent deformation can cause inflammation by injuring the vessel and can initiate the restenosis and thrombotic phenomena through the increased vessel diameter.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 169--183
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of blood flow rheology using second-grade viscoelastic model (Phan-Thien–Tanner) within carotid artery
Autorzy:
Ramiar, A.
Larimi, M. M.
Ranjbar, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/307522.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tętnica szyjna
model lepkoplastyczny
przepływ pulsujący
naprężenie ścinające
OpenFOAM
carotid artery
viscoelastic model
pulsatile flow
shear stress
Opis:
Purpose: Hemodynamic factors, such as Wall Shear Stress (WSS), play a substantial role in arterial diseases. In the larger arteries, such as the carotid artery, interaction between the vessel wall and blood flow affects the distribution of hemodynamic factors. The fluid is considered to be non-Newtonian, whose flow is governed by the equation of a second-grade viscoelastic fluid and the effects of viscoelastic on blood flow in carotid artery is investigated. Methods: Pulsatile flow studies were carried out in a 3D model of carotid artery. The governing equations were solved using finite volume C++ based on open source code, OpenFOAM. To describe blood flow, conservation of mass and momentum, a constitutive relation of simplified Phan-Thien–Tanner (sPTT), and appropriate relations were used to explain shear thinning behavior. Results: The first recirculation was observed at t = 0.2 s, in deceleration phase. In the acceleration phase from t = 0.3 s to t = 0.5 s, vortex and recirculation sizes in bulb regions in both ECA and ICA gradually increased. As is observed in the line graphs based on extracted data from ICA, at t = 0.2 s, τyy is the maximum amount of wall shear stress and τxy the minimum one. The maximum shear stress occurred in the inner side of the main branch (inner side of ICA and ECA) because the velocity of blood flow in the inner side of the bulb region was maximum due to the created recirculation zone in the opposite side in this area. Conclusions: The rheology of blood flow and shear stress in various important parts (the area that are in higher rates of WSS such as bifurcation region and the regions after bulb areas in both branches, Line1–4 in Fig. 7) were also analyzed. The investigation of velocity stream line, velocity profile and shear stress in various sections of carotid artery showed that the maximum shear stress occurred in acceleration phase and in the bifurcation region between ECA and ICA which is due to velocity gradients and changes in thinning behavior of blood and increasing strain rate in Newtonian stress part.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 3; 27-41
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies