Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "material engineering" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Remodelling of material structure in aortic valve leaflet
Autorzy:
Patralski, K.
Konderla, P.
Powiązania:
https://bibliotekanauki.pl/articles/951815.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
aorta
inżynieria tkankowa
przebudowa struktury
aortic valve
tissue engineering
fibre reinforced material
remodelling
Opis:
Purpose: The goal of this study is to model changes in fibre content in aortic valve leaflet material due to mechanical stimuli. Methods: The fibre remodelling process is associated with the redistribution of the internal forces acting in the shell. The process is characterized by the occurrence of extreme stresses and strains. The load distribution function is asymmetrical. The optimization problem has been assigned the task of transferring the load imposed on the leaflet. The density of the fibres per unit surface of the middle shell was assumed to be proportional to the shell thickness, which means that fibre density along the normal direction is constant over the entire shell. Results: The model of valve leaflet loading is the distribution of the pressure generated on the leaflet shell surface by the flowing fluid. The algorithm for the redistribution of the leaflet material mass made it possible to distinguish two regions of enhanced thickness in the leaflet shell. One was localized between the commissures along the leaflet attachment, the other one in the middle part of the leaflet at the level of the commissures. A reduction in shell thickness is observed in the middle part of the leaflet, above the point of its attachment to the aorta. Conclusions: The distribution of the thickness field obtained corroborates the findings of the study reported elier. Our study on the remodelling of the valve leaflet entailed the application of the stress criterion, which visibly upgraded the functioning of the valve by improving its mechanical and hemodynamic parameters.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 2; 63-72
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies